Something went wrong. Try again.
A KDE Plasma panel widget showing how much Claude Max quota is left, at a glance.
Something went wrong. Try again.
fix: the refresh button could not find dipstick
plasmashell runs with a PATH of /usr/lib64/ccache:/usr/local/bin:/usr/bin:/bin and nothing else. A `make install` into the home puts the binary in ~/.local/bin, which is not on that list, so `dipstick refresh` from the QML exited 127 and the button reported the binary as missing - while the very same command worked from a terminal, where the user's shell does have the directory on its path. The command already goes through a shell, so the path fix travels with it. A system install lands in /usr/bin and was never affected, which is exactly why the bug survived: it only shows up in the installation the developer uses.
Author Claudio Date (Sep 2, 2026, 8:43 AM UTC) Commit
Copy SHA
Parent 4cb5a1fa 4cb5a1fa0a1f65fc57a7e5390548bccb4679711d