Linux kernel mirror (for testing) git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
kernel os linux
1
fork

Configure Feed

Select the types of activity you want to include in your feed.

at v4.20 132 lines 5.5 kB view raw
1Adaptive Body Bias(ABB) SoC internal LDO regulator for Texas Instruments SoCs 2 3Required Properties: 4- compatible: Should be one of: 5 - "ti,abb-v1" for older SoCs like OMAP3 6 - "ti,abb-v2" for newer SoCs like OMAP4, OMAP5 7 - "ti,abb-v3" for a generic definition where setup and control registers are 8 provided (example: DRA7) 9- reg: Address and length of the register set for the device. It contains 10 the information of registers in the same order as described by reg-names 11- reg-names: Should contain the reg names 12 - "base-address" - contains base address of ABB module (ti,abb-v1,ti,abb-v2) 13 - "control-address" - contains control register address of ABB module (ti,abb-v3) 14 - "setup-address" - contains setup register address of ABB module (ti,abb-v3) 15 - "int-address" - contains address of interrupt register for ABB module 16 (also see Optional properties) 17- #address-cells: should be 0 18- #size-cells: should be 0 19- clocks: should point to the clock node used by ABB module 20- ti,settling-time: Settling time in uSecs from SoC documentation for ABB module 21 to settle down(target time for SR2_WTCNT_VALUE). 22- ti,clock-cycles: SoC specific data about count of system ti,clock-cycles used for 23 computing settling time from SoC Documentation for ABB module(clock 24 cycles for SR2_WTCNT_VALUE). 25- ti,tranxdone-status-mask: Mask to the int-register to write-to-clear mask 26 indicating LDO tranxdone (operation complete). 27- ti,abb_info: An array of 6-tuples u32 items providing information about ABB 28 configuration needed per operational voltage of the device. 29 Each item consists of the following in the same order: 30 volt: voltage in uV - Only used to index ABB information. 31 ABB mode: one of the following: 32 0-bypass 33 1-Forward Body Bias(FBB) 34 3-Reverse Body Bias(RBB) 35 efuse: (see Optional properties) 36 RBB enable efuse Mask: (See Optional properties) 37 FBB enable efuse Mask: (See Optional properties) 38 Vset value efuse Mask: (See Optional properties) 39 40 NOTE: If more than 1 entry is present, then regulator is setup to change 41 voltage, allowing for various modes to be selected indexed off 42 the regulator. Further, ABB LDOs are considered always-on by 43 default. 44 45Optional Properties: 46- reg-names: In addition to the required properties, the following are optional 47 - "efuse-address" - Contains efuse base address used to pick up ABB info. 48 - "ldo-address" - Contains address of ABB LDO override register. 49 "efuse-address" is required for this. 50- ti,ldovbb-vset-mask - Required if ldo-address is set, mask for LDO override 51 register to provide override vset value. 52- ti,ldovbb-override-mask - Required if ldo-address is set, mask for LDO 53 override register to enable override vset value. 54- ti,abb_opp_sel: Addendum to the description in required properties 55 efuse: Mandatory if 'efuse-address' register is defined. Provides offset 56 from efuse-address to pick up ABB characteristics. Set to 0 if 57 'efuse-address' is not defined. 58 RBB enable efuse Mask: Optional if 'efuse-address' register is defined. 59 'ABB mode' is force set to RBB mode if value at "efuse-address" 60 + efuse maps to RBB mask. Set to 0 to ignore this. 61 FBB enable efuse Mask: Optional if 'efuse-address' register is defined. 62 'ABB mode' is force set to FBB mode if value at "efuse-address" 63 + efuse maps to FBB mask (valid only if RBB mask does not match) 64 Set to 0 to ignore this. 65 Vset value efuse Mask: Mandatory if ldo-address is set. Picks up from 66 efuse the value to set in 'ti,ldovbb-vset-mask' at ldo-address. 67 68Example #1: Simplest configuration (no efuse data, hard coded ABB table): 69abb_x: regulator-abb-x { 70 compatible = "ti,abb-v1"; 71 regulator-name = "abb_x"; 72 #address-cells = <0>; 73 #size-cells = <0>; 74 reg = <0x483072f0 0x8>, <0x48306818 0x4>; 75 reg-names = "base-address", "int-address"; 76 ti,tranxdone-status-mask = <0x4000000>; 77 clocks = <&sysclk>; 78 ti,settling-time = <30>; 79 ti,clock-cycles = <8>; 80 ti,abb_info = < 81 /* uV ABB efuse rbb_m fbb_m vset_m */ 82 1012500 0 0 0 0 0 /* Bypass */ 83 1200000 3 0 0 0 0 /* RBB mandatory */ 84 1320000 1 0 0 0 0 /* FBB mandatory */ 85 >; 86}; 87 88Example #2: Efuse bits contain ABB mode setting (no LDO override capability) 89abb_y: regulator-abb-y { 90 compatible = "ti,abb-v2"; 91 regulator-name = "abb_y"; 92 #address-cells = <0>; 93 #size-cells = <0>; 94 reg = <0x4a307bd0 0x8>, <0x4a306014 0x4>, <0x4A002268 0x8>; 95 reg-names = "base-address", "int-address", "efuse-address"; 96 ti,tranxdone-status-mask = <0x4000000>; 97 clocks = <&sysclk>; 98 ti,settling-time = <50>; 99 ti,clock-cycles = <16>; 100 ti,abb_info = < 101 /* uV ABB efuse rbb_m fbb_m vset_m */ 102 975000 0 0 0 0 0 /* Bypass */ 103 1012500 0 0 0x40000 0 0 /* RBB optional */ 104 1200000 0 0x4 0 0x40000 0 /* FBB optional */ 105 1320000 1 0 0 0 0 /* FBB mandatory */ 106 >; 107}; 108 109Example #3: Efuse bits contain ABB mode setting and LDO override capability 110abb_z: regulator-abb-z { 111 compatible = "ti,abb-v2"; 112 regulator-name = "abb_z"; 113 #address-cells = <0>; 114 #size-cells = <0>; 115 reg = <0x4ae07ce4 0x8>, <0x4ae06010 0x4>, 116 <0x4a002194 0x8>, <0x4ae0C314 0x4>; 117 reg-names = "base-address", "int-address", 118 "efuse-address", "ldo-address"; 119 ti,tranxdone-status-mask = <0x8000000>; 120 /* LDOVBBMM_MUX_CTRL */ 121 ti,ldovbb-override-mask = <0x400>; 122 /* LDOVBBMM_VSET_OUT */ 123 ti,ldovbb-vset-mask = <0x1F>; 124 clocks = <&sysclk>; 125 ti,settling-time = <50>; 126 ti,clock-cycles = <16>; 127 ti,abb_info = < 128 /* uV ABB efuse rbb_m fbb_m vset_m */ 129 975000 0 0 0 0 0 /* Bypass */ 130 1200000 0 0x4 0 0x40000 0x1f00 /* FBB optional, vset */ 131 >; 132};