Linux kernel mirror (for testing)
git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
kernel
os
linux
1# SPDX-License-Identifier: GPL-2.0-only
2config INTEL_POWERCLAMP
3 tristate "Intel PowerClamp idle injection driver"
4 depends on X86
5 depends on CPU_SUP_INTEL
6 depends on CPU_IDLE
7 select POWERCAP
8 select IDLE_INJECT
9 help
10 Enable this to enable Intel PowerClamp idle injection driver. This
11 enforce idle time which results in more package C-state residency. The
12 user interface is exposed via generic thermal framework.
13
14config X86_THERMAL_VECTOR
15 def_bool y
16 depends on X86 && CPU_SUP_INTEL && X86_LOCAL_APIC
17
18config INTEL_TCC
19 bool
20 depends on X86
21
22config X86_PKG_TEMP_THERMAL
23 tristate "X86 package temperature thermal driver"
24 depends on X86_THERMAL_VECTOR
25 select THERMAL_GOV_USER_SPACE
26 select THERMAL_WRITABLE_TRIPS
27 select INTEL_TCC
28 default m
29 help
30 Enable this to register CPU digital sensor for package temperature as
31 thermal zone. Each package will have its own thermal zone. There are
32 two trip points which can be set by user to get notifications via thermal
33 notification methods.
34
35config INTEL_SOC_DTS_IOSF_CORE
36 tristate
37 depends on X86 && PCI
38 select IOSF_MBI
39 select INTEL_TCC
40 help
41 This is becoming a common feature for Intel SoCs to expose the additional
42 digital temperature sensors (DTSs) using side band interface (IOSF). This
43 implements the common set of helper functions to register, get temperature
44 and get/set thresholds on DTSs.
45
46config INTEL_SOC_DTS_THERMAL
47 tristate "Intel SoCs DTS thermal driver"
48 depends on X86 && PCI && ACPI
49 select INTEL_SOC_DTS_IOSF_CORE
50 select THERMAL_WRITABLE_TRIPS
51 help
52 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
53 temperature sensor (DTS). These SoCs have two additional DTSs in
54 addition to DTSs on CPU cores. Each DTS will be registered as a
55 thermal zone. There are two trip points. One of the trip point can
56 be set by user mode programs to get notifications via Linux thermal
57 notification methods.The other trip is a critical trip point, which
58 was set by the driver based on the TJ MAX temperature.
59
60config INTEL_QUARK_DTS_THERMAL
61 tristate "Intel Quark DTS thermal driver"
62 depends on X86_INTEL_QUARK
63 help
64 Enable this to register Intel Quark SoC (e.g. X1000) platform digital
65 temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
66 The DTS will be registered as a thermal zone. There are two trip points:
67 hot & critical. The critical trip point default value is set by
68 underlying BIOS/Firmware.
69
70menu "ACPI INT340X thermal drivers"
71source "drivers/thermal/intel/int340x_thermal/Kconfig"
72endmenu
73
74config INTEL_BXT_PMIC_THERMAL
75 tristate "Intel Broxton PMIC thermal driver"
76 depends on X86 && INTEL_SOC_PMIC_BXTWC
77 select REGMAP
78 help
79 Select this driver for Intel Broxton PMIC with ADC channels monitoring
80 system temperature measurements and alerts.
81 This driver is used for monitoring the ADC channels of PMIC and handles
82 the alert trip point interrupts and notifies the thermal framework with
83 the trip point and temperature details of the zone.
84
85config INTEL_PCH_THERMAL
86 tristate "Intel PCH Thermal Reporting Driver"
87 depends on X86 && PCI
88 select THERMAL_ACPI if ACPI
89 help
90 Enable this to support thermal reporting on certain intel PCHs.
91 Thermal reporting device will provide temperature reading,
92 programmable trip points and other information.
93
94config INTEL_TCC_COOLING
95 tristate "Intel TCC offset cooling Driver"
96 depends on X86
97 select INTEL_TCC
98 help
99 Enable this to support system cooling by adjusting the effective TCC
100 activation temperature via the TCC Offset register, which is widely
101 supported on modern Intel platforms.
102 Note that, on different platforms, the behavior might be different
103 on how fast the setting takes effect, and how much the CPU frequency
104 is reduced.
105
106config INTEL_HFI_THERMAL
107 bool "Intel Hardware Feedback Interface"
108 depends on NET
109 depends on CPU_SUP_INTEL
110 depends on X86_THERMAL_VECTOR
111 select THERMAL_NETLINK
112 help
113 Select this option to enable the Hardware Feedback Interface. If
114 selected, hardware provides guidance to the operating system on
115 the performance and energy efficiency capabilities of each CPU.
116 These capabilities may change as a result of changes in the operating
117 conditions of the system such power and thermal limits. If selected,
118 the kernel relays updates in CPUs' capabilities to userspace.