Documentation/3c509: document ethtool support

3c509 was changed to support ethtool in 2002, making the 'xcvr' module
parameter obsolete in most cases. More recently 3c509 was converted
to the modern driver model and this parameter was removed. Fix the
documentation to refer to ethtool rather than the module parameter.

Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>

authored by Ben Hutchings and committed by David S. Miller aa4e2e17 eb70df13

+8 -4
+8 -4
Documentation/networking/3c509.txt
··· 48 This configures the first found 3c509 card for IRQ 10, base I/O 0x310, and 49 transceiver type 3 (10base2). The flag "0x3c509" must be set to avoid conflicts 50 with other card types when overriding the I/O address. When the driver is 51 - loaded as a module, only the IRQ and transceiver setting may be overridden. 52 - For example, setting two cards to 10base2/IRQ10 and AUI/IRQ11 is done by using 53 - the xcvr and irq module options: 54 55 - options 3c509 xcvr=3,1 irq=10,11 56 57 58 (2) Full-duplex mode ··· 77 itself full-duplex capable. This is almost certainly one of two things: a full- 78 duplex-capable Ethernet switch (*not* a hub), or a full-duplex-capable NIC on 79 another system that's connected directly to the 3c509B via a crossover cable. 80 81 /////Extremely important caution concerning full-duplex mode///// 82 Understand that the 3c509B's hardware's full-duplex support is much more ··· 115 never automatically enable full-duplex mode in an existing installation; 116 it must always be explicitly enabled via one of these code in order to be 117 activated. 118 119 120 (4a) Interpretation of error messages and common problems
··· 48 This configures the first found 3c509 card for IRQ 10, base I/O 0x310, and 49 transceiver type 3 (10base2). The flag "0x3c509" must be set to avoid conflicts 50 with other card types when overriding the I/O address. When the driver is 51 + loaded as a module, only the IRQ may be overridden. For example, 52 + setting two cards to IRQ10 and IRQ11 is done by using the irq module 53 + option: 54 55 + options 3c509 irq=10,11 56 57 58 (2) Full-duplex mode ··· 77 itself full-duplex capable. This is almost certainly one of two things: a full- 78 duplex-capable Ethernet switch (*not* a hub), or a full-duplex-capable NIC on 79 another system that's connected directly to the 3c509B via a crossover cable. 80 + 81 + Full-duplex mode can be enabled using 'ethtool'. 82 83 /////Extremely important caution concerning full-duplex mode///// 84 Understand that the 3c509B's hardware's full-duplex support is much more ··· 113 never automatically enable full-duplex mode in an existing installation; 114 it must always be explicitly enabled via one of these code in order to be 115 activated. 116 + 117 + The transceiver type can be changed using 'ethtool'. 118 119 120 (4a) Interpretation of error messages and common problems