A Prometheus exporter for the goCoax MA2500D
gocoax-exporter docs data-inventory.md
5.4 kB · 111 lines
Markdown
at main

Device data inventory #

This document maps every management endpoint the exporter scrapes to the Prometheus metric that exposes the data it returns. Its purpose is to make the coverage claim explicit and auditable: for each device read below, the decoded value is either surfaced as a metric or listed in Not exported with the reason.

The device speaks HTTP on port 80 with HTTP Basic Auth plus a rotating csrf_token cookie echoed back as X-CSRF-TOKEN on every POST. The exporter only issues read requests; see the top-level README.md for the request shape.

Scrape sequence #

The collector drives this sequence once per scrape, per device. All reads inherit the scrape's context, so cancelling the scrape aborts in-flight device calls.

# Endpoint Request body Decodes Exposed as
1 GET /phyRates.html — — (establishes the CSRF cookie) —
2 POST /ms/0/0x15 {"data":[]} local info see below
3 POST /ms/0/0x16 {"data":[nodeID]} (per active node) node info see below
4 POST /ms/1/0x103/GET {"data":[myNodeID]} device MAC gocoax_device_info{mac_address}
5 POST /ms/1/0x20b/GET — device IPv4 gocoax_device_info{ip_address}
6 POST /ms/1/0x303/GET {"data":[0]} chip ID gocoax_device_info{chip}
7 POST /ms/0/0x14 {"data":[0]} Ethernet counters gocoax_ethernet_*_total
8 POST /ms/0/0x24 {"data":[]} beacon channel gocoax_beacon_channel_mhz
9 POST /ms/0/0x7f {"data":[]} bonded channel info gocoax_first_channel_mhz, gocoax_channel_count
10 POST /ms/0/0x1D {"data":[1<<nodeID,version]} (per active node) raw PHY/FMR payload gocoax_phy_rate_*_mbps

Local info (/ms/0/0x15) #

data is an array of 32-bit words. The fields the collector decodes:

Word index Meaning Exposed as
[0] my node ID gocoax_device_info{node_id}
[1] (low byte) network-coordinator node ID gocoax_node_info{is_nc}, gocoax_device_info{is_nc}
[5] link status gocoax_link_up
[11] network MoCA version code gocoax_moca_network_info{version}
[12] active-node bitmask internal (drives per-node reads; active-node count is count(gocoax_node_info))
[18], [19], [28] primary/secondary LOF offsets, custom band profile internal (derive gocoax_primary_channel_mhz / gocoax_secondary_channel_mhz)
[21]… SOC/firmware version string gocoax_device_info{soc_version}

Node info (/ms/0/0x16) #

Returned per active node:

Word index Meaning Exposed as
request nodeID node ID gocoax_node_info{node}
[0], [1] node MAC address gocoax_node_info{mac_address}
[4] (low byte) node MoCA version code gocoax_node_info{moca_version}
local-info [1] whether this node is the NC gocoax_node_info{is_nc}

Frame info (/ms/0/0x14) #

The device reports six Ethernet counters as 64-bit values split across two 32-bit words each (high word at index N, low at N+1):

Words Exposed as
[12] [13] gocoax_ethernet_tx_good_total
[30] [31] gocoax_ethernet_tx_bad_total
[48] [49] gocoax_ethernet_tx_dropped_total
[66] [67] gocoax_ethernet_rx_good_total
[84] [85] gocoax_ethernet_rx_bad_total
[102] [103] gocoax_ethernet_rx_dropped_total

PHY rates (/ms/0/0x1D) #

The FMR payload is not meaningful on its own; the exporter decodes it into directional NPER/VLPER rates and the broadcast/multicast (GCD) rate:

  • gocoax_phy_rate_nper_mbps{from_node,to_node}
  • gocoax_phy_rate_vlper_mbps{from_node,to_node}
  • gocoax_phy_rate_gcd_mbps{node}

Not exported #

These device values are read or available but deliberately not turned into a standalone metric:

  • Raw management words beyond the decoded fields above (for example the remaining data words in local info, node info, and frame info). Their meaning is not established, so exporting them would be guessing; the decoded subset above is what the device's own status pages label.
  • Primary/secondary LOF offsets and custom band profile. They are intermediate values used to derive gocoax_primary_channel_mhz and gocoax_secondary_channel_mhz; the derived frequencies are what users care about.
  • Active-node bitmask. It drives which nodes are read; the node count is available as count(gocoax_node_info).
  • LOF frequency (/ms/0/0x1003/GET). This equals the beacon channel already exposed as gocoax_beacon_channel_mhz. The capture script records it in testdata for completeness, but the collector does not issue a separate request because the value is already obtained from misc-phy.
  • MoCA preshared keys (/security.html). Never fetched or captured: they are on-the-wire secrets and must not leave the device.

Testdata relationship #

The committed captures under testdata/<name>/ replay the endpoints above (plus the LOF read noted above). Tests seed their mocks directly from those captures, so the metric-output assertions are exercising real device responses rather than hand-written fixtures. Re-capture with:

python3 scripts/capture.py --config .private/gocoax-exporter.cfg --out testdata