bloat-o-meter: include read-only data section in report

I'm not sure why the read-only data section is excluded from the report,
it seems as relevant as the other data sections (b and d).

I've stripped the symbols starting with __mod_ as they can have their
names dynamically generated and thus comparison between binaries is not
possible.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Andi Kleen <andi@firstfloor.org>
Acked-by: Nathan Lynch <ntl@pobox.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>

authored by Jean Delvare and committed by Linus Torvalds c50e3f51 565d76cb

+3 -1
+3 -1
scripts/bloat-o-meter
··· 17 17 sym = {} 18 18 for l in os.popen("nm --size-sort " + file).readlines(): 19 19 size, type, name = l[:-1].split() 20 - if type in "tTdDbB": 20 + if type in "tTdDbBrR": 21 + # strip generated symbols 22 + if name[:6] == "__mod_": continue 21 23 # function names begin with '.' on 64-bit powerpc 22 24 if "." in name[1:]: name = "static." + name.split(".")[0] 23 25 sym[name] = sym.get(name, 0) + int(size, 16)