Linux kernel mirror (for testing)
git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
kernel
os
linux
1Common bindings for video receiver and transmitter interfaces
2
3General concept
4---------------
5
6Video data pipelines usually consist of external devices, e.g. camera sensors,
7controlled over an I2C, SPI or UART bus, and SoC internal IP blocks, including
8video DMA engines and video data processors.
9
10SoC internal blocks are described by DT nodes, placed similarly to other SoC
11blocks. External devices are represented as child nodes of their respective
12bus controller nodes, e.g. I2C.
13
14Data interfaces on all video devices are described by their child 'port' nodes.
15Configuration of a port depends on other devices participating in the data
16transfer and is described by 'endpoint' subnodes.
17
18device {
19 ...
20 ports {
21 #address-cells = <1>;
22 #size-cells = <0>;
23
24 port@0 {
25 ...
26 endpoint@0 { ... };
27 endpoint@1 { ... };
28 };
29 port@1 { ... };
30 };
31};
32
33If a port can be configured to work with more than one remote device on the same
34bus, an 'endpoint' child node must be provided for each of them. If more than
35one port is present in a device node or there is more than one endpoint at a
36port, or port node needs to be associated with a selected hardware interface,
37a common scheme using '#address-cells', '#size-cells' and 'reg' properties is
38used.
39
40All 'port' nodes can be grouped under optional 'ports' node, which allows to
41specify #address-cells, #size-cells properties independently for the 'port'
42and 'endpoint' nodes and any child device nodes a device might have.
43
44Two 'endpoint' nodes are linked with each other through their 'remote-endpoint'
45phandles. An endpoint subnode of a device contains all properties needed for
46configuration of this device for data exchange with other device. In most
47cases properties at the peer 'endpoint' nodes will be identical, however they
48might need to be different when there is any signal modifications on the bus
49between two devices, e.g. there are logic signal inverters on the lines.
50
51It is allowed for multiple endpoints at a port to be active simultaneously,
52where supported by a device. For example, in case where a data interface of
53a device is partitioned into multiple data busses, e.g. 16-bit input port
54divided into two separate ITU-R BT.656 8-bit busses. In such case bus-width
55and data-shift properties can be used to assign physical data lines to each
56endpoint node (logical bus).
57
58Documenting bindings for devices
59--------------------------------
60
61All required and optional bindings the device supports shall be explicitly
62documented in device DT binding documentation. This also includes port and
63endpoint nodes for the device, including unit-addresses and reg properties where
64relevant.
65
66Please also see Documentation/devicetree/bindings/graph.txt .
67
68Required properties
69-------------------
70
71If there is more than one 'port' or more than one 'endpoint' node or 'reg'
72property is present in port and/or endpoint nodes the following properties
73are required in a relevant parent node:
74
75 - #address-cells : number of cells required to define port/endpoint
76 identifier, should be 1.
77 - #size-cells : should be zero.
78
79
80Optional properties
81-------------------
82
83- flash-leds: An array of phandles, each referring to a flash LED, a sub-node
84 of the LED driver device node.
85
86- lens-focus: A phandle to the node of the focus lens controller.
87
88- rotation: The device, typically an image sensor, is not mounted upright,
89 but a number of degrees counter clockwise. Typical values are 0 and 180
90 (upside down).
91
92
93Optional endpoint properties
94----------------------------
95
96- remote-endpoint: phandle to an 'endpoint' subnode of a remote device node.
97- slave-mode: a boolean property indicating that the link is run in slave mode.
98 The default when this property is not specified is master mode. In the slave
99 mode horizontal and vertical synchronization signals are provided to the
100 slave device (data source) by the master device (data sink). In the master
101 mode the data source device is also the source of the synchronization signals.
102- bus-type: data bus type. Possible values are:
103 1 - MIPI CSI-2 C-PHY
104 2 - MIPI CSI1
105 3 - CCP2
106 4 - MIPI CSI-2 D-PHY
107 5 - Parallel
108 6 - Bt.656
109- bus-width: number of data lines actively used, valid for the parallel busses.
110- data-shift: on the parallel data busses, if bus-width is used to specify the
111 number of data lines, data-shift can be used to specify which data lines are
112 used, e.g. "bus-width=<8>; data-shift=<2>;" means, that lines 9:2 are used.
113- hsync-active: active state of the HSYNC signal, 0/1 for LOW/HIGH respectively.
114- vsync-active: active state of the VSYNC signal, 0/1 for LOW/HIGH respectively.
115 Note, that if HSYNC and VSYNC polarities are not specified, embedded
116 synchronization may be required, where supported.
117- data-active: similar to HSYNC and VSYNC, specifies data line polarity.
118- data-enable-active: similar to HSYNC and VSYNC, specifies the data enable
119 signal polarity.
120- field-even-active: field signal level during the even field data transmission.
121- pclk-sample: sample data on rising (1) or falling (0) edge of the pixel clock
122 signal.
123- sync-on-green-active: active state of Sync-on-green (SoG) signal, 0/1 for
124 LOW/HIGH respectively.
125- data-lanes: an array of physical data lane indexes. Position of an entry
126 determines the logical lane number, while the value of an entry indicates
127 physical lane, e.g. for 2-lane MIPI CSI-2 bus we could have
128 "data-lanes = <1 2>;", assuming the clock lane is on hardware lane 0.
129 If the hardware does not support lane reordering, monotonically
130 incremented values shall be used from 0 or 1 onwards, depending on
131 whether or not there is also a clock lane. This property is valid for
132 serial busses only (e.g. MIPI CSI-2).
133- clock-lanes: an array of physical clock lane indexes. Position of an entry
134 determines the logical lane number, while the value of an entry indicates
135 physical lane, e.g. for a MIPI CSI-2 bus we could have "clock-lanes = <0>;",
136 which places the clock lane on hardware lane 0. This property is valid for
137 serial busses only (e.g. MIPI CSI-2). Note that for the MIPI CSI-2 bus this
138 array contains only one entry.
139- clock-noncontinuous: a boolean property to allow MIPI CSI-2 non-continuous
140 clock mode.
141- link-frequencies: Allowed data bus frequencies. For MIPI CSI-2, for
142 instance, this is the actual frequency of the bus, not bits per clock per
143 lane value. An array of 64-bit unsigned integers.
144- lane-polarities: an array of polarities of the lanes starting from the clock
145 lane and followed by the data lanes in the same order as in data-lanes.
146 Valid values are 0 (normal) and 1 (inverted). The length of the array
147 should be the combined length of data-lanes and clock-lanes properties.
148 If the lane-polarities property is omitted, the value must be interpreted
149 as 0 (normal). This property is valid for serial busses only.
150- strobe: Whether the clock signal is used as clock (0) or strobe (1). Used
151 with CCP2, for instance.
152
153Example
154-------
155
156The example snippet below describes two data pipelines. ov772x and imx074 are
157camera sensors with a parallel and serial (MIPI CSI-2) video bus respectively.
158Both sensors are on the I2C control bus corresponding to the i2c0 controller
159node. ov772x sensor is linked directly to the ceu0 video host interface.
160imx074 is linked to ceu0 through the MIPI CSI-2 receiver (csi2). ceu0 has a
161(single) DMA engine writing captured data to memory. ceu0 node has a single
162'port' node which may indicate that at any time only one of the following data
163pipelines can be active: ov772x -> ceu0 or imx074 -> csi2 -> ceu0.
164
165 ceu0: ceu@fe910000 {
166 compatible = "renesas,sh-mobile-ceu";
167 reg = <0xfe910000 0xa0>;
168 interrupts = <0x880>;
169
170 mclk: master_clock {
171 compatible = "renesas,ceu-clock";
172 #clock-cells = <1>;
173 clock-frequency = <50000000>; /* Max clock frequency */
174 clock-output-names = "mclk";
175 };
176
177 port {
178 #address-cells = <1>;
179 #size-cells = <0>;
180
181 /* Parallel bus endpoint */
182 ceu0_1: endpoint@1 {
183 reg = <1>; /* Local endpoint # */
184 remote = <&ov772x_1_1>; /* Remote phandle */
185 bus-width = <8>; /* Used data lines */
186 data-shift = <2>; /* Lines 9:2 are used */
187
188 /* If hsync-active/vsync-active are missing,
189 embedded BT.656 sync is used */
190 hsync-active = <0>; /* Active low */
191 vsync-active = <0>; /* Active low */
192 data-active = <1>; /* Active high */
193 pclk-sample = <1>; /* Rising */
194 };
195
196 /* MIPI CSI-2 bus endpoint */
197 ceu0_0: endpoint@0 {
198 reg = <0>;
199 remote = <&csi2_2>;
200 };
201 };
202 };
203
204 i2c0: i2c@fff20000 {
205 ...
206 ov772x_1: camera@21 {
207 compatible = "ovti,ov772x";
208 reg = <0x21>;
209 vddio-supply = <®ulator1>;
210 vddcore-supply = <®ulator2>;
211
212 clock-frequency = <20000000>;
213 clocks = <&mclk 0>;
214 clock-names = "xclk";
215
216 port {
217 /* With 1 endpoint per port no need for addresses. */
218 ov772x_1_1: endpoint {
219 bus-width = <8>;
220 remote-endpoint = <&ceu0_1>;
221 hsync-active = <1>;
222 vsync-active = <0>; /* Who came up with an
223 inverter here ?... */
224 data-active = <1>;
225 pclk-sample = <1>;
226 };
227 };
228 };
229
230 imx074: camera@1a {
231 compatible = "sony,imx074";
232 reg = <0x1a>;
233 vddio-supply = <®ulator1>;
234 vddcore-supply = <®ulator2>;
235
236 clock-frequency = <30000000>; /* Shared clock with ov772x_1 */
237 clocks = <&mclk 0>;
238 clock-names = "sysclk"; /* Assuming this is the
239 name in the datasheet */
240 port {
241 imx074_1: endpoint {
242 clock-lanes = <0>;
243 data-lanes = <1 2>;
244 remote-endpoint = <&csi2_1>;
245 };
246 };
247 };
248 };
249
250 csi2: csi2@ffc90000 {
251 compatible = "renesas,sh-mobile-csi2";
252 reg = <0xffc90000 0x1000>;
253 interrupts = <0x17a0>;
254 #address-cells = <1>;
255 #size-cells = <0>;
256
257 port@1 {
258 compatible = "renesas,csi2c"; /* One of CSI2I and CSI2C. */
259 reg = <1>; /* CSI-2 PHY #1 of 2: PHY_S,
260 PHY_M has port address 0,
261 is unused. */
262 csi2_1: endpoint {
263 clock-lanes = <0>;
264 data-lanes = <2 1>;
265 remote-endpoint = <&imx074_1>;
266 };
267 };
268 port@2 {
269 reg = <2>; /* port 2: link to the CEU */
270