hwmon: (lm70) Fix rounding of negative temperatures
temp1_input_show() drops the low bits of the temperature register by dividing the raw value (raw / 32 on the LM70). These bits are not part of the temperature: the LM70, LM71, LM74 and TMP122/TMP124 always return some of them as 1, and the TMP125 fills them with copies of the temperature LSB. Division rounds toward zero, so a negative temperature with any of these bits set is reported one LSB too high. For example, the TMP122 returns 0xffff for -0.0625 degrees C, which the driver reports as 0. The LM70 returns 0xf39f for -25 degrees C, which the driver reports as -24750. Use an arithmetic right shift instead, which drops the low bits and rounds down. Fixes: e1a8e913f97e ("[PATCH] lm70: New hardware monitoring driver") Fixes: a86e94dc946d ("hwmon: (lm70) Add support for LM71 and LM74") Fixes: cd929672a9ef ("hwmon: (lm70) Add ti,tmp125 support") Cc: stable@vger.kernel.org Signed-off-by: Ridham Khurana <khurana.ridham222@gmail.com> Link: https://patch.msgid.link/20260924205326.1739229-1-khurana.ridham222@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>