be2net: increment work_counter in be_worker

The commit 609ff3b ("be2net: add code to display temperature of ASIC")
adds support to display temperature of ASIC but there is missing
increment of work_counter in be_worker. Because of this 1) the
function be_cmd_get_die_temperature is called every 1 second instead
of every 32 seconds 2) be_cmd_get_die_temperature is called, although
it is not supported. This patch fixes this bug.

Signed-off-by: Ivan Vecera <ivecera@redhat.com>
Signed-off-by: David S. Miller <davem@davemloft.net>

authored by Ivan Vecera and committed by David S. Miller e74fbd03 e965c05d

+1
+1
drivers/net/benet/be_main.c
··· 1873 be_detect_dump_ue(adapter); 1874 1875 reschedule: 1876 schedule_delayed_work(&adapter->work, msecs_to_jiffies(1000)); 1877 } 1878
··· 1873 be_detect_dump_ue(adapter); 1874 1875 reschedule: 1876 + adapter->work_counter++; 1877 schedule_delayed_work(&adapter->work, msecs_to_jiffies(1000)); 1878 } 1879