mmc: meson-gx: enable the bus pipeline clock on T7
On the T7 SoC, the bus path between the SD/eMMC controllers and the NIC_MATRIX fabric goes through a pipeline stage inserted by the hardware design to help timing closure. The stage has its own gate clock and, when that clock is disabled, a controller that starts a DMA transfer can never complete it, hanging the storage devices and, from there, the whole system. Add a dedicated match data for the amlogic,t7-mmc compatible that makes the driver claim and enable the "pipeline" clock for as long as the device is bound. The clock is deliberately not optional: the hardware cannot do DMA without it, and failing the probe with a clear error is preferable to booting and hitting an undiagnosable DMA hang later. Assisted-by: Claude:claude-fable-5 Signed-off-by: Lucas Tanure <tanure@linux.com> Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org> Signed-off-by: Ulf Hansson <ulfh@kernel.org>