Upgrading from 3.3 to 4.0 #
4.0 is a hard break with no compatibility layer. Almost nothing was deleted: of the 885 names the root exported in 3.3.0, seventy-eight exist nowhere any more and the rest simply live at a named address instead of a flat one. So most of the work is an import sweep, and this page is mostly a map.
Read the first two sections and you can fix the imports. Read the third even if you are in a hurry, because in four places, one of them only for code written against 4.0.0rc1, the obvious fix is the wrong one, and three of those four change a number without raising anything.
The one rule: imports move down one level #
In 3.3.0 the root re-exported the whole library, so from phonometry import laeq worked for almost every name. Today the root exports twenty-five things:
the twenty-one subpackages, the three classes that belong to no single domain
(Signal, ReportMetadata, PhonometryWarning) and __version__.
import phonometry
print(len(phonometry.__all__)) # 25
print("laeq" in phonometry.__all__) # False
from phonometry.signals import laeq # this is the new spelling
Measured across the whole surface, 804 of those 885 root names are published
today by exactly one subpackage, none by two, and none needs a path deeper
than phonometry.<subpackage>. Three more are still at the root, where they
always were. So the swap is unambiguous: find the subpackage, import from it.
The attribute form was never removed, which is the smallest possible diff for code that reached through the root:
from phonometry import filters
print(filters.nominal_frequencies(1).labels)
Finding the new home of a name #
Rather than search the reference for each one, ask the installed package:
import importlib
import pkgutil
import phonometry
def whereis(name):
"""Every public module that publishes `name`, shallowest first."""
found = ["phonometry"] if name in phonometry.__all__ else []
for attribute in phonometry.__all__:
package = getattr(phonometry, attribute)
if not hasattr(package, "__path__"):
continue
modules = [package.__name__]
modules += [m.name for m in pkgutil.walk_packages(package.__path__, package.__name__ + ".")]
for module_name in modules:
if any(part.startswith("_") for part in module_name.split(".")):
continue
try:
module = importlib.import_module(module_name)
except ImportError:
continue
if name in getattr(module, "__all__", ()):
found.append(module_name)
return sorted(found, key=lambda path: path.count("."))
print(whereis("laeq")[0]) # phonometry.signals
print(whereis("reverberation_time")[0]) # phonometry.room
print(whereis("sensitivity")[0]) # phonometry.metrology
print(whereis("Signal")[0]) # phonometry
It walks the tree in about two seconds. When it returns several paths the
shallowest one is the canonical import: a subpackage re-exports what its own
modules publish, and that shallow path is the one the guides and the tests
use. The four names the root still publishes on its own, Signal,
PhonometryWarning, ReportMetadata and __version__, come back as
phonometry itself. An empty list means the name is in the last section of
this page.
Modules that split rather than moved #
Five of the thirty modules that changed path did not move to one new address.
They were divided, and a reader who follows only the first half of the split
gets an ImportError for the rest. These are worth checking one by one, and
the private renderer package is listed with them because the same thing
happened to it:
| 3.3.0 module | Where its contents are now |
|---|---|
phonometry.impedance_tube |
materials.absorbers.impedance_tube (two-microphone transfer function), materials.absorbers.four_microphone (TransferMatrix, transfer_matrix_one_load, wave_decomposition, face_quantities, air_layer_transfer_matrix), materials.absorbers.standing_wave, and fluids |
phonometry.scattering_diffusion |
materials.diffusers.reverberation_room_scattering for the reverberation-room part (ScatteringResult, ScatteringUncertainty, BASE_PLATE_BANDS_HZ and the rest), materials.diffusers.scattering_diffusion for the nine free-field names |
phonometry.materials.porous_absorber |
materials.absorbers.porous for the bulk-material models, materials.absorbers.layered for the whole multilayer API (layered_absorber, AirLayer, MembraneLayer, PerforatedPlateLayer, MicroperforatedPlateLayer, LayeredAbsorberResult) |
phonometry.metrology.spectra |
signals.spectra, plus signals.multitaper (multitaper_psd) and signals.windows (window_metrics) |
phonometry.compliance |
filters.compliance (FilterComplianceResult, class_limits, verify_filter_class), filters.weighting_compliance (verify_weighting_class, weighting_class_limits), aircraft.measurement_system (verify_aircraft_noise_system) |
phonometry._plotting |
phonometry._plot.<domain>: the 82 renderers were split per domain, so plot_airborne_insulation is in _plot.building and plot_age_threshold in _plot.hearing. Private either way, and .plot() on the result is the supported route |
The other twenty-five moved whole, and the resolver above finds them without reading this table. Each of the first three was reachable by two paths in 3.3.0, the flat one and the one under its package, and both are gone.
Four where the obvious fix is the wrong one #
Everything else on this page announces itself the moment you run it, and the fix is the one it looks like. These four are not that.
The impedance-tube helpers took kelvin #
air_density_iso and speed_of_sound_iso documented and consumed their
temperature in kelvin. Their successors take degrees Celsius, like the
rest of the library. The names changed, so the import fails and you will
notice, but the argument you carry over is the problem: 293.15 is a
legitimate-looking number in either unit.
from phonometry.materials import speed_of_sound_iso10534
print(round(float(speed_of_sound_iso10534(temperature_c=20.0)), 5)) # 343.28784
print(round(float(speed_of_sound_iso10534(temperature_c=293.15)), 5)) # 477.13003
343.29 m/s against 477.13 m/s: a 39 % error, no exception, and every absorption coefficient computed from it is wrong by a plausible-looking amount. Convert the value, do not just rename the keyword.
| 3.3.0 | 4.0 |
|---|---|
impedance_tube.air_density_iso(T_kelvin, p_kPa) |
materials.air_density_iso10534(temperature_c=T_kelvin - 273.15, static_pressure_kpa=p_kPa) |
impedance_tube.speed_of_sound_iso(T_kelvin) |
materials.speed_of_sound_iso10534(temperature_c=T_kelvin - 273.15) |
With the conversion applied both return exactly what they returned in 3.3.0, bit for bit.
GasStream took kelvin #
noise_control.GasStream held the inlet temperature of IEC 60534-8-3 as
inlet_temperature_k in 4.0.0rc1, in kelvin, the way Clause 5 reads it.
In 4.0 the field is inlet_temperature_c, in degrees Celsius like every other
temperature the library takes, and the conversion to the absolute temperature
Clause 5 needs happens inside. The keyword fails, so you will notice, but
450.0 is as legitimate a number in one unit as in the other: rename the
keyword and keep the number, and the gas is 273.15 K hotter. Annex A's
example 1 at 450 K puts 91.7 dB(A) at 1 m from the pipe; the same 450 read as
degrees Celsius puts 93.0 dB(A) there, and nothing raises.
| 4.0.0rc1 | 4.0 |
|---|---|
GasStream(inlet_temperature_k=T_kelvin, ...) |
GasStream(inlet_temperature_c=T_kelvin - 273.15, ...) |
speed_of_sound is speed_of_sound_iso17497, not fluids.air() #
The speed_of_sound(temperature) of 3.3.0, at the top level and in
materials.scattering_diffusion, is the ISO 17497-1 one-liner, and in 4.0 it
is materials.speed_of_sound_iso17497: the same formula and the same number,
with the temperature, still in degrees Celsius, written by name. The trap is
the other candidate. fluids.air() is where the rest of 4.0 reads the speed of
sound of the air from, so it looks like the new home of a function that
returned one, but it computes humid air by IEC 61094-2 Annex F: at 20 °C it
answers 343.99 m/s where the ISO 17497-1 formula answers 343.20 m/s, and
nothing raises. That is small, and it is not nothing if you are reproducing a
measurement made with the old number.
from phonometry import fluids, materials
print(round(float(materials.speed_of_sound_iso17497(temperature_c=20.0)), 2)) # 343.2
air = fluids.air(temperature_c=20.0, relative_humidity_percent=50.0, static_pressure_pa=101_325.0)
print(round(air.speed_of_sound, 2)) # 343.99
| 3.3.0 | 4.0 |
|---|---|
speed_of_sound(T_celsius) |
materials.speed_of_sound_iso17497(temperature_c=T_celsius) |
The tl field of an underwater result is pl #
transmission_loss became propagation_loss, which the import catches, and
the field inside the result was renamed with it. That one does not raise: a
PropagationLossResult has no .tl, so the AttributeError arrives wherever
you read it, which may be far from the call.
from phonometry.underwater.propagation.closed_form import propagation_loss
result = propagation_loss([1000.0], 1000.0)
print(round(float(result.pl[0]), 5)) # 60.06013, the number .tl used to hold
The same rename reaches underwater.sonar_equation, whose
transmission_loss parameter is now propagation_loss.
The environment moved into a dataclass #
Five entry points no longer take the ambient conditions as loose numbers. Renaming the keyword is not enough there, because the parameter is gone entirely:
| 3.3.0 | 4.0 |
|---|---|
airport_noise.event_level(..., temperature=15.0, pressure=101.325) |
event_level(..., atmosphere=AerodromeAtmosphere(temperature_c=15.0, static_pressure_kpa=101.325)) |
airport_noise.noise_contour(...) |
the same, with AerodromeAtmosphere |
rotorcraft_noise.rotorcraft_event_level(..., temperature=15.0, relative_humidity=70.0) |
rotorcraft_event_level(..., atmosphere=RotorcraftAtmosphere(temperature_c=15.0, relative_humidity_percent=70.0)) |
rotorcraft_noise.rotorcraft_noise_contour(...) |
the same, with RotorcraftAtmosphere |
outdoor_propagation.predicted_receiver_level(..., humidity=70.0) |
predicted_receiver_level(..., atmosphere=AtmosphericConditions(relative_humidity_percent=70.0)) |
The other options of these functions went into records too, the per-point rotorcraft overrides among them, and the next section maps them.
from phonometry.aircraft.airport_noise import AerodromeAtmosphere
atmosphere = AerodromeAtmosphere(temperature_c=15.0, static_pressure_kpa=101.325)
print(atmosphere.temperature_c, atmosphere.static_pressure_kpa)
The longest signatures take their options in records #
Ten signatures took more than thirteen parameters each, and in 4.0 the
options that belong together are one record. A 3.3.0 keyword among them is
not renamed but gone, so a call that passes one raises TypeError: build the
record the keyword went into and pass that. Every field
of a record is written by name, and a field with a default has the default its
keyword had, so a record carries only what you change. The atmospheres of the
section above are records of the same kind; these are the rest:
| 3.3.0 | 4.0 |
|---|---|
filter_type=, ripple= and attenuation= on octave_filter and OctaveFilterBank, and resample= on OctaveFilterBank |
design=filters.FilterDesign(filter_type=..., ripple=..., attenuation=..., resample=...) |
calibration_factor= and dbfs= on octave_filter and OctaveFilterBank |
calibration=filters.LevelCalibration(factor=..., dbfs=...) |
show= and plot_file= on octave_filter and OctaveFilterBank |
response_plot=filters.ResponsePlot(show=..., file=...) |
stateful= and steady_ic= on OctaveFilterBank |
block_processing=filters.BlockProcessing(stateful=..., steady_ic=...) |
polar=, polar_frequency= and directivity_index_db= on microphone_characteristics |
directivity=electroacoustics.MicrophoneDirectivity(polar=..., frequency=..., index=...) |
noise_voltage=, equivalent_noise_level_db=, noise_weighting= and noise_spectrum= on microphone_characteristics |
noise=electroacoustics.MicrophoneNoise(voltage_v=..., equivalent_level=..., weighting=..., spectrum=...), whose weighting is "A" or "468", as the table of one spelling per concept says |
max_spl_db=, max_spl_thd_percent= and distortion= on microphone_characteristics |
overload=electroacoustics.MicrophoneOverload(spl=..., thd_percent=..., distortion=...) |
rated_impedance=, minimum_load_impedance=, powering= and supply_current_ma= on microphone_characteristics |
electrical=electroacoustics.MicrophoneElectrical(rated_impedance_ohm=..., min_load_impedance_ohm=..., powering=..., supply_current_ma=...) |
directivity= (a RadiatingPistonResult), polar=, polar_frequency= and directivity_index_db= on loudspeaker_characteristics |
directivity=electroacoustics.LoudspeakerDirectivity(piston=..., polar=..., frequency=..., index=...) |
rated_frequency_range=, rated_noise_power=, rated_sinusoidal_power= and resonance_frequency= on loudspeaker_characteristics |
ratings=electroacoustics.LoudspeakerRatings(frequency_range=..., noise_power=..., sinusoidal_power=..., resonance_frequency=...) |
absorption_area=, reverberation_time=, volume=, mean_absorption_coefficient= and room_surface= on sound_power_pressure |
room=emission.RoomEnvironment(...), with the same five names |
distance, source_height and receiver_height by position, and projected_distance=, on predicted_receiver_level |
environment.PropagationGeometry(distance=..., source_height_m=..., receiver_height_m=..., projected_distance=...) as the second argument, after the sound power level |
ground_source=, ground_middle= and ground_receiver= on predicted_receiver_level |
ground=environment.GroundFactors(source=..., middle=..., receiver=...) |
directivity_index= and d_omega= on predicted_receiver_level |
directivity=environment.DirectivityCorrection(index=..., d_omega=...) |
ground_roll=, landing_roll= and bank= on aircraft.event_level and noise_contour |
segments=aircraft.FlightSegmentState(ground_roll=..., landing_roll=..., bank=...) |
atmospheric_method= on rotorcraft_event_level and rotorcraft_noise_contour |
the atmospheric_method of their RotorcraftAtmosphere |
receiver_height=, ground_elevation=, flow_resistivity=, terrain= and terrain_resolution= on the same two |
ground=aircraft.RotorcraftGround(receiver_height_m=..., ground_elevation=..., flow_resistivity=..., terrain=..., terrain_resolution=...) |
airspeed=, path_angle=, heading= and bank_angle= on the same two |
track_state=aircraft.RotorcraftTrackState(airspeed=..., path_angle_deg=..., heading=..., bank_angle_deg=...) |
scaling_factor= and triangles= on the same two |
interpolation=aircraft.FlightConditionInterpolation(scaling_factor=..., triangles=...) |
OctaveFilterBank(48000, 3) reads as it did, because the four arguments
callers write by position kept their places; on octave_filter every option
after limits is written by name.
import numpy as np
from phonometry import filters
x = np.random.default_rng(0).standard_normal(48_000)
try:
filters.octave_filter(x, 48_000, calibration_factor=2.0)
except TypeError as error:
print(type(error).__name__)
# TypeError
result = filters.octave_filter(x, 48_000, calibration=filters.LevelCalibration(factor=2.0))
print(len(result.frequencies))
# 11
The air of a model is one fluid= #
Twenty-two functions of 3.3.0 took the air they compute in as loose numbers:
a speed of sound and a density, for the visco-thermal models a viscosity, a
Prandtl number, a ratio of specific heats and a static pressure, and for the
thermal correction of ISO 9053-2 a specific heat and a thermal conductivity,
each with a default of its own. In 4.0 these twenty-two take one fluid=, a
fluids.Fluid that carries every property its model reads, and their loose
keywords are gone, so a call that passed one raises TypeError. Other functions
that take a speed of sound or a density, expansion_chamber among them, keep
their own keywords. Left out, fluid= is
materials.ABSORBER_AIR, which holds the defaults 3.3.0 had: 343 m/s,
1.205 kg/m³, 1.84·10⁻⁵ Pa s, a Prandtl number of 0.71, a ratio of specific heats
of 1.4 and 101.325 kPa. A call that never passed the air gives the number it
gave.
| 3.3.0 | 4.0 |
|---|---|
speed_of_sound= and air_density= on delany_bazley, miki, membrane_resonance_frequency, mass_law_transmission_loss, single_panel_transmission_loss, double_wall_transmission_loss, mass_spring_mass_resonance, ground_effect and barrier_insertion_loss |
fluid= |
speed_of_sound=, air_density= and viscosity= on layered_absorber and diffuse_field_absorption; air_density= and viscosity= on perforated_plate_impedance and microperforated_plate_impedance |
fluid= |
speed_of_sound=, air_density=, viscosity=, prandtl_number=, heat_capacity_ratio= and atmospheric_pressure= on johnson_champoux_allard, slit_helmholtz_absorber and critical_coupling_design, and the same less speed_of_sound= on helmholtz_resonator_impedance, slit_effective_properties and rectangular_duct_properties |
fluid=, whose static_pressure_pa is the pressure, in pascals as before |
air_density= on atmospheric_parabolic_equation |
fluid= |
speed_of_sound=, air_density=, specific_heat_ratio=, specific_heat_cp= and thermal_conductivity= on effective_kappa, and the same less specific_heat_ratio= on thermal_boundary_layer_thickness |
fluid=, with another default, below |
Pass the air you mean as a Fluid. fluids.air() computes one at a
temperature, a humidity and a pressure, and a Fluid built by hand carries the
numbers a book prints. A model that reads a property the fluid does not carry
raises fluids.FluidPropertyUnavailableError, naming it.
import numpy as np
from phonometry import fluids, materials
f = np.array([250.0, 1000.0])
print(materials.delany_bazley(f, 20_000.0).characteristic_impedance.round(1))
# [971.5-775.5j 609.6-281.1j]
book_air = fluids.Fluid(
temperature_c=20.0,
static_pressure_pa=101_325.0,
composition={},
model="the air of the book being reproduced",
validity="",
properties={"speed_of_sound": 340.0, "density": 1.21},
)
# delany_bazley(f, 20000.0, speed_of_sound=340.0, air_density=1.21) in 3.3.0
print(materials.delany_bazley(f, 20_000.0, fluid=book_air).characteristic_impedance.round(1))
# [965.3-769.6j 606.1-279.j ]
Two of the twenty-two take another air by default. effective_kappa and
thermal_boundary_layer_thickness, the thermal correction of ISO 9053-2,
defaulted in 3.3.0 to the five values ISO 9053-2 Annex A.3 prints, two of
which are not the air the annex says it uses (errata register).
In 4.0 they default to that air, IEC 61094-2 Annex F at the Annex A.3 state of
23 °C, 101.325 kPa and 50 % relative humidity. The correction moves in its
fifth figure, effective_kappa(0.01, 0.001, 250.0) is 1.400297 where it was
1.400339, and the printed Annex A.3 results still come out.
A parameter that names a quantity carries its unit #
Everywhere else, the ambient conditions kept their place and gained a suffix. The rule is that a public parameter naming a dimensional quantity ends in the unit the caller types, because a number is where a unit is lost and no guard can catch it by magnitude: 101.325 and 101325 are both legitimate pressures in this library.
| 3.3.0 | 4.0 |
|---|---|
temperature= |
temperature_c= |
pressure= on air_attenuation, air_attenuation_m (now air_power_attenuation_per_m), atmospheric_attenuation, atmospheric_absorption, outdoor_propagation_attenuation, sae_band_attenuation (now band_attenuation_arp5534), impedance_adjustment and atmospheric_adjustment, and on the event_level and noise_contour methods of AnpAircraft and AnpDatabase; static_pressure= on meteorological_corrections, sound_power_anechoic, sound_power_reverberation and sound_power_comparison; the fields AtmosphericAttenuation.pressure, AircraftBandAttenuation.pressure and ReportMetadata.pressure, all in kPa |
static_pressure_kpa= and .static_pressure_kpa |
static_pressure= on alternating_airflow_resistance, barometric_pressure= on sound_power_intensity_precision, atmospheric_pressure= on enclosed_gas_stiffness and floating_floor_resonance |
static_pressure_pa= |
atmospheric_pressure= on air_density_iso (now air_density_iso10534) and air_density_astm (now air_density_astm_e2611) |
static_pressure_kpa= on air_density_iso10534 and air_density_astm_e2611 |
atmospheric_pressure= on johnson_champoux_allard and the slow-sound functions |
the fluid= they take now, which carries its own static pressure |
humidity=, relative_humidity= |
relative_humidity_percent= |
diameter= and its thirteen compounds |
diameter_m= |
angle=, angles=, bank_angle=, path_angle=, grazing_angle=, launch_angles= |
_deg= or _rad=, whichever the function reads |
runway_gradient= |
runway_gradient_ratio= |
sound_speed_gradient= |
sound_speed_gradient_per_s= |
The pressure of the medium has one name. static_pressure_kpa or
static_pressure_pa is the absolute pressure of the medium a quantity is
computed in (the air, a gas or sea water), in the unit its clause writes it in; a stream pressure measured
in a duct is a gauge pressure and says so (static_gauge_pressure_pa), or is
the static_pressure_pa of velocity_pressure_pa and total_pressure, whose
formulas read it that way. atmospheric_pressure_pa is kept only for the
outside atmosphere where the same method measures a stream pressure beside it:
pipe_transmission_loss, DownstreamPipe, normal_air_density and
gas_density_kg_m3.
One case is worth naming because it was a trap rather than an inconvenience.
critical_angle was a field in radians on one result and a parameter in
degrees on the two functions one screen below it, which is the same word for
two things 57 times apart. It is critical_angle_rad on the result and
critical_angle_deg on the parameters now.
transmission_loss= became propagation_loss= only in the underwater sonar
and numerical-propagation results. ReactiveSilencerResult and
SoundReductionResult still call theirs transmission_loss=, correctly:
that is what the standards behind them call it.
The EN 29052-1 functions of materials follow the same rule, with the unit
of each quantity at the end of its name:
| 3.3.0 | 4.0 |
|---|---|
apparent_dynamic_stiffness(resonant_frequency=, total_mass_per_area=) |
resonant_frequency_hz=, total_mass_per_area_kg_m2= |
enclosed_gas_stiffness(thickness=) |
thickness_m= |
installed_dynamic_stiffness(apparent_stiffness, airflow_resistivity, gas_stiffness=) |
apparent_stiffness_n_m3, airflow_resistivity_kpa_s_m2= by name only, gas_stiffness_n_m3= |
natural_frequency(dynamic_stiffness=, mass_per_area=) |
dynamic_stiffness_n_m3=, mass_per_area_kg_m2= |
floating_floor_resonance(resonant_frequency=, total_mass_per_area=, floor_mass_per_area=, airflow_resistivity=, thickness=) |
resonant_frequency_hz=, total_mass_per_area_kg_m2=, floor_mass_per_area_kg_m2=, airflow_resistivity_kpa_s_m2=, thickness_m= |
The airflow resistivity is the one that earns the keyword. EN 29052-1
thresholds it in kPa·s/m², and every other flow resistivity in the library is
in Pa·s/m², a unit a thousand times smaller, so a Pa·s/m² figure passed by
position landed in the wrong branch of clause 8.2 without a word; it is
written by name now. And below 100 kPa·s/m², installed_dynamic_stiffness no
longer reads a missing gas term as zero: 3.3.0 returned $s'\mathrm{t}$ from
installed_dynamic_stiffness(20e6, 50.0), Formula 6 with its second term
dropped, and 4.0 raises and asks for $s'\mathrm{a}$.
The ISO 13472-1 functions of materials spell the microphone out and give
both heights in metres, and two temperatures say which scale they are on:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
mic_height= and source_height= on every ISO 13472-1 function of materials that takes them, and on plot_insitu_geometry |
microphone_height_m=, source_height_m= |
InsituAbsorptionResult.mic_height and .source_height |
.microphone_height_m and .source_height_m |
GasStream.inlet_temperature_k, in kelvin |
inlet_temperature_c, in degrees Celsius: convert the number, as the section above shows |
RoadEmissionCoefficients.temperature_k, the CNOSSOS-EU $K_m$ in dB per degree, which read as a temperature in kelvin |
temperature_coefficient_db_per_k: a coefficient per degree is per kelvin, the same number as per degree Celsius |
Lengths take their unit where a second unit competes for the word. A thickness is in metres on a layer and in millimetres on the catalogue row it is read from, a spacing is metres between two microphones or hertz between two spectral lines, a height is metres above the ground and decibels on a coincidence plateau, and the aircraft package reads its noise-power-distance tables in feet and computes in metres:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
thickness= on PorousLayer, AirLayer, PerforatedPlateLayer, MicroperforatedPlateLayer, PoroelasticLayer, TransferMatrix, BarrierInsertionLoss and every function that took one: the Biot, four-microphone, perforated-plate, airflow-resistance, resilient-layer, floor-covering, panel, flanking, structure-borne, SEA and point-mobility functions and the geometry plot helpers; thickness1= and thickness2= on junction_transmission, junction_wave_parameters, right_angle_transmission_coefficient, point_connection_coupling_loss_factor, JunctionTransmissionResult and plot_junction_geometry; wall_thickness=, lining_thickness=, plate_thickness=, splitter_thickness=; specimen_thickness= on plot_dynamic_stiffness_rig and sample_thickness= on plot_impedance_tube_geometry |
thickness_m=, thickness1_m=, thickness2_m=, wall_thickness_m=, lining_thickness_m=, plate_thickness_m=, splitter_thickness_m=, specimen_thickness_m=, sample_thickness_m= |
spacing= on sound_intensity and IntensityResult, the IEC 61043 functions and IntensityInstrumentComplianceResult, and the impedance-tube functions and ImpedanceTubeResult |
spacing_m= |
line_spacing= on the ISO/PAS 20065 tone functions and ToneAudibilityResult; ZoomFFTResult.bin_spacing |
line_spacing_hz=; .bin_spacing_hz |
height=, heights=, source_height=, receiver_height=, barrier_height=, max_height=, height_step=, slit_height=, plenum_height=, drop_height= and the other heights in metres, height_fundamental_frequency(height=) among them |
the same name ending in _m |
plateau_height= on plateau_transmission_loss and SoundReductionResult |
plateau_height_db= |
distance=, distances= and their compounds in aircraft: npd_level, npd_curve, event_level, noise_contour, noise_fraction, AnpNpdCurves, AnpDatabase, RotorcraftHemisphere, hover_ring_hemisphere, the rotorcraft propagation functions and their results |
distance_m=, distances_m=, reference_distance_m=, horizontal_distance_m=, scaled_distance_m=, query_distances_m=, table_distances_m |
ReportMetadata(mic_spacing=, thickness=) |
microphone_spacing_m=, thickness_m= |
center=, width= and wavelength= on FDTD2D.add_plane_wave |
center_m=, half_width_m= (the 1/e half-width, as GaussianPulse.half_width_s is in time) and wavelength_m=, beside the widths the engine counts in cells |
Thirteen lengths are written by name now as well, because they carry a default
and the name is the only place the unit shows: npd_curve(query_distances_m=),
static_airflow_resistance(thickness_m=), the distance_m, spacing_m and
source_height_m fields of RotorcraftHemisphere, IntensityResult and
RoadEmissionResult, the thickness1_m and thickness2_m that
JunctionTransmissionResult keeps for its drawing, and the ISO 13472-1
source_height_m and microphone_height_m of geometric_spreading_factor,
geometric_spreading_factor_angle and InSituAbsorptionResult. The duct
section that duct_path reads is {"width_m": a, "height_m": b}, and
TABLE_D1_QUANTITIES names thickness_m among the quantities a Table D.1 row
is described by. The catalogue rows keep thickness_mm, the unit the catalogue
holds every row in whatever unit its source prints, and
vertical_directivity(height=1) keeps its name, because 1 or 2 picks a source
line and is not a length.
A rate, a speed and a phase carry their unit too. An absorption coefficient in dB/km beside the dimensionless absorption coefficient of a wall, a vehicle speed in km/h beside a wind speed in m/s and a flight speed in knots, and a phase in radians on a transfer function beside one in degrees on a calibration record were each the same word for two things:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
absorption_coefficient on PropagationLossResult, GaussianBeamResult and DetectionRangeResult, in dB/km |
absorption_db_per_km |
air_absorption_coefficient= on sound_power_anechoic and meteorological_corrections, in dB/m |
air_absorption_db_per_m=, the spelling CalibrationConditions uses |
AtmosphericAttenuation.attenuation_coefficient, in dB/m |
.attenuation_db_per_m |
air_attenuation= on sabine_reverberation_time, eyring_reverberation_time, millington_sette_reverberation_time, fitzroy_reverberation_time, arau_puchades_reverberation_time, reverberation_time_models and image_source_rir, and SoundAbsorptionMeasurement.air_attenuation |
air_attenuation_per_m |
attenuation= on tube_wavenumber and two_microphone_impedance, in Np/m |
attenuation_np_per_m= |
attenuation_source= and attenuation_receiving= on plenum_flanking_reduction_index |
attenuation_source_per_m= and attenuation_receiving_per_m= |
speed= on road_rolling_noise, road_propulsion_noise, road_vehicle_sound_power, aerodynamic_sound_power and roughness_to_frequency; RoadTraffic.speed, RailwayVehicle.speed and RoadSurfaceCoefficients.speed_range; railway_source_power(minimum_speed=), all in km/h |
speed_kmh, speed_range_kmh and min_speed_kmh=; RailwayVehicle takes speed_kmh= by name |
reference_speed= on event_level, noise_contour and duration_correction, and segment_speed= on duration_correction |
reference_speed_m_s= and segment_speed_m_s= |
FlightPathKinematics.airspeed and .ground_speed, in m/s |
.airspeed_m_s and .ground_speed_m_s |
ground_speed= on linear_sound_speed_profile, log_linear_sound_speed_profile, ray_curvature_radius and shadow_zone_distance, the speed of sound at the ground |
ground_speed_of_sound= |
RayTraceResult.profile_speeds |
.profile_speeds_of_sound |
blade_passing_frequency(rotational_speed=) |
rotational_speed_rpm= |
.phase on FrequencyResponseResult, CrossSpectralDensityResult, PhaseDecompositionResult, EnvelopeResult and MobilityResult; .minimum_phase and .excess_phase on PhaseDecompositionResult; CrossSpectralDensityResult.phase_std, all in radians |
.phase_rad, .min_phase_rad, .excess_phase_rad and .phase_standard_deviation_rad |
residual_index_from_phase_mismatch(phase_mismatch=) and IntensityInstrumentComplianceResult.phase_mismatch(), in degrees |
phase_mismatch_deg= and .phase_mismatch_deg() |
A name is also one spelling inside a package. Where a word was public both bare and with its unit in the same package, it now keeps its unit if a second unit competes for it, as in the first table below, and drops it if the word only ever had the one, as in the table of "One spelling per concept":
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
RotorcraftHemisphere.azimuth and .polar, RotorcraftEventResult.azimuth and .polar, in degrees |
.azimuth_deg and .polar_deg, as hemisphere_source_level takes them |
sae_band_attenuation(path_length=) (now band_attenuation_arp5534) and AircraftBandAttenuation.path_length |
path_length_m |
gap= on double_wall_transmission_loss, mass_spring_mass_resonance and plot_double_wall_geometry, and SoundReductionResult.gap, in metres |
gap_m, beside the gap_mm of a joint series |
HeavyImpactSourceSpec.tolerance and HeavyImpactSourceCheck.tolerance, in dB |
.tolerance_db |
LoudspeakerCharacteristics.input_voltage and loudspeaker_characteristics(input_voltage=), MicrophoneNoise.voltage |
input_voltage_v and voltage_v, as the induction-loop records spell them |
LoudspeakerCharacteristics.rated_frequency_range, MicrophoneCharacteristics.reference_frequency and microphone_characteristics(reference_frequency=) |
rated_frequency_range_hz and reference_frequency_hz, as the headphone records spell them |
SweptSineDistortionResult.thd, a ratio |
.thd_ratio, beside the thd_percent of the loudspeaker and microphone records |
roughness_to_frequency(wavelengths=), in millimetres |
wavelengths_mm=, beside the wavelengths_m of an EN 15610 spectrum |
sea_water_sound_speed(salinity=, depth=, latitude=) |
salinity_psu=, depth_m= and latitude_deg=, as sea_water and sea_water_density take them |
depth= on metadiffuser_reflection, metadiffuser_polar_response, metadiffuser_diffusion_spectrum and plot_metadiffuser_panel_geometry, and MetadiffuserResult.depth, in metres |
depth_m, beside the depth_mm of a ceiling specimen |
DynamicStiffnessResult.resonant_frequency, .apparent_stiffness, .dynamic_stiffness, .gas_stiffness and .floor_mass_per_area |
.resonant_frequency_hz, .apparent_stiffness_n_m3, .dynamic_stiffness_n_m3, .gas_stiffness_n_m3 and .floor_mass_per_area_kg_m2, as the EN 29052-1 functions take them beside the MN/m³ the standard prints |
johnson_champoux_allard(viscous_length=, thermal_length=), in metres |
viscous_length_m= and thermal_length_m=, beside the micrometres of a catalogue row |
CorrelationResult.duration and correlation_random_error(duration=), in seconds |
duration_s, beside the duration_hours of lex_8h |
LevelCrossingResult.duration and PeakStatisticsResult.duration, in seconds |
.duration_s, beside the duration_ms of an IEC 61672-1 toneburst |
RigidMassCalibrationResult.tolerance and .deviation, and tolerance= on seat_transmission and mean_of_test_runs, relative figures |
relative_tolerance and relative_deviation |
LabAirborneInsulationResult.absorption and LabImpactInsulationResult.absorption, the area A in m² |
.absorption_area |
HelmholtzResonator(neck_length=, neck_side=, cavity_length=, cavity_side=); lattice_step= on slit_helmholtz_absorber, helmholtz_resonator_impedance, critical_coupling_design, plot_slit_absorber_geometry and SlitResonatorAbsorberResult; critical_coupling_design(cavity_length_bounds=) and rectangular_duct_properties(side=) |
the same names ending in _m |
width= on plane_wave_limit, rectangular_duct_cut_on, elbow_insertion_loss, lined_rectangular_duct_attenuation, unlined_rectangular_duct_attenuation and hydraulic_diameter |
width_m=, beside their height_m= |
width= on outdoor_attenuation, typical_element_mobility, slit_transmission_coefficient, slit_resonance_frequencies and plot_aperture_geometry, and ApertureTransmissionResult.width, in metres |
width_m, beside the height_m of a facade and the joint_width_mm of a joint |
AircraftBandAttenuation.coefficient, in dB/m |
.coefficient_db_per_m, beside the coefficient_db_per_100m of an ARP 866A result |
LoudspeakerCharacteristics.rated_impedance, .minimum_impedance and .impedance_modulus, and loudspeaker_characteristics(rated_impedance=); rated_impedance and minimum_load_impedance on MicrophoneCharacteristics and MicrophoneElectrical, and microphone_characteristics(rated_impedance=, minimum_load_impedance=) of 3.3.0, all in ohms |
the same names ending in _ohm, as the headphone and induction-loop records spell them beside the mechanical impedances of a piston, with a minimum spelled min_ (rated_impedance_ohm, min_impedance_ohm, impedance_modulus_ohm, min_load_impedance_ohm); the microphone pair is given as microphone_characteristics(..., electrical=MicrophoneElectrical(rated_impedance_ohm=..., min_load_impedance_ohm=...)) |
flow_resistivity= on ground_effect, atmospheric_parabolic_equation, delany_bazley, miki, johnson_champoux_allard and decoupling_frequency, PorousMediumResult.flow_resistivity, and barrier_insertion_loss(ground_flow_resistivity=), in Pa s/m² |
flow_resistivity_pa_s_m2 and ground_flow_resistivity_pa_s_m2, beside the kPa s/m² of the IEC TS 61400-11-2 ground classes and of EN 29052-1 |
A published constant follows the same rule, and it needs it more, because a
number on its own has nothing but its name to say what it is in: 10.0 is
hertz, decibels or a count. A constant that holds one number ends in its unit,
or in _DB when it is in decibels, unless it is a count, a factor or a ratio;
a table whose name says what it holds (bands, speeds, heights) ends in the
unit of that. The constants that the 3.3.0 root exported are in the table of
gone names at the end of this page; these are the rest.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
noise_control.ISO7235_GAS_CONSTANT, 287 J/(kg K) |
ISO7235_AIR_GAS_CONSTANT_J_KG_K |
noise_control.UNIVERSAL_GAS_CONSTANT, 8314 J/(kmol K) |
IEC60534_MOLAR_GAS_CONSTANT_J_KMOL_K |
noise_control.AIR_SOUND_SPEED_M_S, PIPE_SOUND_SPEED_M_S |
AIR_SPEED_OF_SOUND_M_S, PIPE_SPEED_OF_SOUND_M_S |
environment.ROAD_REFERENCE_SPEED, RAILWAY_MINIMUM_SPEED, TRAM_MINIMUM_SPEED, AERODYNAMIC_THRESHOLD_SPEED, AERODYNAMIC_REFERENCE_SPEED, all in km/h |
ROAD_REFERENCE_SPEED_KMH, RAILWAY_MIN_SPEED_KMH, TRAM_MIN_SPEED_KMH, AERODYNAMIC_THRESHOLD_SPEED_KMH, AERODYNAMIC_REFERENCE_SPEED_KMH |
environment.ROAD_REFERENCE_TEMPERATURE |
ROAD_REFERENCE_TEMPERATURE_C |
environment.ROAD_SOURCE_HEIGHT, RAILWAY_SOURCE_HEIGHTS |
ROAD_SOURCE_HEIGHT_M, RAILWAY_SOURCE_HEIGHTS_M |
environment.ROAD_OCTAVE_BANDS, RAILWAY_OCTAVE_BANDS, RAILWAY_THIRD_OCTAVE_BANDS |
the same names ending in _HZ |
building.LOW_FREQUENCY_BANDS |
LOW_FREQUENCY_PROCEDURE_BANDS_HZ, beside the environment.LOW_FREQUENCY_BANDS_HZ of another standard |
building.HEAVY_IMPACT_OCTAVE_BANDS, TABLE_F1_OCTAVE_BANDS, DB_HR_FREQUENCIES |
the same names ending in _HZ |
building.TAPPING_DROP_HEIGHT, TAPPING_HAMMER_RADIUS, TAPPING_HAMMER_MASS, TAPPING_IMPACT_RATE |
TAPPING_DROP_HEIGHT_M, TAPPING_HAMMER_RADIUS_M, TAPPING_HAMMER_MASS_KG, TAPPING_IMPACT_RATE_HZ |
building.LOW_FREQUENCY_VOLUME_LIMIT |
LOW_FREQUENCY_VOLUME_LIMIT_M3 |
hearing.AUDIOMETRIC_FREQUENCIES, PROTECTOR_OCTAVE_BANDS |
AUDIOMETRIC_FREQUENCIES_HZ, PROTECTOR_OCTAVE_BANDS_HZ |
building.MINIMUM_MULTI_JUNCTION_KIJ, −5 dB |
MIN_MULTI_JUNCTION_KIJ |
broadcast.DBQPS_REFERENCE, 0.775 V |
DBQPS_REFERENCE_V |
electroacoustics.CARDIOID_RELATIVE_DIRECTIVITY, DEFAULT_STABILITY_MARGIN, both in dB |
the same names ending in _DB |
environment.REFERENCE_JOINT_DENSITY, joints per metre |
REFERENCE_JOINT_DENSITY_PER_M |
noise_control.ISO7235_ABSOLUTE_ZERO_OFFSET, 273 K |
ISO7235_ABSOLUTE_ZERO_OFFSET_K |
psychoacoustics.ERB_C1, in Hz, and ERB_C2, per Hz |
ERB_C1_HZ, ERB_C2_PER_HZ |
room.COMMUNICATION_SNR, PRIVACY_SNR, both in dB |
the same names ending in _DB |
vibration.UNCONSTRAINED_BELOW, the −100 % of ISO 8041-1 |
UNCONSTRAINED_BELOW_PERCENT, beside CENTRAL_TOLERANCE_PERCENT and the rest |
The gas constants show why a constant needs its unit as much as a parameter
does. Two constants of one package shared the words "gas constant" for
287 J/(kg K) and 8314 J/(kmol K), and fluids publishes 8.314 J/(mol K) as a
third: three figures 29 and 1000 apart under one name. Each now carries its
whole unit.
A time signal that is one physical quantity is named for it, with its unit,
as velocity_mm_s already was on the DIN 4150 and DIN 45669 functions; a
signal in any unit is x. This only changes a call that wrote the signal by
name:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
pressure= on underwater.sound_pressure_level, peak_sound_pressure_level, sound_exposure_level, pile_strike_metrics, single_strike_sel and strike_sel_spectrum, and PileStrikeResult.pressure |
pressure_pa |
acceleration= on vibration.acceleration_dose, spinal_response and multiple_shock_assessment |
acceleration_m_s2= |
force= on building.impact_force_exposure_level and vibration.injected_power |
force_n= |
Conditions and flags are written by name #
An ambient or medium condition or a calibration factor that carries a default,
and every public boolean flag, are keyword-only. The conditions are the
temperature, the humidity and the static pressure, the speed of sound and the
density of the medium, and the three ground factors of ISO 9613-2. The rule exists because the call site is
where the meaning is lost: air_attenuation(freqs, 20.0, 50.0, 101.325) is a
temperature, a humidity and a pressure in an order nobody remembers, and
bank.filter(x, True) says nothing about which of five flags was thrown. A
choice of method or of band set and a count (mode, method, fraction,
n, seed) are options, not conditions, and the rule leaves them where they
are.
The failure is loud, which is the point:
import numpy as np
from phonometry.signals import leq
x = np.random.default_rng(1).standard_normal(4800) * 0.01
try:
leq(x, 48000)
except TypeError as error:
print(error) # leq() takes 1 positional argument but 2 were given
That call is worth a second look. leq never had an fs, because an energy
average does not need one, so in 3.3.0 the 48000 silently bound to
calibration_factor and the answer came back 93.6 dB high with no complaint.
Now it is a TypeError, which is what it always should have been.
print(round(float(leq(x, dbfs=True)), 3))
These took a condition or a calibration factor by position until now:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
signals.sound_exposure(x, fs, 8.0, cal) and lex_8h(x, fs, 8.0, cal) |
sound_exposure(x, fs, duration_hours=8.0, calibration_factor=cal) |
psychoacoustics.sharpness_din(x, fs, "free", "din", cal) |
sharpness_din(x, fs, "free", "din", calibration_factor=cal) |
environment.ground_attenuation(d, hs, hr, bands, gs, gm, gr) |
ground_attenuation(d, hs, hr, frequencies=bands, ground_source=gs, ground_middle=gm, ground_receiver=gr), and projected_distance= by name |
the speed of sound by position on IntensityInstrumentComplianceResult.phase_mismatch_deg, emission.phase_mismatch_from_residual_index, residual_index_from_phase_mismatch, environment.fresnel_number, spherical_reflection_coefficient, room.reflection_density, materials.reflected_path_delay, spot_tube_upper_frequency and spot_microphone_spacing_bounds |
speed_of_sound= |
noise_control.LiquidPipe(d, t, rho, c, rho_air, c_air) |
LiquidPipe(internal_diameter_m=d, wall_thickness_m=t, density=rho, speed_of_sound=c, air_density=rho_air, air_sound_speed=c_air) |
underwater.FluidSeabed(rho, c, rho_water) |
FluidSeabed(density=rho, speed_of_sound=c, water_density=rho_water) |
io.Signal(data, fs, cal) |
io.Signal(data, fs, calibration_factor=cal), and channel_labels, provenance and source by name |
A parameter whose name carries its unit and that has a default is written by
name too. noise_signal(fs, 2.0) reads as two seconds only to someone who
remembers the order, and the _s that says so is on the parameter, not on the
call:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
signals.noise_signal(fs, 2.0), speech.stipa_signal(fs, 18.0) |
noise_signal(fs, duration_s=2.0), stipa_signal(fs, duration_s=18.0) |
underwater.ship_source_spectrum(12.0, 100.0) |
ship_source_spectrum(12.0, length_m=100.0) |
the per-sample duration by position on hearing.job_based_exposure |
sample_duration_hours= |
A frequency axis is written by name as well, wherever it sits beside the values
it labels. Two arrays of one length bind either way round without a complaint,
so a call that swaps them answers on the wrong axis instead of failing; the API
reference itself carried weighted_rating_extended(freqs, r) and
weighted_impact_rating_extended(freqs, ln) with the frequencies where the
levels go. The values stay positional, in the order they
had, and the axis goes behind the *:
import numpy as np
from phonometry import room, signals
frequencies = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0, 8000.0])
levels = np.array([62.0, 56.0, 50.0, 45.0, 41.0, 38.0, 36.0, 35.0])
print(room.noise_criterion(levels, frequencies=frequencies).rating)
smoothed = signals.fractional_octave_smoothing(levels, frequencies=frequencies, domain="db")
print(smoothed.shape)
try:
room.noise_criterion(levels, frequencies)
except TypeError as error:
print(error) # noise_criterion() takes 1 positional argument but 2 were given
The axis is frequencies, frequencies_hz on the two underwater functions
whose formulas are printed in kHz, and frequency where a function evaluates
one frequency or many. An array whose name ends in one of them follows the same
rule: the tone_frequencies beside the tone levels of ISO/PAS 20065, or the
critical_frequencies beside the vibration reduction indices of ISO 12354-1.
These functions took it by position until now:
aircraft:hover_ring_hemisphere,terrain_screening_adjustment.building:a_weighted_max_impact_level,apply_low_frequency_procedure,ceiling_attenuation_class,equivalent_absorption_length,impact_improvement,improvement_octave_bands,perimeter_absorption_coefficient,plate_loss_factor,reception_plate_power,reciprocity_impact_level,resonant_sound_reduction_index,structural_reverberation_time,structure_borne_power_level,tapping_machine_characteristic_power_level,tapping_machine_coupling_term,total_loss_factor,weighted_impact_rating_extended,weighted_rating_extended.electroacoustics:loudspeaker_characteristics,microphone_characteristics.emission:field_indicators,octave_band_levels,phase_mismatch_from_residual_index,precision_background_correction,residual_index_from_phase_mismatch,sound_energy_in_situ,sound_energy_reverberation,sound_power_in_duct,sound_power_in_situ,sound_power_reverberation,velocity_level_from_acceleration,verify_intensity_class.environment:assess_tonal_survey,spherical_reflection_coefficient,tonal_correction,wind_turbine_tonality.hearing:hearing_level_to_coupler_spl.materials:diffusion_spectrum,equivalent_area_uncertainty,measure_sound_absorption,one_third_octave_absorption,practical_coefficient_uncertainty,scattering_coefficient_spectrum,sound_absorption_coefficient_uncertainty.noise_control:duct_path,room_to_room_transmission,splitter_silencer_insertion_loss.psychoacoustics:analyze_spectrum,assess_tones,combined_tone_level,equal_loudness_contours,mean_narrowband_level,tone_level.room:noise_criterion,octave_pair_averages,room_criterion,room_modal_density,room_mode_count,single_number_average.signals:fractional_octave_smoothing, whosefractionis written by name now too.underwater:monopole_source_level,weighted_exposure.vibration:characteristic_phase_deviation,convert_frf,coupling_loss_factor,indirect_transfer_stiffness_result,power_injection_clf,power_injection_matrix,transfer_stiffness_indirect,verify_phase_response,verify_rigid_mass_calibration,verify_weighting,weighted_acceleration.
A positional value that came after the axis stays positional and moves up one
place: convert_frf(value, f, "mobility", "impedance") is
convert_frf(value, "mobility", "impedance", frequency=f).
A wavelength axis is written by name in the same way.
environment.roughness_to_frequency(levels, wavelengths, speed) is
roughness_to_frequency(levels, wavelengths_mm=wavelengths, speed_kmh=speed):
the levels of the roughness table stay positional, and its wavelengths are
written by name with the speed after them, so the km/h of the speed is on the
line as well. materials.standing_wave_reflection(swr, x_min1, lam) and
standing_wave_normalized_impedance(swr, x_min1, lam) take the wavelength of
each tone by name, wavelength=lam: it is a length of the same shape as the
distance to the first minimum beside it, and the two bind either way round.
A signal function takes the samples and their rate by position, and the
quantity that says what it does to them by name. These took that quantity by
position in 3.3.0, even where it is a choice, as the weighting name of
apply_weighting is, or a count, as an order is. The rate may now be left
out when the samples are a Signal, which carries its own:
| 3.3.0 | 4.0 |
|---|---|
linkwitz_riley(x, fs, 1000.0, 4) |
filters.linkwitz_riley(x, fs, frequency=1000.0, order=4), with the frequency that was freq |
parametric_eq(x, fs, sections) |
filters.parametric_eq(x, fs, sections=sections) |
zoom_fft(x, fs, 900.0, 1100.0) |
signals.zoom_fft(x, fs, f_min=900.0, f_max=1100.0) |
lifter(x, fs, 0.002) |
signals.lifter(x, fs, cutoff=0.002) |
time_synchronous_average(x, fs, 0.05) |
signals.time_synchronous_average(x, fs, period_s=0.05), the period in seconds, as its name now says |
resample_signal(x, fs, 32000) |
signals.resample_signal(x, fs, fs_new=32000) |
harmonic_distortion(x, fs, 1000.0, 2) |
electroacoustics.harmonic_distortion(x, fs, fundamental=1000.0, order=2) |
difference_frequency_distortion(x, fs, 1000.0, 1200.0) |
electroacoustics.difference_frequency_distortion(x, fs, f1=1000.0, f2=1200.0) |
modulation_distortion(x, fs, 60.0, 7000.0) |
electroacoustics.modulation_distortion(x, fs, f_low=60.0, f_high=7000.0) |
swept_sine_distortion(recorded, fs, 20.0, 20000.0, 2.0) |
electroacoustics.swept_sine_distortion(recorded, fs, f1=20.0, f2=20000.0, duration_s=2.0) |
apply_weighting(x, fs, "Wk") |
vibration.apply_weighting(x, fs, name="Wk") |
sound_intensity(p1, p2, fs, 0.012) |
emission.sound_intensity(p1, p2, fs, spacing_m=0.012) |
import numpy as np
from phonometry import io, signals
fs = 8000
x = io.Signal(np.sin(2 * np.pi * 1000.0 * np.arange(fs) / fs), fs)
try:
signals.zoom_fft(x, fs, 900.0, 1100.0)
except TypeError as error:
print(error) # zoom_fft() takes from 1 to 2 positional arguments but 4 were given
zoom = signals.zoom_fft(x, f_min=900.0, f_max=1100.0)
print(zoom.frequencies[np.argmax(zoom.amplitude)]) # 1000.0
A record you build and hand to a function is written by name the same way:
aircraft.RotorcraftHemisphere(freqs, az, po, levels) is
RotorcraftHemisphere(frequencies=freqs, azimuth_deg=az, polar_deg=po, levels=levels), and a positional call raises TypeError. A result the
library builds and another function takes whole keeps its fields where they
are, since no caller writes it field by field.
Every record you build and hand to a function takes its fields by name, not only those with an axis. These took them by position in 3.3.0 or 4.0.0rc1:
aircraft:Aerodrome,AerodynamicCoefficients,ApproachStep,DepartureStep,FlightConditionInterpolation,JetEngineCoefficients,PerformanceAircraft,PropellerEngineCoefficients,RotorcraftGround.broadcast:QuasiPeakBallistics.building:ApertureTransmissionResult,BandPath,FacadeElement,FlankingPath,HomogeneousElement,LowFrequencyProcedure,SoundReductionResult.electroacoustics:LoudspeakerDirectivity,LoudspeakerRatings,MicrophoneDirectivity,MicrophoneElectrical,MicrophoneNoise,MicrophoneOverload.emission:GradeConditions,PrecisionFieldIndicators,RoomEnvironment.environment:Barrier,DirectivityCorrection,EffectiveSoundSpeedProfile,GroundFactors,NoisePhase,PropagationGeometry,RailwayTrack,RailwayVehicle,RegulationLimits,RoadDeviceRating,RoadEmissionCoefficients,RoadSurfaceCoefficients,RoadTraffic,RollingStock,SourceEmission.filters:EQSection,FilterDesign,LevelCalibration.fluids:Fluid.hearing:ExposureResult,HMLRatingResult,SNRRatingResult,Task.io:BroadcastMetadata,SignalOrigin.materials:AbsorptionRatingResult,AirLayer,BiotWavesResult,HelmholtzResonator,MembraneLayer,MetadiffuserWell,MicroperforatedPlateLayer,PerforatedPlateLayer,PoroelasticLayer,PorousLayer,PorousMediumResult.metrology:Quantity.noise_control:DesignCriterion,DownstreamPipe,DuctElement,Expander,GasStream,LiquidPipe,LiquidStream,LiquidTrim,RegimeBoundaries,RoomToRoomResult,SourceRoom,ValveTrim.simulation:ContourPhasors,CWSource,ElasticBoundaries,ElasticRecording,ExplosionSource,ForceSource,GaussianPulse,Material,PlaneWaveSource,SignalSource.underwater:BeamFan,FluidSeabed,RayTraceResult,VolumeAbsorption,WestonSeabed.vibration:FaultFrequencyResult,FaultLine,WeightingVerification,ZoneBoundaries.
noise_control.DuctElement("Elbow", [0, 1, 2], [41, 39, 36]) is
DuctElement(label="Elbow", attenuation=[0, 1, 2], self_noise=[41, 39, 36]).
io.Signal(x, fs) is the one record that keeps its two first fields by
position: the samples and their rate are the pair every function of the
library takes that way.
One spelling per concept #
The public names had drifted into several spellings of the same quantity, and
4.0 keeps the one the majority already used. The rule for the quantities
counted in the plural is the one most of the API followed: a field or a
parameter that holds an array is frequencies, times, distances or
levels, and one that holds a single value is singular. A vectorised argument
that takes either a number or an array keeps its name. An axis carries no
unit in its name, because its unit never changes: frequencies are in
hertz, levels in decibels and the sample rate is fs on every function.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
sound_speed (control valves, silencer measurement, Weston regimes, ambient noise, FluidSeabed, ShipSourceLevelResult) |
speed_of_sound |
c= and rho= on sound_intensity, c= on the two phase-mismatch conversions, phase_mismatch() (now phase_mismatch_deg()), absorption_coefficient_uncertainty and monopole_source_level |
speed_of_sound=, density= |
speed_of_sound_m_s= on thickness_critical_frequency_product |
speed_of_sound= |
sample_rate on the FDTD SignalSource, STOIResult and impact_force_exposure_level |
fs |
sponge_width=, sponge_sides=, sponge_reflection= and .sponge_width/.sponge_sides on FDTD2D and ElasticFDTD2D |
absorbing_layer_cells=, absorbing_sides=, absorbing_layer_reflection= and .absorbing_layer_cells/.absorbing_sides, the words the run records use for the same layer, as FDTDBoundaries.absorbing_layer_cells and ElasticBoundaries.absorbing_layer_cells do; the default is still 0, no layer |
FDTD2D.plot_geometry(probes=) in metres (4.0.0rc1) |
(ix, iy) cells, as FDTDRecording.probes; each is drawn at the cell centre FDTDResult.probe_positions records, and a cell off the grid or inside an obstacle is refused as a run refuses it |
freq= on linkwitz_riley and adaptation_term_kc |
frequency= and frequencies= |
band["freq"] in the bands rows of FilterComplianceResult, WeightingComplianceResult and IntensityInstrumentComplianceResult, and between_nominals["worst_freq"] on WeightingComplianceResult |
band["frequency"] and between_nominals["worst_frequency"] |
.frequency on the results that carry a frequency axis: IntensityResult, FieldIndicators, IntensityInstrumentComplianceResult, RoomAcousticsResult, the five auditorium results, ImpedanceTubeResult, PorousMediumResult, LayeredAbsorberResult, DiffuseFieldAbsorptionResult, BiotWavesResult, SlitResonatorAbsorberResult, MetadiffuserResult, TransferMatrix, the two valve-noise results, AircraftBandAttenuation, AmbientNoiseResult, ShipTrafficSpectrum |
.frequencies |
.band_centers on the ISO 717 and ISO 11654 ratings (WeightedRatingResult, ImpactRatingResult, ExtendedWeightedRatingResult, ExtendedImpactRatingResult, AbsorptionRatingResult), .centre_frequencies on EcmaLoudness, EcmaTonality, EcmaRoughness, EcmaFluctuationStrength and MooreGlasbergLoudness, .band_frequencies on FilterComplianceResult and STOIResult, .bands_hz on RoadDeviceRating |
.frequencies, the band axis of every result |
frequency= holding an array: the flanking-transmission functions, internal_spectrum, pipe_transmission_loss, expander_noise, transfer_matrix_one_load, transfer_matrix_two_load, TransferMatrix.plot |
frequencies= |
level= and frequency= holding a band axis: apply_low_frequency_procedure, heavy_impact_octave_levels, a_weighted_maximum_impact_level, standardized_maximum_impact_level, ceiling_attenuation_class, plenum_flanking_reduction_index, single_number_average, octave_pair_averages, one_third_octave_absorption, power_injection_matrix, power_injection_clf, valve_hydrodynamic_noise, indirect_transfer_stiffness_result, and frequency_hz= on ship_source_spectrum |
levels= and frequencies= |
frequency_hz= holding an array on weighted_exposure and ocean_ambient_noise |
frequencies_hz=; the unit stays because the formulas they evaluate are printed in kHz |
.time on ZwickerLoudness, EcmaLoudness, MooreGlasbergTimeVaryingLoudness, the ECMA-418-2 tonality, roughness and fluctuation-strength results, DecayCurve, QuasiPeakResult |
.times |
.level on DecayCurve, NpdLevelResult, NoiseContourResult, RotorcraftNoiseContourResult, LowFrequencyResult, DuctPathStage, LateLateralResult, TransferStiffnessResult |
.levels |
.distance on NpdLevelResult and RotorcraftEventResult |
.distances_m |
frequencies_hz on the human-vibration instrument checks (WeightingVerification, PhaseVerification, characteristic_phase_deviation, verify_phase_response), levels_db= on operating_standard_deviation and subinterval_level |
frequencies, levels |
sound_speeds on EffectiveSoundSpeedProfile and sound_speeds= on normal_modes, ray_trace, gaussian_beams and parabolic_equation |
speeds_of_sound |
SoundSpeedProfile.sound_speed and .depth |
.speeds_of_sound and .depths |
omc_uncertainty= on sound_power_pressure and sound_energy_pressure, sigma_omc= on sound_power_anechoic, precision_uncertainty, sound_power_in_situ and sound_energy_in_situ, .sigma_omc on InSituSoundPowerResult |
sigma_omc_db |
level=, measured_level=, operational_level= on sti_from_impulse_response, stipa, sti_adjusted_for_levels and STIResult.adjusted_for_levels |
levels=, measured_levels=, operational_levels= |
.passed on AircraftSystemComplianceResult, QuasiPeakDynamicsResult, HeavyImpactSourceCheck, RigidMassCalibrationResult |
.passes, as on every other verifier |
microphone_characteristics(noise_weighting="CCIR") (3.3.0, where the weighting was a free label) and MicrophoneNoise(weighting="CCIR") (4.0.0rc1) |
noise=MicrophoneNoise(weighting="468"), the spelling weighting_filter and weighted_thd use for the ITU-R BS.468-4 curve. The weighting is "A" or "468", and microphone_characteristics refuses any other with ValueError |
atmospheric_pressure_kpa= on the ISO 9613-1 functions, atmospheric_absorption, outdoor_propagation_attenuation, AtmosphericAttenuation, AtmosphericConditions, sae_band_attenuation (now band_attenuation_arp5534), AircraftBandAttenuation, AerodromeAtmosphere, RotorcraftAtmosphere, impedance_adjustment, atmospheric_adjustment, the AnpAircraft and AnpDatabase methods, air_density_iso10534 and air_density_astm (now air_density_astm_e2611); atmospheric_pressure_pa= on enclosed_gas_stiffness and floating_floor_resonance; barometric_pressure_pa= on sound_power_intensity_precision; absolute_pressure_pa= on sea_water_density |
static_pressure_kpa= or static_pressure_pa=, the same unit |
ambient_pressure_pa= on normal_air_density |
atmospheric_pressure_pa=, the outside atmosphere beside the gauge static pressure of the duct |
environmental_ratio_from_absorption(absorption_area_m2=), running_rms_decay_time(integration_time_s=) and verify_running_rms_decay(integration_time_s=) |
absorption_area= and integration_time=, the spelling of the rest of their packages |
bending_stress(density_kg_m3=) |
density=, the spelling of the rest of vibration |
confidence= on building.insulation_coverage_factor, materials.absorption_coverage_factor, sound_absorption_coefficient_uncertainty, equivalent_area_uncertainty, practical_coefficient_uncertainty, weighted_coefficient_uncertainty, single_number_rating_uncertainty and environment.environmental_expanded_uncertainty, and UncertainValue.confidence |
coverage= and .coverage, the coverage probability of the GUM; confidence is left to the statistical confidence of an interval, as on signals.power_spectral_density |
A DecayCurve is read by name, curve.times and curve.levels, and no
longer unpacks as the pair it replaced. The FDTD solvers keep c and rho, which name the maps their
equations are written in.
A unit has one spelling too. A duration ends in _s or _hours, an angle in
_deg, a speed in kilometres per hour in _kmh and one in knots in _kt, a
decay rate in _db_per_s; _seconds, _degrees, _km_h, _knots, _db_s
and an _h that means hours appear nowhere in the public API any more.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
vibration.phase_tolerance_degrees |
vibration.phase_tolerance_deg |
ToneBurstResult.burst_seconds |
.burst_s |
wind_speed_knots= on ocean_ambient_noise and wind_noise_spectrum, and AmbientNoiseResult.wind_speed_knots |
wind_speed_kt, the spelling the aircraft speeds use |
speed_knots= on ship_source_spectrum, and ShipTrafficSpectrum.speed_knots |
speed_kt |
GasStream.molecular_mass, in kg/kmol |
GasStream.molar_mass_kg_kmol, the name the fluids catalogue gives its molar_mass_kg_mol per mole |
A word is written whole: ref is reference in every public name that
abbreviated it. SPL, SEL, SNR and RMS stay as they are, terms of art like
L_max.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
levels_ref=, background_levels_ref= and lw_ref= on sound_power_comparison and sound_energy_comparison (3.3.0), and on sound_power_in_situ and sound_energy_in_situ (4.0.0rc1) |
reference_levels=, reference_background_levels= and reference_sound_power_levels=, the last as high_frequency_sound_power_comparison spells it |
InSituSoundPowerResult.background_correction_ref, .sound_power_level_ref and .sound_energy_level_ref |
.reference_background_correction, and .sound_power_level_at_reference_conditions and .sound_energy_level_at_reference_conditions: the levels with the Annex C correction (C2, to the reference meteorological conditions), not those of the reference source |
metrology.sensitivity(ref_signal=) |
reference_signal= |
A standard's designation is in a name only where it tells two things apart, and then it is written one way: the body joined to its number, first in a constant or a class and last in a function. Where the module already names the standard, the designation is gone.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
sae_band_attenuation |
aircraft.band_attenuation_arp5534, the document it follows |
itu_r_468_weighting |
electroacoustics.weighting_bs468 |
air_density_astm and speed_of_sound_astm, and plane_wave_frequency_range_astm (4.0.0rc1) |
materials.air_density_astm_e2611, speed_of_sound_astm_e2611 and plane_wave_frequency_range_astm_e2611, beside air_density_iso10534 |
noise_control.VDI2081_SPECTRAL_CORRECTION |
noise_control.SPECTRAL_CORRECTION: the package has no other spectral correction to tell it from, and its own text cites VDI 2081 Part 2 |
building.EN_12354_AIR |
building.EN12354_AIR |
An identifier is spelled in American English, and in situ is spelled
in_situ. A caller types every name, so center_frequency on one function
and centre_frequency on the next was a TypeError to look up. The values a
caller types are held to it too: a Literal choice, a default, the key of a
published table and a string of a published tuple of choices. catalogue
keeps its spelling: it is an American variant too, every name writes it the
same way, and it is the file format of your own catalogues. A string a source
prints keeps its print, which is why the CNOSSOS surface below is still
"optimised brushed down concrete". The closed choices of the FDTD engines
and their records are typed Literal too, a side, a recorded field, a plane
wave's travel and a force's axis, so a type checker refuses
free_sides="Top" before the run; nothing changes at run time.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
materials.insitu_reflection_factor, insitu_absorption_from_reflection, insitu_absorption_coefficient, insitu_absorption_spectrum, plot_insitu_geometry and InsituAbsorptionResult |
in_situ_reflection_factor, in_situ_absorption_from_reflection, in_situ_absorption_coefficient, in_situ_absorption_spectrum, plot_in_situ_geometry and InSituAbsorptionResult, as the other in-situ names of the library were already spelled |
centre_frequency on critical_bandwidth, tonal_audibility, assess_tonal_audibility and TonalAssessmentResult |
center_frequency |
centre= on room.filter_bandwidth and room.source_directivity_limit |
center= |
location="centre" on the infinite plate and beam point mobilities and impedances of vibration |
location="center" |
.unfavourable_sum on WeightedRatingResult, ImpactRatingResult and AbsorptionRatingResult |
.unfavorable_sum |
vibration.storey_fundamental_frequency(storeys), STOREY_FREQUENCY_MIN_STOREYS, STOREY_FREQUENCY_NUMERATOR_HZ, STOREY_PERIOD_COEFFICIENT_S |
vibration.story_fundamental_frequency(n_stories), STORY_FREQUENCY_MIN_STORIES, STORY_FREQUENCY_NUMERATOR_HZ, STORY_PERIOD_COEFFICIENT_S |
storeys= and the model "storeys" on fundamental_period, fundamental_frequency and estimate_fundamental_frequency |
n_stories= and the model "stories" |
draught= on underwater.monopole_source_level |
draft_m=, which says its unit as well |
procedure="aeroplane" on aircraft.effective_perceived_noise_level |
procedure="airplane", still the default |
urbanisation= on environment.outdoor_quality_objectives |
urbanization= |
vapour_pressure_pa on the IEC 60534-8-4 functions of noise_control (differential_pressure_ratio, cavitation_differential, jet_strouhal_number, stage_conditions, last_stage_differential) and on LiquidStream |
vapor_pressure_pa |
"water_vapour_mole_fraction" in the composition of fluids.air() |
"water_vapor_mole_fraction" |
building.DB_HR_NORMALISED_SPECTRA, environment.NORMALISED_RAILWAY_NOISE_SPECTRUM_DB and environment.NORMALISED_TRAFFIC_NOISE_SPECTRUM_DB |
DB_HR_NORMALIZED_SPECTRA, NORMALIZED_RAILWAY_NOISE_SPECTRUM_DB and NORMALIZED_TRAFFIC_NOISE_SPECTRUM_DB |
simulation.ALUMINIUM |
simulation.ALUMINUM |
RoadSurface.OPTIMISED_BRUSHED_DOWN_CONCRETE |
RoadSurface.OPTIMIZED_BRUSHED_DOWN_CONCRETE, whose value is still the "optimised brushed down concrete" that CNOSSOS-EU Table F-4 prints |
A word has one spelling as well. An acronym is written in capitals inside a
class name, as EPNLResult and STIResult always were; Ecma, which is the
name the organisation gives itself and not an acronym, is the exception
(EcmaLoudness). mic, lab and std are spelled out. A count is
n_<plural>, and a limit on one is min_n_ or max_n_ (min_n_records,
max_n_arrivals); a duration names its quantity before its unit, never the
unit alone (exposure_duration_years, duration_s, period_hours), with
the minute spelled out (assessment_period_minutes) because a trailing _min
is a minimum, and a class number, an axis, a number of decimals and a length counted in samples
are not counts. minimum
and maximum are written min and max in every public name, MIN and MAX
in a constant and Min and Max in a class, as numpy, SciPy, scikit-learn and
Matplotlib write them, terms of art included: the maximum and minimum levels
Lmax and Lmin are max_level and min_level (never a bare max_db), the
takt maximum of DIN 45669-1 and DIN 4150-2 is TAKT_MAX_FACTOR and the
minimum-phase reconstruction is min_phase. A confidence bound is
confidence_lower or confidence_upper. A function that reads a time
signal takes it first, as x, the name octave_filter(x, fs) and the rest
of the signal functions always used; called by position, nothing changes. The
3.3.0 top-level names among these are in the table of names that are gone.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
building.DbHrAssessment, DbHrCheck, DbHrGlobalIndexResult and DbHrRequirement, noise_control.HvacWarning, underwater.StrikeSelSpectrum |
DBHRAssessment, DBHRCheck, DBHRGlobalIndexResult, DBHRRequirement, HVACWarning, StrikeSELSpectrum |
the module building.measurement.lab_insulation |
building.measurement.laboratory_insulation; importing from building is unchanged |
HMLRatingResult.subject_h, .subject_m and .subject_l |
.subject_high, .subject_medium and .subject_low, the values per subject beside high, medium and low |
.std on TrendTestResult and StationarityTestResult, TimeDelayResult.delay_std |
.standard_deviation, .delay_standard_deviation |
StationarityTestResult.count |
.trend_statistic, the statistic of the trend test it ran |
num_points= on verify_filter_class, and FilterComplianceResult.num_points |
n_points |
AnpAircraft.num_engines and PerformanceAircraft.engines |
ANPAircraft.n_engines and PerformanceAircraft.n_engines |
blade_count= on fan_sound_power, and the blades of blade_passing_frequency |
n_blades |
count= on precision_positions |
n_positions= |
count= on circular_duct_cut_on and rectangular_duct_cut_on, and WestonRegimeBoundaries.mode_count |
n_modes |
count= on diffuser_sound_power |
n_devices= |
harmonics= on gear_mesh_frequencies and blade_pass_frequencies, and the count of FaultFrequencyResult.harmonics |
n_harmonics |
SawtoothBurstTest.burst_count |
.n_bursts |
room.MAXIMUM_DIRECTIVITY_STEP_DEG, MINIMUM_BANDWIDTH_TIME_PRODUCT, MINIMUM_DETECTOR_MULTIPLE and MINIMUM_REFERENCE_DISTANCE_M, noise_control.MAXIMUM_PASSAGE_ASPECT, MINIMUM_FLOW_RATES and MINIMUM_PRESSURE_DIFFERENCE_PA, emission.MINIMUM_BACKGROUND_MARGIN_DB |
MAX_DIRECTIVITY_STEP_DEG, MIN_BANDWIDTH_TIME_PRODUCT, MIN_DETECTOR_MULTIPLE, MIN_REFERENCE_DISTANCE_M, MAX_PASSAGE_ASPECT, MIN_FLOW_RATES, MIN_PRESSURE_DIFFERENCE_PA, MIN_BACKGROUND_MARGIN_DB |
OperatingLine.maximum_deviation, maximum_open_loop_gain and maximum_level_at_microphone on FeedbackStabilityResult, maximum_reduction_db= on end_reflection_loss, LoudspeakerCharacteristics.minimum_impedance, minimum_load_impedance on MicrophoneCharacteristics and MicrophoneElectrical, DiscretePointIntensityResult.minimum_positions, minimum_speed= on railway_source_power |
max_deviation, max_open_loop_gain, max_level_at_microphone, max_reduction=, min_impedance_ohm, min_load_impedance_ohm, min_positions, min_speed_kmh= |
building.a_weighted_maximum_impact_level, standardized_maximum_impact_level, AWeightedMaximumImpactResult and StandardizedMaximumImpactResult |
a_weighted_max_impact_level, standardized_max_impact_level, AWeightedMaxImpactResult and StandardizedMaxImpactResult: max and min in every public name, terms of art included |
room.minimum_reliable_reverberation_time and minimum_receiver_positions |
min_reliable_reverberation_time and min_receiver_positions |
PhaseDecompositionResult.minimum_phase_response |
.min_phase_response |
maximum_levels= on aircraft.event_level and noise_contour |
max_levels= |
ci_lower and ci_upper on SpectralDensityResult and MultitaperSpectralDensityResult |
confidence_lower and confidence_upper, as on MethodBSummary |
elements= on low_frequency_element_normalized_difference, and LowFrequencyElementResult.elements |
n_elements |
orders= on slit_resonance_frequencies, and the junctions of multi_junction_adjustment |
n_orders= and n_junctions |
open_microphones= on feedback_stability and open_microphone_correction, and FeedbackStabilityResult.open_microphones |
n_open_microphones |
events= on sound_energy_pressure, mean_single_event_level, sound_energy_in_situ, sound_energy_reverberation and sound_energy_comparison, and .events on SoundEnergyResult and ReverberationSoundEnergyResult |
n_events |
reflecting_planes= on measurement_positions, sound_power_pressure and sound_energy_pressure |
n_reflecting_planes= |
.positions on DiscretePointIntensityResult, and .positions, .subset_positions and .additional_positions on PartialPowerConcentration |
.n_positions, .n_subset_positions and .n_additional_positions |
RollingStock.axles, VehicleDescriptor.axles and the axles of rolling_sound_power |
n_axles |
sweep_points= on verify_weighting_class, and WeightingComplianceResult.sweep_points |
n_sweep_points |
AssumedProtectionResult.subjects |
.n_subjects |
io.AudioFileInfo.channels and .frames |
.n_channels and .n_samples, the samples per channel, as on Signal |
quadrature_points= on diffuse_field_absorption, and sum_terms= on helmholtz_resonator_impedance and rectangular_duct_properties |
n_quadrature_points= and n_sum_terms= |
repetitions= on predict_diffuser_polar_response, predicted_diffusion_spectrum, metadiffuser_diffusion_spectrum, metadiffuser_polar_response and plot_qrd_geometry, and DiffuserPolarResponse.repetitions |
n_repetitions |
cycles= and repetitions= on signals.tone_burst, ToneBurstResult.cycles and .repetitions, and cycles= on vibration.sawtooth_burst and signal_burst_indications |
n_cycles and n_repetitions |
trials= on metrology.monte_carlo, and MonteCarloResult.trials |
n_trials |
the passages of silencer_self_noise, valve_style_modifier, multihole_incipient_cavitation_ratio and uniform_passage_style_modifier, and the stages of stage_level_correction |
n_passages and n_stages |
the steps of FDTD2D.run and ElasticFDTD2D.run, and max_arrivals= on underwater.eigenrays |
n_steps and max_n_arrivals= |
simulation.ContourProbe.samples and ContourProbe(sim=...) |
.n_samples, read-only, and engine= |
record_every= and decimate= on FDTD2D.run and ElasticFDTD2D.run, by position or by name |
snapshot_every= and snapshot_decimation=, the names FDTDRecording and ElasticRecording take for the same two counts, and like them keyword-only: run(400, 10, 2) is run(400, snapshot_every=10, snapshot_decimation=2) |
fdtd_simulation(probes=..., snapshot_every=..., snapshot_decimation=...) |
fdtd_simulation(FDTDRun(..., recording=FDTDRecording(probes=..., snapshot_every=..., snapshot_decimation=...))): what an acoustic run records is one record, the recording of the run, as an elastic run's is one ElasticRecording; a run without one records only its time axis, as before |
fdtd_simulation(c, dx, duration, sources=..., ...) and elastic_fdtd_simulation(c_p, c_s, dx, duration, sources=..., rho=..., ...) |
fdtd_simulation(FDTDRun(c=c, dx=dx, duration_s=duration, sources=..., boundaries=simulation.FDTDBoundaries(sides=..., absorbing_layer_cells=...), ...)) and elastic_fdtd_simulation(ElasticRun(c_p=c_p, c_s=c_s, dx=dx, duration_s=duration, sources=..., rho=..., ...)): a simulation is one record, with the same arguments, which takes every field by name and checks them all when it is built. duration is duration_s, and the acoustic boundaries= and absorbing_layer_cells= are now one FDTDBoundaries, as the elastic ones are one ElasticBoundaries; compute= stays on the function. A bad argument raises where the run is written, with the same class and the same words, except that a refused duration now names duration_s |
a boundaries= of elastic_fdtd_simulation that is not an ElasticBoundaries, which failed inside the run |
refused with TypeError when the ElasticRun is built |
an ElasticRecording with a malformed probe, an unknown or repeated field or a bad snapshot count, refused only when elastic_fdtd_simulation ran it; a recording= of another type, which failed inside the run |
refused when the record is built, with the same class and the same words, and a probe off the grid still refused by the run; a recording= that is not the run's own record (FDTDRecording for an FDTDRun, ElasticRecording for an ElasticRun) raises TypeError naming it when the run is built |
sidebands= on gear_mesh_frequencies and induction_motor_frequencies, the poles, rotor_bars and slot_harmonics of induction_motor_frequencies, and lobe_orders= on blade_pass_frequencies |
n_sidebands, n_poles, n_rotor_bars, n_slot_harmonics and n_lobe_orders |
years= on hearing.nipts and htlan and on vibration.injury_risk and multiple_shock_assessment, and .years on the ISO 1999 results (NiptsResult and HtlanResult in 3.3.0) and on MultipleShockResult |
exposure_duration_years: a duration names its quantity before its unit |
environment.NoisePhase.hours and hours= on evaluation_period_level; hearing.Task.duration_range and .duration_samples, in hours |
duration_hours; .duration_range_hours and .duration_observations_hours, since a _samples ending reads as a count of samples |
seconds= on room.sweep_signal, inverse_filter and shaped_sweep_signal, on electroacoustics.synchronized_sweep_signal and swept_sine_distortion, on signals.noise_signal and on speech.stipa_signal; duration= on room.image_source_rir, SweptSineDistortionResult.duration, and io.Signal.duration and io.AudioFileInfo.duration (4.0.0rc1); flat_duration=, leading_duration= and trailing_duration= on materials.adrienne_window, StationarityTestResult.segment_duration and PileStrikeResult.pulse_duration |
duration_s, the spelling the other durations in seconds already had, and flat_duration_s=, leading_duration_s=, trailing_duration_s=, .segment_duration_s and .pulse_duration_s: a duration ends in its unit |
hours= on environment.lden and ldn |
period_hours=, which is now keyword-only |
assessment_period_min= on environment.impulse_prominence, and ImpulseProminenceResult.assessment_period_min |
assessment_period_minutes: a trailing _min reads as a minimum (f_min), so the minute is spelled out, as the hour is |
ReportMetadata.source_positions and .receiver_positions |
.n_source_positions and .n_receiver_positions |
signal_in= on loudness_ecma, tonality_ecma, roughness_ecma, fluctuation_strength_ecma and fluctuation_strength; signal= on loudness_moore_glasberg_time, on the distortion and noise measurements of electroacoustics (thd, thd_plus_noise, sinad, weighted_thd, harmonic_analysis, harmonic_distortion, dynamic_range, idle_channel_noise, modulation_distortion, difference_frequency_distortion, total_difference_frequency_distortion, dynamic_intermodulation_distortion), on impulsive_sound_adjustment and sound_pressure_level_history, on the human-vibration functions (running_rms, mtvv, vibration_dose_value, motion_sickness_dose_value, crest_factor, apply_weighting, apply_band_limiting) and on room.plot_excitation |
x |
tone_freq= on tone_to_noise_ratio and prominence_ratio |
tone_frequency=, which, like resolution_hz=, is now keyword-only |
A choice reads the same everywhere it is offered. A band set is the integer
fraction that OctaveFilterBank, decay_curve and sound_intensity already
took, 3 for one-third octaves and 1 for octaves; the words "third",
"third-octave", "one-third-octave" and "octave" are refused, and a table
read by band set is keyed by the same integer. A free, a diffuse and a
pressure field are written "free", "diffuse" and "pressure". A frequency
weighting is chosen by weighting, and leaving the signal unweighted is
written "Z" wherever that is offered: on the sound-level weightings it is the
Z-weighting of IEC 61672-1, and elsewhere it is the response the standard
leaves unweighted, such as the band limitation alone of the DIN 45669-1
vibration meter.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
band= on field_incidence_correction, mass_law_transmission_loss, single_panel_transmission_loss, double_wall_transmission_loss, orthotropic_transmission_loss, short_pulse_mean_square_force, tapping_force_spectrum, covering_improvement, a_weighted_maximum_impact_level and cylindrical_shell_modal_density, and .band on TappingForceResult and AWeightedMaximumImpactResult |
fraction= and .fraction, 3 or 1 |
bands= on weighted_rating, weighted_impact_rating, SoundReductionResult.rating, facade_sound_reduction, normalized_flanking_level_difference, normalized_flanking_impact_level, calculated_sound_reduction_index, reciprocity_impact_level, in_situ_element, detailed_airborne_prediction and detailed_impact_prediction |
fraction=; None still reads the band set from the values where it did |
band_type= on sound_power_intensity, sound_power_intensity_points, position_count_factor and determination_standard_deviation |
fraction= |
bandwidth= on tapping_machine_force_level_estimate |
fraction= |
building.HEAVY_IMPACT_A_WEIGHTING["third"] and ["octave"] |
[3] and [1] |
"free-field" and "diffuse-field" on hearing.reference_threshold, and in hearing.FIELDS |
"free" and "diffuse" |
curve= on filters.weighting_filter and WeightingFilter, WeightingFilter.curve and WeightingComplianceResult.curve |
weighting= and .weighting |
weighted= on broadcast.quasi_peak_meter, and QuasiPeakResult.weighted |
weighting="468" (the default) or weighting="Z", and .weighting |
weighting=None on signals.ln_levels and sel |
weighting="Z", now the default |
building.PathContribution.fraction, the share of the transmitted energy a path carries |
.energy_fraction, so that fraction names only a band set |
building.DetailedAirborneResult.fractions and DetailedImpactResult.fractions, the share of the energy each path carries in each band |
.energy_fractions |
Every public name has one address #
A handful of names could be imported from a second module in 3.3.0 or 4.0.0rc1, or from a module that listed something its package did not publish, and the ANP database put a private name in two constructors. Each name has a single address now, the one the resolver above returns, and none is private:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
vibration.partial_exposure |
vibration.daily_exposure, the function it was a second name for. Called with the value and the duration of one operation, it returns that operation's partial exposure Ai(8), and the number does not move |
the ISO 717 ratings listed by building.measurement.insulation: weighted_rating, weighted_impact_rating, their _extended forms, weighted_impact_improvement, impact_improvement_adaptation_term and the four rating results |
building.weighted_rating and the rest, defined in building.measurement.ratings |
LowFrequencyProcedure listed by building.measurement.insulation |
building.LowFrequencyProcedure, defined in building.measurement.low_frequency |
the ISO 12354-1 Annex D linings listed by building.prediction.resilient_layers: lining_improvement, lining_improvement_in_situ, lining_resonance_frequency, weighted_lining_improvement, LiningImprovementResult |
building.lining_improvement and the rest, defined in building.prediction.linings |
emission.DeclarationForm; Grade and Surface listed by emission.sound_power; EQFilterType listed by filters.equalizer (metrology.equalizer in 3.3.0) |
nothing to import: no type alias is public. Pass the string the parameter takes, form="single-number" for instance, and the API reference shows each parameter's Literal[...] where the alias used to be |
BASIC_METHOD_MAX_CREST_FACTOR listed by vibration.human.exposure |
not published. vibration.crest_factor warns above 9, the crest factor up to which ISO 2631-1 6.2.2 holds the basic method sufficient |
REFERENCE_IMPEDANCE, REFERENCE_AREA and REFERENCE_SOUND_POWER of emission.vibration_sound_power, a module with no __all__ whose package never published them |
not published. The 400 N·s/m³ and the 1 m² are the defaults of reference_impedance= and reference_area= in emission.radiated_sound_power_level, and the 1 pW is metrology.REFERENCE_VALUES["gas"]["sound_power"].value |
AnpAircraft(..., _database=db) and aircraft._database |
ANPAircraft(..., database=db) and aircraft.database, still left out of the repr and of comparisons |
AnpDatabase(..., performance=...) (4.0.0rc1) |
no performance=, whose type nothing published: aircraft.load_anp_database reads the performance tables of an export, and a database built by hand flies fixed-point profiles |
from phonometry import building, vibration
# ISO 5349-2 E.3: the brush-saw's partial exposure, 4,6 m/s² for 2 h
print(round(vibration.daily_exposure(4.6, 2 * 3600.0), 1))
print(callable(building.weighted_rating), callable(building.lining_improvement))
print(hasattr(vibration, "partial_exposure"))
# 2.3
# True True
# False
A function is named for what it returns, once #
A computation is named for the quantity it gives back, and one computation has
one name. A unit stays in a function's name only where that quantity is
written in more than one unit (peak_velocity_from_kb_mm_s,
air_power_attenuation_per_m); a level, a correction, an index or a frequency
carries none, because it only ever comes in decibels or hertz. The
root-sum-square of independent uncertainties is one function,
metrology.combined_standard_uncertainty, whichever standard prints it, and
the coverage probability of an expanded uncertainty is spelled coverage
wherever it is asked for.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
environment.combined_standard_uncertainty(contributions) |
metrology.combined_standard_uncertainty(contributions), the same signature and the same number; a (u, c) pair with a negative u is now refused |
noise_control.combine_stage_levels(80.0, 74.0), noise_control.combine_internal_levels(trim, expander) |
noise_control.combined_stage_level([80.0, 74.0]), noise_control.combined_internal_levels([trim, expander]): the levels come as one sequence, as every other energy sum takes them |
building.energy_average_level(levels, 0), room.directivity_energy_average(levels, 0) |
axis=0, by name |
materials.PUBLISHED_AIR |
materials.ABSORBER_AIR, the dry air at 20 °C the absorber models default to, with the same values. The PUBLISHED_ prefix belongs to the catalogues, and the name no longer credits the air to the Johnson-Champoux-Allard model, whose book prints another |
metrology.combine_uncertainty(model, quantities) |
metrology.uncertainty_propagation(model, quantities), with the same arguments |
metrology.expanded_uncertainty(result, 0.95) |
result.expanded(0.95), the method of the result it took |
environmental.expanded_uncertainty(u, confidence=0.95), the ISO 1996-2 one, which the top level of 3.3.0 published as environmental_expanded_uncertainty |
environment.environmental_expanded_uncertainty(u, coverage=0.95), with the same number: 2.4 dB for a u of 1.2 dB. The top-level expanded_uncertainty of 3.3.0 was another function, the ISO 12999-1 one, which gives 2.352 dB for the same u; the table of gone names says where it went |
coverage_factor(0.95, one_sided) at the top level of 3.3.0 |
building.insulation_coverage_factor(0.95, one_sided=...), the ISO 12999-1 factor it forwarded to. metrology.coverage_factor(coverage, dof) is another function, the GUM factor from Student's t, which gives 1.96 to two decimals for 95 % and infinite degrees of freedom and has no one-sided form |
The 3.3.0 top-level names this renames or removes (combine_uncertainties,
combine_uncertainty, expanded_uncertainty, combine_linings,
combine_subareas, combine_partial_exposures, combine_age_and_noise,
air_attenuation_m, attenuation_from_alpha and
air_attenuation_coefficient) are in the table of the names that are gone,
at the end of this page.
from phonometry import metrology, noise_control
# ISO 1996-2:2017 Table G.2, the five products c_j u_j of one hour by a road
print(round(metrology.combined_standard_uncertainty([0.59, 0.3, 2.0, 0.40, 0.38]), 2))
print(round(noise_control.combined_stage_level([80.0, 80.0]), 2))
# 2.18
# 83.01
A level or a level difference carries no unit suffix #
A level and a level difference are in decibels by definition (a loudness level
is in phon), so a public name whose head noun is one carries no _db, whether
it is a parameter, a field, a property, a method or a constant. The head noun
is the last noun of the name, past the words that qualify it from behind (a
band, a frequency weighting, before or after, max or min): a level, a
loss, an insulation, an isolation, a reduction, a rejection, a difference, an
improvement, a single-value attenuation, a correction, an adjustment, an
index, the spectrum adaptation term of ISO 717, a shift or an excess of the
level the name names (level_shift), or the printed symbol of one of them. A
name whose head noun does not say decibel keeps the suffix: a tolerance, a
margin, an uncertainty, a deviation, a step, a slope or a rate
(tolerance_db, background_margin_db, expanded_uncertainty_db,
slope_db_per_decade, attenuation_db_per_m). A notebook table still shows
a number under such a name in decibels, now read from its head noun, and a
loudness level in phon; a flag, a text, a complex factor or a record under
one shows no unit, and a number the head noun would misread (the reflection
index of EN 1793-5, the A_eta of IEC 60534-8-3) shows its own. Most of the
names this renames are newer than 4.0.0rc1; the ones that shipped are these.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
MicrophoneCharacteristics.sensitivity_level_db, diffuse_field_sensitivity_level_db, directivity_index_db, equivalent_noise_level_db, noise_band_levels_db, max_spl_db and distortion_spl_db; MicrophoneNoise.equivalent_level_db, MicrophoneOverload.spl_db, MicrophoneDirectivity.index_db |
sensitivity_level, diffuse_field_sensitivity_level, directivity_index, equivalent_noise_level, noise_band_levels, max_spl, distortion_spl; equivalent_level, spl, index |
LoudspeakerCharacteristics.sensitivity_level_db, reference_level_db, directivity_index_db and spl_db, spl_db= on loudspeaker_characteristics, LoudspeakerDirectivity.index_db |
sensitivity_level, reference_level, directivity_index, spl, spl=, index |
QuasiPeakResult.level_db; level_db= on stipa_signal and fluctuation_strength_am_noise |
level, level= |
WindowMetricsResult.scalloping_loss_db and worst_case_processing_loss_db, SynchronousAverageResult.noise_reduction_db, ResampledSignalResult.stopband_attenuation_db and stopband_attenuation_db= on resample_signal |
scalloping_loss, worst_case_processing_loss, noise_reduction, stopband_attenuation, stopband_attenuation= |
EmissionPressureResult.level_db, measured_level_db, background_correction_db and local_correction_db, the same three parameters of emission_sound_pressure_level, measured_level_db and background_level_db on background_noise_correction_at_workstation, local_correction_db on grade_from_local_correction, environmental_correction_db and directivity_index_db= on environmental_ratio_from_k2 and environmental_ratio_from_absorption |
level, measured_level, background_correction, local_correction, background_level, environmental_correction, directivity_index= |
noise_control.MODAL_FILTER_ATTENUATION_DB |
MODAL_FILTER_ATTENUATION |
emission.MAX_K3_DB and GRADE_2_MAX_K3_DB, the cap on the local environmental correction $K_3$ and its grade 2 bound |
MAX_K3, GRADE_2_MAX_K3 |
sound_reduction_index_db on environment.airborne_insulation_rating |
sound_reduction_index |
from phonometry import signals
metrics = signals.window_metrics("hann")
print(round(metrics.scalloping_loss, 2), round(metrics.worst_case_processing_loss, 2))
# 1.42 3.18
A name says the quantity it holds #
A name that put _db after words that only qualify it (corrected_db,
floor_db, threshold_db, mean_db) said the unit of a number and never
what the number is. Each now carries the noun of what it holds. A level takes
level or levels and then loses its _db by the rule of the section above
(threshold_level, corrected_levels, emission_levels), a level
difference takes its own noun (floor_level_difference, mean_attenuation,
min_isolation), and any other quantity keeps _db after its noun
(fixture_uncertainty_db, lower_tolerance_db, prominence_limit_db). Most
of these names are newer than 4.0.0rc1; the ones that shipped are these.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
psychoacoustics.ToneAssessment.criterion_db |
prominence_limit_db |
signals.WindowMetricsResult.highest_sidelobe_db |
highest_sidelobe_level |
broadcast.KWeightingResponse.shelf_db and highpass_db |
shelf_magnitude_db and highpass_magnitude_db, beside magnitude_db |
signals.LifterResult.liftered_db |
liftered_spectrum_db, beside spectrum_db |
operating_db= on emission.total_standard_deviation |
sigma_omc_db=, the name every sound power function gives the standard deviation of the operating and mounting conditions |
polar_db of electroacoustics.MicrophoneCharacteristics and electroacoustics.LoudspeakerCharacteristics |
polar_response_db |
from phonometry import emission, signals
print(round(signals.window_metrics("hann").highest_sidelobe_level, 1))
# -31.5
print(emission.total_standard_deviation(1.5, sigma_omc_db=2.0))
# 2.5
A module is never hidden behind a function of its own name #
Twenty-three modules of 4.0.0rc1 shared their name with the function their
package published: signals/correlation.py sat beside signals.correlation().
The package attribute is the function, so import phonometry.signals.correlation as m bound the function,
signals.correlation.time_delay raised AttributeError, and only from phonometry.signals.correlation import time_delay reached the module. Each of
those modules is private now. The function keeps its name, every name the
package published from the module keeps its address, and the only thing gone is
the import through the file path:
| 4.0.0rc1 | 4.0 |
|---|---|
from phonometry.signals.correlation import time_delay |
from phonometry.signals import time_delay |
from phonometry.fluids.air import air |
from phonometry.fluids import air, or fluids.air(...) after from phonometry import fluids |
broadcast.program_loudness, emission.sound_power_anechoic, emission.sound_power_in_duct, emission.sound_power_in_situ, emission.sound_power_intensity, emission.sound_power_intensity_points, emission.sound_power_reverberation, fluids.air, materials.absorbers.airflow_resistance, noise_control.duct_path, psychoacoustics.quality.fluctuation_strength, psychoacoustics.quality.fluctuation_strength_ecma, psychoacoustics.quality.roughness_ecma, psychoacoustics.quality.tonality_ecma, psychoacoustics.quality.tone_audibility, room.crowd_noise, room.impulse_response, signals.cepstrum, signals.correlation, signals.envelope, underwater.propagation.seabed_reflection, vibration.structural.junction_transmission, vibration.structural.radiation_efficiency as module paths |
the package before the last dot, which publishes the function and its companions: from phonometry.room import impulse_response, mls_impulse_response |
the numbers those modules kept for themselves: the gates and block lengths of broadcast.program_loudness (ABSOLUTE_GATE, RELATIVE_GATE, BLOCK_DURATION, BLOCK_OVERLAP, SHORT_TERM_DURATION, MAX_METER_STEP, LRA_RELATIVE_GATE, LRA_PERCENTILES), DEFAULT_SELF_NOISE_FLOOR of noise_control.duct_path, and SIGMA_NARROWBAND_LEVEL and COVERAGE_FACTOR_90 of psychoacoustics.quality.tone_audibility |
not published, as before: their packages never took them up. Each comes from the document its module follows, and the function that reads it applies it or takes it as the default of self_noise_floor=, sigma_level_db= or coverage_factor=. The 0.1 s step is the period of the 10 Hz update rate EBU Tech 3341 requires, and the 0 dB floor is the default of the worked duct-path sheet in Long's Architectural Acoustics |
the prominence thresholds PROMINENT_TONALITY_TU_HMS, PROMINENT_ROUGHNESS_ASPER and PROMINENT_FLUCTUATION_STRENGTH_VACIL of the ECMA-418-2 modules |
not published, and no function applies them: compare the result yourself. ECMA-418-2 clause 6.3 calls a tonality prominent when, for a stationary sound, specific_tonality exceeds 0.4 tu_HMS at a local maximum whose entry in tonal_frequencies lies between the centre frequencies one Bark_HMS below and above, or, for a non-stationary sound, when tonality exceeds 0.4 tu_HMS. Clause 7.2 calls a roughness prominent when roughness exceeds 0.2 asper, and clause 9.2 a fluctuation strength when fluctuation_strength exceeds 0.2 vacil_HMS |
In 3.3.0 several of them lived elsewhere (metrology/correlation.py,
psychoacoustics/tone_audibility.py); the package import is the answer there
too.
signals.test_signals (4.0.0rc1) is private as well, for another reason:
pytest collects a module whose name starts with test_, and the prefix belongs
to test files. Every function it held keeps its signals. address, so from phonometry.signals.test_signals import noise_signal is from phonometry.signals import noise_signal.
The type aliases those modules defined went with them, and no public path
reaches them now: PrecisionSurface, PrecisionArray and PrecisionRoom of
emission.sound_power_anechoic, MicrophoneShield of
emission.sound_power_in_duct, Grade and BandType of
emission.sound_power_intensity, and DeterminationGrade and BandType of
emission.sound_power_intensity_points. Annotate with the Literal each stood
for: Literal["sphere", "hemisphere"] for PrecisionSurface, and so on.
BandType named a band set, which is now the integer fraction:
Literal[1, 3].
from phonometry import room, signals
print(callable(signals.correlation), callable(signals.time_delay))
print(callable(room.impulse_response), callable(room.mls_impulse_response))
# True True
# True True
And every public module says what it publishes #
A module without __all__ says nothing about which of its names are public,
so a constant it defined for its own use looked as public as its functions,
and some of them reached guides and scripts through the full module path. Every
public module now lists what it defines and its package publishes, and anything
else it defines takes a leading underscore. These names were reachable that
way in 3.3.0 or 4.0.0rc1 and are not any more:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
OCTAVE_BANDS, NC_INDICES and NC_CURVES of room.noise_criteria (room.room_noise in 3.3.0) |
room.NC_OCTAVE_BANDS_HZ, room.NC_RATINGS and room.NC_CURVE_LEVELS, published with their unit: the ten bands of ANSI/ASA S12.2 Table 1, its twelve designations and their band levels |
BAND_CENTERS, BAND_IMPORTANCE, REFERENCE_INTERNAL_NOISE and VOCAL_EFFORTS of speech.sii (hearing.sii in 3.3.0) |
speech.sii_procedure("one-third-octave"), whose frequencies, band_importance and internal_noise are the same arrays, and speech.standard_speech_spectra().vocal_efforts |
NIPTS_FREQUENCIES of hearing.noise_induced_hearing_loss |
the frequencies of the hearing.nipts(...) result |
VALIDATED_YEARS, VALIDATED_FRACTILES and VALIDATED_L_EX_MAX of the same module |
not published. nipts and htlan warn outside the 1 to 40 years, the 0.05 to 0.95 fractiles and the 100 dB ISO 1999 validates |
OCTAVE_BANDS of noise_control.hvac and of room.enclosed_space_absorption |
not published: each is the default band axis of its functions, and every result carries its frequencies |
SPEED_OF_SOUND, AIR_ATTENUATION and PUBLISHED_AIR_CONDITION (DEFAULT_AIR_CONDITION in 3.3.0) of room.enclosed_space_absorption |
not published: the 345.6 m/s default of speed_of_sound=, and the six conditions air_condition= takes, which its docstring lists, "20C_50-70" the one clause 4.3 recommends |
REFERENCE_VELOCITY, REFERENCE_FORCE, REFERENCE_SOUND_POWER and FREE_VELOCITY_REFERENCE of building.measurement.structure_borne_power (building.structure_borne_power in 3.3.0), and REFERENCE_PRESSURE of environment.assessment.impulsive_sound (environmental.impulsive_sound in 3.3.0) |
the .value of the metrology.REFERENCE_VALUES entry each was read from, since the entry is a record and not a number: ["solid"]["velocity"].value (1 nm/s), ["solid"]["force"].value (1 µN), ["gas"]["sound_power"].value (1 pW), ["solid"]["velocity_alternative"].value (the 50 nm/s of note b of Table 3, the ISO 9611 free-velocity reference) and ["gas"]["sound_pressure"].value (20 µPa) |
REFERENCE_MOBILITY and CHARACTERISTIC_PLATE_MOBILITY of building.measurement.structure_borne_power (building.structure_borne_power in 3.3.0), and REFERENCE_PLATE_MOBILITY of building.prediction.installed_structure_borne (building.installed_structure_borne in 3.3.0) |
not published. REFERENCE_MOBILITY is the 1 m/(N s) reference mobility of EN 15657 clause 5, which the functions apply in its Formulae (15), (17) and (18); the plate mobility is the default of characteristic_mobility= and plate_mobility= |
SPEED_OF_SOUND, AIR_DENSITY, REFERENCE_FREQUENCY, REFERENCE_LENGTH and MAX_RADIATION_FACTOR of building.prediction.detailed_model |
not published. The air is building.EN12354_AIR, which carries the 340 m/s and the 1.29 kg/m³ |
the coefficients, limits and defaults of environment.assessment.impulsive_sound (environmental.impulse_prominence and environmental.impulsive_sound in 3.3.0): PROMINENCE_COEFFS, ADJUSTMENT_SLOPE, ADJUSTMENT_THRESHOLD, ONSET_RATE_LIMIT, DEFAULT_ASSESSMENT_PERIOD_MIN, ONSET_GRADIENT_LIMIT, TIME_WEIGHTING_F_TAU, MERGE_GAP, SAMPLE_INTERVAL_RANGE, DEFAULT_SAMPLE_INTERVAL, HIGHLY_IMPULSIVE_LIMIT |
not published: each is applied by impulse_prominence or impulsive_sound_adjustment, and the two defaults are those of dt= (20 ms) and assessment_period_minutes= (30 min) |
the Annex C constants of vibration.human.multiple_shock (vibration.multiple_shock_vibration in 3.3.0): MZ_MALE, MZ_FEMALE, DOSE_AMPLITUDE_FACTOR, DOSE_EXPONENT, GRAVITY, ULTIMATE_STRENGTH_INTERCEPT, STRENGTH_AGE_SLOPE_MALE, STRENGTH_AGE_SLOPE_FEMALE, WEIBULL_MALE, WEIBULL_FEMALE, RISK_THRESHOLDS_MALE, RISK_THRESHOLDS_FEMALE |
not published: the functions take sex= and apply the pair it names. compression_dose(..., mz=) defaults to 0.029, the male value of Formula C.2; pass 0.025 for the female one |
DEFAULT_HEADWIND_KT and APPROACH_WEIGHT_FRACTION of aircraft.flight_performance |
not published: the 8 kt default of Aerodrome(headwind_kt=), and the 0.9 of the maximum landing weight the approach is flown at |
STANDARD_ATMOSPHERIC_PRESSURE of materials.resilient.dynamic_stiffness (materials.dynamic_stiffness in 3.3.0) |
not published: the 0.1 MPa default of static_pressure_pa= |
REFERENCE_SPACING of emission.intensity_compliance |
not published: the 25 mm nominal microphone separation of IEC 61043 Table 2, the default of spacing_m= of residual_index_limits and verify_intensity_class |
DISTRIBUTIONS of metrology.uncertainty |
not published: metrology.Quantity refuses a distribution= outside "gaussian", "rectangular", "triangular" and "u-shaped" and names the four |
CIRCULAR_EIGENVALUES, PLANE_WAVE_EIGENVALUE and warn_above_plane_wave_limit of noise_control.duct_modes |
noise_control.circular_duct_cut_on and noise_control.plane_wave_limit; the silencer and duct-path results raise PlaneWaveWarning above the limit themselves |
WALL_ORDER of room.image_source |
not published: a per-wall absorption= is in the order x0, xL, y0, yL, z0, zL |
MAX_ENUMERATED_LATTICE of room.modes, SAMPLE_RATE of speech.objective_intelligibility (hearing.objective_intelligibility in 3.3.0) |
not published: a lattice limit room_modes states when it refuses, and the 10 kHz speech.stoi resamples to |
AUDIBILITY_THRESHOLD_SONE_HMS of psychoacoustics.loudness.ecma (psychoacoustics.loudness_ecma in 3.3.0) |
not published, and no function applies it: ECMA-418-2 clause 5.1.9 calls a signal audible when its total basis loudness exceeds 0.01 sone_HMS |
J1_FIRST_ZERO of electroacoustics.piston |
gone: nothing read it. It is scipy.special.jn_zeros(1, 1)[0] |
critical_bandwidth of environment.sources.wind_turbine (environmental.wind_turbine_noise in 3.3.0) |
the critical_bandwidth of the WindTurbineTonalityResult. environment.critical_bandwidth is another band, the ISO 1996-2 one |
reference_sound of psychoacoustics.quality.sharpness (psychoacoustics.sharpness in 3.3.0) |
not published: the library builds the DIN 45692 clause 6 test signal only to fix its own normalization. It is noise band-limited to 920 to 1080 Hz at 60 dB: pass signals.noise_signal(fs, duration_s) through a 920 to 1080 Hz band-pass and scale it to 0.02 Pa rms, and psychoacoustics.sharpness_din gives it 1.00 acum |
check_guidance of underwater.bioacoustics.weighting |
not published. The functions that take guidance= refuse an unknown one, and underwater.WEIGHTING_GUIDANCE names the known ones |
The type aliases these modules define (NCMethod, EventMetric and the rest)
are not listed either, by the rule above, and stay importable as annotations.
from phonometry import hearing, room, speech
print(room.NC_CURVE_LEVELS[room.NC_RATINGS == 40][0][:3])
print(round(speech.sii_procedure("one-third-octave").band_importance.sum(), 6))
print(hearing.nipts(95.0, 40.0, 0.9).frequencies[:3])
# [84. 74. 64.]
# 1.0
# [ 500. 1000. 2000.]
Every .plot() takes the axes first #
Every result's .plot() now reads plot(ax=None, *, ...): the axes first,
and every other argument by name, language included. Three did not start
with the axes in 3.3.0, so plot(ax) on them handed the axes to the wrong
parameter:
| 3.3.0 | 4.0 |
|---|---|
LoudspeakerCharacteristics.plot("impedance", ax) |
.plot(ax, quantity="impedance") |
MicrophoneCharacteristics.plot("noise", ax) |
.plot(ax, quantity="noise") |
TransferMatrix.plot(f, rho_c, ax) |
.plot(ax, frequencies=f, characteristic_impedance=rho_c) |
Six results that are newer than 3.3.0 took language by position in
4.0.0rc1: the four hearing-protector ratings and the two low-frequency
intensity results. plot(ax, "es") on those is plot(ax, language="es")
now, as it is everywhere else.
The public plot_* helpers, which draw a device or a geometry rather than a
result, share one shape now as well: what they draw by position, and the
axes, the language and the style keywords by name,
plot_x(<data>, *, ax=None, ..., language="en", **kwargs). Seventeen took the
axes after their data and six took them first. plot_silencer_geometry also
took every dimension as a keyword of its own; it takes the kind and the
geometry a ReactiveSilencerResult keeps now, the dimensions in one mapping
under the same keys, so the drawing reads like the result:
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
vibration.plot_plate_geometry(0.8, 0.6, ax), environment.plot_barrier_geometry(ax, source_height=...) and the other twenty-one public plot_* helpers |
plot_plate_geometry(0.8, 0.6, ax=ax), plot_barrier_geometry(ax=ax, source_height_m=...) |
noise_control.plot_silencer_geometry("expansion chamber", ax, length=0.3, chamber_area=0.04, pipe_area=0.01) |
plot_silencer_geometry("expansion chamber", {"length": 0.3, "chamber_area": 0.04, "pipe_area": 0.01}, ax=ax) |
Verdicts are result objects, not dictionaries #
The three verify_* functions of 3.3.0 returned dict[str, Any] and now
return a frozen dataclass, like every other result in the library.
filter_class_compliance, the public wrapper that existed only to package the
filter verdict, went with the change, since the verifier now returns the
object itself. Each key of the dictionary is an attribute of the same name,
but for passed, which is passes, and every argument after the one the call
is about is written by name.
| 3.3.0 | 4.0 |
|---|---|
verify_filter_class(bank)["overall_class"] |
filters.verify_filter_class(bank).overall_class |
verify_filter_class(bank, 4096) |
filters.verify_filter_class(bank, n_points=4096) |
verify_weighting_class(wf)["overall_class"] |
filters.verify_weighting_class(wf).overall_class |
verify_aircraft_noise_system(...)["passed"] |
aircraft.verify_aircraft_noise_system(...).passes |
filter_class_compliance(bank) |
filters.verify_filter_class(bank), which returns the same FilterComplianceResult |
verify_intensity_class and verify_quasi_peak_dynamics are newer than
3.3.0, and in 4.0.0rc1 they already returned their records.
from phonometry.filters import OctaveFilterBank, verify_filter_class
verdict = verify_filter_class(OctaveFilterBank(48000, fraction=1, limits=[125, 4000]))
print(verdict.overall_class, len(verdict.bands))
verify_running_rms_decay is newer than 3.3.0, and in 4.0.0rc1 it returned a
bare bool, which threw away the printed interval and the measured time it
had judged. It now returns a RunningRMSDecayVerification that keeps both:
the verdict is .passes, beside .measured_time_s, .printed_time_s,
.tolerance_s and the interval as .lower_time_s and .upper_time_s. The
object refuses to be read as a truth value, so an
if verify_running_rms_decay(...): written against the release candidate
raises TypeError instead of passing every meter.
A verdict says passes, refuses a truth value, and comes from a verb #
A judgement is named for what it judges: verify_ an instrument, assess_ a
measured situation, check_ the setup a method needs. Each returns a record
that keeps its reasons, and a pass or a fail is spelled passes on every one of
them. A record a judging function returns, and every record with a passes,
refuses to be read as a truth value: if verdict: raises TypeError and the
message names what to read. In 3.3.0 and 4.0.0rc1 these records were always
true, so an if written against them passed every failure: read .passes on
QuasiPeakDynamicsResult, AircraftSystemComplianceResult,
WeightingVerification, PhaseVerification, SignalBurstVerification,
DBHRCheck, DBHRAssessment, ActivityAssessment and PeriodAssessment;
.overall_class on FilterComplianceResult, WeightingComplianceResult and
IntensityInstrumentComplianceResult; .within_guideline on
DamageAssessment, since exceeding a guideline value of DIN 4150-3 is not a
failure; .qualified on PrecisionCriteria; .adjustment on
TonalAssessmentResult; and .decisive_audibility or .audible on
ToneAudibilityResult.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
.complies on DbHrCheck, DbHrAssessment (now DBHRCheck, DBHRAssessment), ActivityAssessment and PeriodAssessment |
.passes |
vibration.is_significant_change(change, zone_b_upper) |
vibration.assess_operational_change(change, zone_b_upper).significant, beside the .threshold it is read against. A significant change is a reason to investigate, not a failure, so the flag keeps its name |
materials.limp_frame_applicable(k_c, criterion=...) |
materials.check_limp_frame(k_c, criterion=...).passes, beside the .ratio and the .threshold. A ratio exactly on the threshold no longer passes: Allard & Atalla print both criteria as strict inequalities |
fi.field_is_stationary(limit=...) on a FieldIndicators |
fi.check_field_stationarity().passes, and band by band its .stationary. The limit is the 0.6 of Table B.3, read as .limit, and no longer an argument |
room.perceptibly_different(symbol, first, second) |
room.assess_perceptible_difference(symbol, first, second).different; the two values must now have the same shape |
materials.check_base_plate_scattering(s) == () |
materials.check_base_plate_scattering(s).passes, with the bands over the limit in .exceeded_frequencies and the per-band .margins, .exceeds and .limits beside them. A coefficient that is not finite raises ValueError, where it used to pass |
corrected, limited = building.background_corrected_level(lp, lb) |
result = building.background_corrected_level(lp, lb), then result.corrected_levels and result.limited |
k1, held = emission.background_noise_correction_at_workstation(lp, lb) |
result = emission.background_noise_correction_at_workstation(lp, lb), then result.correction and result.upper_bound |
The 3.3.0 top-level names this renames (rigid_mass_calibration_check,
satisfies_lower_requirement, satisfies_upper_requirement,
strong_coupling_satisfied and tonal_seeking_survey) are in the table of
the names that are gone, at the end of this page.
from phonometry import building, materials
conformity = building.assess_requirement_conformity(52.0, 1.5, 50.0, bound="minimum")
print(conformity.passes, conformity.margin_db)
# True 0.5
check = materials.check_base_plate_scattering([0.02] * len(materials.BASE_PLATE_BANDS_HZ))
print(check.passes, check.exceeded_frequencies.size)
# True 0
try:
bool(check)
except TypeError as error:
print(type(error).__name__)
# TypeError
The filter bank returns a result, not a tuple #
octave_filter() and OctaveFilterBank.filter() returned two items normally
and three when sigbands=True asked for the band waveforms. The length of the
answer depended on a keyword, which is why the pair needed twelve @overload
declarations to be typed at all, and why _, _, bands = bank.filter(...) was
a line you had to count commas in.
They now return an OctaveFilterResult with named fields. The other answers
of the bank that were tuples are records too: the spectrogram is an
OctaveSpectrogramResult, and the band set the bank is designed on is read
from attributes spelled out in full.
| 3.3.0 | 4.0 |
|---|---|
spl, freq = octave_filter(x, fs) |
r = octave_filter(x, fs), then r.levels and r.frequencies |
spl, _ = octave_filter(x, fs) |
octave_filter(x, fs).levels |
_, freq = octave_filter(x, fs) |
octave_filter(x, fs).frequencies |
_, _, bands = bank.filter(x, sigbands=True) |
bank.filter(x, sigbands=True).require_bands() |
levels, freq, times = bank.spectrogram(x) |
r = bank.spectrogram(x), then r.levels, r.frequencies and r.times (an OctaveSpectrogramResult, drawn with r.plot()) |
bank.freq, bank.freq_d, bank.freq_u, bank.nominal_freq, bank.num_bands |
bank.frequencies, bank.lower_edges, bank.upper_edges, bank.labels, bank.n_bands, read-only: the arrays refuse writes and labels is a tuple |
import numpy as np
from phonometry import filters
result = filters.octave_filter(np.zeros(8000) + 1e-6, 8000, fraction=3)
print(len(result.frequencies), result.bands)
# 25 None
bands is None unless the call asked for sigbands=True, and levels is
None for a call made with calculate_level=False. Code that needs either
one can say so with require_bands() or require_levels(), which return the
value or raise naming the argument that was missing, rather than handing back
a None that fails several lines later.
The result also draws itself, so the band spectrum is one call:
ax = result.plot()
Other answers that were tuples are records #
Every other answer that came back as a tuple of different quantities, to be
unpacked by position, is a record with named fields now, and none of them
unpacks: a line that still does raises TypeError: cannot unpack non-iterable ... instead of handing back the wrong column. A tuple is left
only where its items are alike, such as the two ends of a range, lower
first.
| 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|
freq, lower, upper, labels = filters.nominal_frequencies(3) |
b = filters.nominal_frequencies(3), then b.frequencies, b.lower_edges, b.upper_edges and b.labels (a FractionalOctaveBands) |
epnl, pnltm, kf, kl = aircraft.epnl_from_pnlt(pnlt) |
r = aircraft.epnl_from_pnlt(pnlt), then r.epnl, r.pnltm, r.band_limits (the pair (kF, kL)), r.bandsharing_adjustment and r.duration_correction (an EPNLIntegration) |
freqs, delta_l = building.improvement_octave_bands(dl, f) |
s = building.improvement_octave_bands(dl, frequencies=f), then s.frequencies and s.values (an OctaveBandSpectrum, whose quantity says what the values are) |
freqs, values = result.octave_bands() on a building.FloorCoveringImprovementResult |
result.octave_bands().frequencies and .values, the same OctaveBandSpectrum |
l_in, s_m = building.combine_subareas(l_in, areas) |
r = building.subarea_intensity_level(l_in, areas), then r.levels and r.measurement_area (a SubareaIntensityLevel) |
freqs, u = band_uncertainty.to_arrays() on a building.BandUncertainty |
band_uncertainty.frequencies and band_uncertainty.uncertainties, the fields it was read from |
bx, bz, bxz = building.corrugated_plate_stiffness(...) |
b = building.corrugated_plate_stiffness(...), then b.b_x_n_m, b.b_z_n_m and b.b_xz_n_m (a CorrugatedPlateStiffness) |
f, lower, upper = building.heavy_impact_source_limits(source) |
lim = building.heavy_impact_source_limits(source), then lim.frequencies, lim.lower and lim.upper (a HeavyImpactSourceLimits) |
width, k = building.wall_tie_stiffness(tie), building.WALL_TIE_STIFFNESS[tie][1] |
t = building.wall_tie_stiffness(tie), then t.cavity_width_m and t.stiffness (a WallTieStiffness, which is also what each row of WALL_TIE_STIFFNESS holds) |
result.ratings on a building.LiningImprovementResult |
result.delta_rw, result.delta_ra and result.delta_ratr, the fields the tuple was read from |
f, gamma2 = electroacoustics.coherence(x, y, fs) |
c = electroacoustics.coherence(x, y, fs), then c.frequencies and c.coherence (a CoherenceResult, with .plot()) |
f, levels = emission.octave_band_levels(levels, f) |
o = emission.octave_band_levels(levels, frequencies=f), then o.frequencies and o.levels (an OctaveBandLevels, with .plot()) |
f, class_1, class_2 = emission.residual_index_limits(device) |
lim = emission.residual_index_limits(device), then lim.frequencies, lim.class_1 and lim.class_2 (a ResidualIndexLimits) |
wavelengths, levels = environment.wheel_roughness(brake), and the same of rail_roughness, contact_filter and impact_roughness_single |
w = environment.wheel_roughness(brake), then w.wavelengths_mm and w.levels (a WavelengthSpectrum, with .plot()) |
source_a, source_b = environment.traction_sound_power(vehicle), and the same of aerodynamic_sound_power |
p = environment.traction_sound_power(vehicle), then p.source_a and p.source_b (a RailSourceSpectra) |
RollingStock(wheel_roughness=(wavelengths, levels), traction=(a, b), ...), RailwayTrack(rail_roughness=(wavelengths, levels), ...) |
the same fields given a WavelengthSpectrum(wavelengths_mm=..., levels=...) or a RailSourceSpectra(source_a=..., source_b=...); a bare pair raises TypeError naming the field |
f, lower, upper = filters.weighting_class_limits(1) |
lim = filters.weighting_class_limits(1), then lim.frequencies, lim.lower and lim.upper (a WeightingClassLimits) |
rho, kappa = materials.slit_effective_properties(f, ...), and the same of rectangular_duct_properties |
p = materials.slit_effective_properties(f, ...), then p.effective_density and p.bulk_modulus (an EffectiveFluidProperties) |
fc, alpha = materials.one_third_octave_absorption(alpha, f) |
b = materials.one_third_octave_absorption(alpha, frequencies=f), then b.frequencies and b.absorption (a OneThirdOctaveAbsorption, with .plot()) |
a, b, c, d = materials.wave_decomposition(...), p0, pd, u0, ud = materials.face_quantities(...) |
w = materials.wave_decomposition(...) with w.a to w.d (a WaveAmplitudes), q = materials.face_quantities(...) with q.p0, q.pd, q.u0 and q.ud (a FaceQuantities) |
k, U = result.expanded(0.95) on a metrology.UncertaintyResult |
e = result.expanded(0.95), then e.coverage_factor and e.expanded_uncertainty (an ExpandedUncertainty) |
f, spl = psychoacoustics.equal_loudness_contour(40.0), f, tf = psychoacoustics.hearing_threshold() |
c = psychoacoustics.equal_loudness_contour(40.0), then c.frequencies, c.levels and c.phon, which is None for the threshold (a LoudnessContour, with .plot()) |
f, v = vibration.foundation_guideline_curve(building_class) |
g = vibration.foundation_guideline_curve(building_class), then g.frequencies and g.velocities_mm_s (a GuidelineCurve) |
chi, psi = vibration.junction_wave_parameters(...) |
w = vibration.junction_wave_parameters(...), then w.chi and w.psi (a JunctionWaveParameters) |
time, level = room.decay_curve(ir, fs), which still unpacked |
curve = room.decay_curve(ir, fs), then curve.times and curve.levels (a DecayCurve, which no longer unpacks) |
times, levels = environment.sound_pressure_level_history(x, fs) |
h = environment.sound_pressure_level_history(x, fs), then h.times and h.levels (a LevelHistory, which no longer unpacks) |
import numpy as np
from phonometry import aircraft, filters
bands = filters.nominal_frequencies(1, [125, 1000])
print(bands.labels)
# ('125', '250', '500', '1k')
epnl = aircraft.epnl_from_pnlt(np.array([90.0, 95.0, 90.0]), 0.5)
print(epnl.band_limits, round(epnl.duration_correction, 2))
# (0, 2) -10.88
The octave spectrum draws itself with .plot(), labelled by its quantity.
Tolerance limits come lower first, and signed #
vibration.weighting_tolerance_percent returned the Table 5 band of
ISO 8041-1 as (upper, lower), and the three constants
CENTRAL_TOLERANCE_PERCENT, SKIRT_TOLERANCE_PERCENT and
TAIL_TOLERANCE_PERCENT held (upper %, lower %, phase °). Every other pair of
limits in the library is (lower, upper), so these two now are too. The lower
limit stays negative, as the table prints it, and -100.0 still means that
the standard sets no lower limit.
This one changes no name and raises nothing: upper, lower = ... still
unpacks two arrays, and swaps them. Read every unpacking of the four:
| 4.0.0rc1 | 4.0 |
|---|---|
upper, lower = vibration.weighting_tolerance_percent(name, f) |
lower, upper = vibration.weighting_tolerance_percent(name, f) |
vibration.CENTRAL_TOLERANCE_PERCENT == (12.0, -11.0, 6.0) |
(-11.0, 12.0, 6.0) |
vibration.SKIRT_TOLERANCE_PERCENT == (26.0, -21.0, 12.0) |
(-21.0, 26.0, 12.0) |
vibration.TAIL_TOLERANCE_PERCENT == (26.0, -100.0, inf) |
(-100.0, 26.0, inf) |
from phonometry import vibration
lower, upper = vibration.weighting_tolerance_percent("Wk", [16.0])
print(lower, upper)
# [-11.] [12.]
A record's fields are required #
Several records carried fields that defaulted to None, so that a result
built by hand from a few of its numbers would still construct. Every reader
then had to ask whether the field was there: the fiche refused a bare rating
only once a report was asked for, and a plot of the geometry raised that the
result "does not retain its geometry". The fields are required now, and a
record built without one, or with None for one (dataclasses.replace
included), raises TypeError naming it.
| Record | Required now |
|---|---|
building.AirborneInsulationResult |
l1, l2, t2, t0 |
building.ImpactInsulationResult |
li, t2, t0 |
building.WeightedRatingResult, building.ImpactRatingResult |
frequencies, measured, shifted_reference |
building.ExtendedWeightedRatingResult, building.ExtendedImpactRatingResult |
frequencies, measured |
building.ApertureTransmissionResult |
depth, now the fourth field; and width_m for a slit or radius for a circular aperture |
building.FacadePredictionResult |
elements, now the sixth field |
emission.IntensityResult |
spacing_m, keyword-only |
environment.BarrierInsertionLoss |
source_height_m, barrier_distance, barrier_height_m, receiver_distance, receiver_height_m, keyword-only |
psychoacoustics.ZwickerLoudness |
field ("free" or "diffuse"), now the fourth field, before n5 |
room.OpenPlanResult |
positions_m, the distances the metrics were fitted on |
materials.LayeredAbsorberResult |
layers, the stack the prediction was solved for |
materials.DiffuserPolarResponse |
well_width and n_repetitions, keyword-only; depths stays optional, because a response predicted from an explicit reflection has none |
materials.MetadiffuserResult |
wells, depth_m and period_m, the panel the reflection was solved for, keyword-only |
materials.SlitResonatorAbsorberResult |
resonators, slit_height_m, lattice_step_m and period_m, the panel the prediction was solved for, keyword-only |
materials.ImpedanceTubeResult |
spacing_m and x1, the microphone spacing and the distance from the sample to the farther microphone, which the reduction cannot run without, keyword-only; diameter_m stays optional, because it need not be supplied |
materials.InSituAbsorptionResult |
source_height_m and microphone_height_m, the set-up the absorption was measured with, keyword-only |
vibration.JunctionTransmissionResult |
thickness1_m and thickness2_m, the plates of the junction, keyword-only |
noise_control.ReactiveSilencerResult |
plane_wave_limit, and exactly one of geometry (a named device) and chain (a SilencerChain); resonances, geometry, plane_wave_limit and chain are keyword-only |
simulation.FDTDResult and simulation.ElasticFDTDResult take two more
fields, after the others: snapshot_decimation, every how many cells a
snapshot keeps along each axis (1 for every cell, as before), and
provenance, the simulation.RunProvenance of where the run stepped. A
result built by hand passes both, and leaving one out raises TypeError
naming it; the results the simulation functions return carry both already.
filters.WeightingFilter(..., high_accuracy=None) used to select the
default. high_accuracy is a plain bool now, True by default, and None
raises TypeError rather than being read as false, which would pick the plain
design.
building.CeilingAttenuationResult.rounded was a field the caller passed in.
It is read from measured now, rounded to the nearest integer as ASTM E413
clause 5.2 asks (the clause leaves a half open, and the library rounds
it up), so it cannot disagree with the data;
leave it out when building the record by hand.
Waveforms inside results come back as the Signal they came from #
A transform handed a Signal has returned a Signal since the contract was
written, but five result objects still stored their waveform as a bare array
next to a loose fs. They now keep the type the input arrived as:
| Field | Is a Signal when the input was one |
|---|---|
envelope(...).signal |
at the input's rate |
time_synchronous_average(...).period_waveform |
at the input's rate |
resample_signal(...).signal |
at fs_new, which then has to be a whole number of hertz |
align_impulse_responses(...).aligned, .reference |
each one if its own input was |
underwater.pile_strike_metrics(...).pressure |
at the input's rate |
A bare array in still gives a bare array out, so code that passes arrays does
not notice. Code that passes a Signal and does arithmetic on one of these
fields goes through np.asarray, as it does for any Signal, and a
calibrated input comes back with calibration_factor=1.0, so the field feeds
the next function in pascals without the factor being applied again.
A block stream yields Signal blocks #
io.read_blocks is newer than 3.3.0, and in 4.0.0rc1 it yielded bare float64
arrays. It now yields a Signal per block, carrying the rate, the
calibration, the channel labels and the provenance io.read gives, and it
takes the same calibration_factor= and reads the same sidecar. Two things
change for a loop written against the release candidate. A block from a
calibrated file reaches the filters and the level functions in pascals, so a
calibration_factor applied by hand on top of it counts twice. And
arithmetic on a block, or on what a filter returns for one, goes through
np.asarray, as it does for any Signal.
Published tables refuse writes #
Every table the library publishes at module level is read-only in 4.0. In
3.3.0 published tables were plain dictionaries and published arrays took
in-place arithmetic, so a line such as REFERENCE_CURVE[500] = 0.9 or
BAND_IMPORTANCE *= 2 changed the number for every caller that ran after it
in the same process, and nothing raised. The dictionaries are now
types.MappingProxyType, including the ones nested inside another table, and
the arrays have their writeable flag cleared. Reading is unchanged; writing
raises TypeError on a table and ValueError on an array.
Code that adjusted a published table has to copy it first:
from phonometry import room
from phonometry.materials.absorbers import REFERENCE_CURVE
curve = dict(REFERENCE_CURVE)
curve[4000] = 1.0
curves = room.NC_CURVE_LEVELS.copy()
curves[0, 0] = 0.0
print(REFERENCE_CURVE[4000], curve[4000], curves[0, 0], room.NC_CURVE_LEVELS[0, 0])
# 0.9 1.0 0.0 78.0
A table with tables inside it needs each level copied, as in
{area: dict(rows) for area, rows in GUIDE_VALUES.items()}. The same copy is
needed before a table is pickled, deep-copied or written out as JSON, because
a read-only mapping supports none of the three.
A result keeps its own copy of the arrays it was given #
In 3.3.0 and in 4.0.0rc1 a result kept the very array it was handed whenever
that array was already of the type the function reads, float64 for levels
and frequencies, because np.asarray hands its argument back unchanged in
that case. Changing the caller's array afterwards, levels[0] = 0.0 or
frequencies *= 2, changed a result already computed and perhaps already
printed. In 4.0 every array that a function or a method of the library
keeps from the arguments it was given is a copy of its own, made read-only
like the published tables, and the caller's array is left as it was. That
holds for the objects that keep arrays to hand out later as well: the
frequency grid of a noise_control.SilencerChain, the axes and flight paths
an aircraft.ANPDatabase is built from, and the medium maps of
simulation.FDTD2D and simulation.ElasticFDTD2D, whose c, rho, c_p
and c_s now stay the ones the time step was computed from. The maps the
engines derive from them, FDTD2D.kappa and ElasticFDTD2D.mu and .lam,
are read-only NumPy copies too: in 4.0.0rc1 an edit to one reached part of the
step and not the time step, and now it raises ValueError, so a different
medium is a new engine built from edited maps. A Signal
keeps a copy of its own samples too, which stays writeable for processing in
place, as the samples of a file read with io.read always were. A result
record built by hand, by calling its class directly, makes the same copy:
every public record that can hold an array copies the arrays it is handed
when it is built, whoever builds it, also inside a tuple, a list or any
mapping. A record held inside another one is kept whole and answers for its
own arrays, and a Signal is no exception: the seven results that hand a
waveform back as a Signal (filters.OctaveFilterResult,
signals.EnvelopeResult, signals.ResampledSignalResult,
signals.AlignedImpulseResponseResult, signals.SynchronousAverageResult,
environment.DirectSoundSubtraction and underwater.PileStrikeResult) hold
one of their own when the library builds them, whose samples stay writeable
like any Signal's, and hold the caller's own when built by hand around it.
Every other array a result holds refuses in-place writes, the ones it
computed as well as the ones it was given, where in 3.3.0 most computed
arrays took them. Writing into one now raises ValueError, so code that
edited one in place has to copy it first:
import numpy as np
from phonometry import io, room
levels = np.array([60.0, 58.0, 55.0, 52.0, 50.0, 48.0, 45.0, 42.0, 40.0, 38.0])
nc = room.noise_criterion(levels)
levels[0] = 0.0
samples = np.zeros(4)
signal = io.Signal(samples, fs=48_000)
samples[0] = 1.0
measured = np.array([1.0, 0.5, 0.25, 0.125])
response = room.ImpulseResponseResult(ir=measured, fs=48_000, method="farina")
measured[0] = 0.0
edited = nc.levels.copy()
edited[0] = 62.0
print(nc.levels[0], nc.levels.flags.writeable, response.ir[0], response.ir.flags.writeable)
print(signal.data[0, 0], signal.data.flags.writeable)
# 60.0 False 1.0 False
# 0.0 True
A catalogue row says what its source claims for each cell #
The published catalogues of materials are new in 4.0: neither 3.3.0 nor
4.0.0rc1 had them. They changed shape once on the way to the final release,
and code written against the main branch in between needs the changes below.
Every row of every catalogue now shares one base, io.CatalogueRow (with
io.BandedRow for a row that prints one value per band), and the same three
questions have the same answer on any of them.
| Before | 4.0 |
|---|---|
SolidMaterial.estimated, OrthotropicWood.estimated |
row.basis, which maps each footnoted field to "estimated" |
SolidMaterial.is_estimate(field), OrthotropicWood.is_estimated(field) |
row.basis_of(field) == "estimated" |
row.is_derived(field) on a value the page gives in a unit the row does not hold (the °F and psi of Ver & Beranek Table 14.1, the sabins of Long Table 7.1) |
field in row.converted; row.converted[field] is the page's figure and its unit, such as ("3e5", "psi") |
row.is_derived(field) on a value the page gives by reference to another of its rows: a cell left blank under a block (Ver & Beranek Table 8.7, ASHRAE Table 30) or a description that reads "Parecido al anterior" (Harris Chapter 32) |
field in row.carried; row.carried[field] names the row |
OrthotropicWood(...) and PlateauMaterial(...) with their own fields by position |
every field by name, as on every other row |
from phonometry._internal.catalogue import CatalogueRow |
from phonometry.io import CatalogueRow |
is_derived now answers only for what the library computes and could compute
again from the row's own cells, such as a bar speed worked out from a modulus
and a density. A value the page gives in another unit is still the page's
number, and so is one it gives by reference to another of its rows, so neither
is derived any more. basis_of answers with the field's own entry, else the
row's, else an empty string, which means the source does not say how the
number was obtained; the five things a source can claim are in
io.CATALOGUE_BASES.
from phonometry import solids
board = solids.PUBLISHED_SOLIDS["hopkins-2007-table-a2/plasterboard_natural_gypsum"]
ear = solids.damping_named("EAR C-1002")[0]
print(board.basis_of("poisson_ratio"))
# estimated
print(ear.converted["youngs_modulus_max_pa"], ear.is_derived("youngs_modulus_max_pa"))
# ('3e5', 'psi') False
The resilient layers became catalogue rows in the same change. A
ResilientLayer is an io.CatalogueRow like every other row, keyed and
credited the way the others are:
| Before | 4.0 |
|---|---|
PUBLISHED_RESILIENT_LAYERS["mineral_wool_rock_60_30"], resilient_layer("mineral_wool_rock_60_30") |
"hopkins-2007-table-a3/mineral_wool_rock_60_30", the "<table>/<row>" key of every catalogue |
layer.attributed_to, a string |
layer.attributed_to["row"], a mapping as on every row |
ResilientLayer(...) with the stiffness, the density and the thickness required |
every quantity optional, and apparent_dynamic_stiffness_n_m3 beside dynamic_stiffness_n_m3 for a source that gives only the apparent $s'_\mathrm{t}$ |
layer.natural_frequency(mass_per_area=...) |
layer.natural_frequency(mass_per_area_kg_m2=...); a layer that holds only $s'_\mathrm{t}$ also takes airflow_resistivity_pa_s_m2= and gas_stiffness_n_m3=, and raises ValueError without the first |
Hopkins Table A3 prints $s'$, the stiffness of the installed layer as the
book's own list of symbols defines it, so its fifteen rows still hold
dynamic_stiffness_n_m3 and return the natural frequencies they returned
before. Four of them hold a density the page prints once for their block and
leaves blank on their own line, and layer.carried["density_kg_m3"] now
names the row that prints it; the density is the same.
from phonometry import materials
rebond = materials.resilient_layer("hopkins-2007-table-a3/rebond_foam_64_20")
print(rebond.attributed_to["row"], round(rebond.natural_frequency(mass_per_area_kg_m2=120.0), 1))
# Hopkins and Hall (2006) 43.6
A catalogue row checks itself when it is built #
Every catalogue row is checked in its constructor, whether the library builds
it from a packaged table or a caller builds it by hand, and a cell nothing
downstream could read raises io.CatalogueError, naming the row and the
field. Code written against the main branch in between that relied on any of
these being accepted has to change:
| Accepted before | 4.0 |
|---|---|
NaN, an infinity, True or a text such as "0,97" in a numeric field |
CatalogueError; a cell the page leaves empty is None |
a fraction in a whole-number field (year), 1 in a flag field (has_section_drawing), a number in a text field |
CatalogueError |
an empty name or source, or a hedge whose text is empty, as in misprinted={"porosity": ""} |
CatalogueError; why_missing answered "" for that cell, which hid the hedge |
a hedge keyed by a field the class does not have, as in ranges={"no_such_field": ...}, or a hedge on a number (ranges, approximate, unquantified, ...) keyed by a text field |
CatalogueError, naming the hedge and the key |
bounded_above or bounded_below on a field with no range; a range, or an interval among the reported readings, with an end that is not finite or with its low end above its high one; a reported list with nothing in it; an uncertainty below zero |
CatalogueError |
a value beside misprinted, unquantified, not_derivable or reported on the same field; a converted or carried entry on a field that holds nothing |
CatalogueError: the first four say there is no value to serve, the last two have nothing to describe |
a value below zero in a field whose name ends in _kg_m3, _kg_m2, _kg, _kg_mol, _m_s, _pa, _pa_s_m2, _pa_s_m, _n_m3, _mm, _um, _m, _m2, _m_hz or _per_cm (a density, a mass per area, a mass, a molar mass, a speed, a pressure or modulus, a flow resistivity, a specific flow resistance, a stiffness per area, a length, an area, a thickness-frequency product, a count per centimetre); a porosity outside 0 to 1; shot_content_percent, binder_content_percent or adhered_area_percent outside 0 to 100 |
CatalogueError; a Celsius temperature, a decay rate per metre and a level in decibels stay signed |
approximate=[...] kept as the list it was given, a mapping kept as the dict |
a frozenset, and every mapping frozen all the way down, its pairs into tuples |
a subclass field annotated with a type the contract has no check for, a bare float or int included |
TypeError the first time the class is built; a field is float | None (Optional[float] is the same), int | None, bool, str, frozenset[str] or a Mapping[str, ...] of those, because every cell of a row may be missing |
PorousMaterial.frame_constants() on a row without structural_loss_factor, read as a frame that dissipates nothing |
ValueError, saying what the page had in that cell |
GroundSurface.porosity holding 26.9 to 58.1 on six rows of Cox & D'Antonio Table 6.7, which the page prints in per cent in a column of fractions that states no unit |
None, with misprinted["porosity"] quoting the figure the page prints; why_missing("porosity") and printed("porosity") say so |
Every other packaged row already met the contract, so those six porosities are the only published cells that change, and every published porous row with both moduli prints its loss factor.
from phonometry import io, materials
try:
materials.PorousMaterial(name="Panel core", source="a datasheet", porosity=97.0)
except io.CatalogueError as error:
print(error)
# 'Panel core': porosity is 97.0, and a porosity is a fraction from 0 to 1
carpet = materials.Carpet(
name="Loop pile", source="a datasheet", pile_height_mm=6.0, approximate=["pile_height_mm"]
)
print(carpet.approximate)
# frozenset({'pile_height_mm'})
A filter bank's class reads every requirement of IEC 61260-1 #
verify_filter_class graded the Table 1 mask alone. For the 2014 edition it
now also grades the effective bandwidth deviation of 5.12 and the summation of
output signals of 5.16, computed as IEC 61260-2:2016 computes them, and a
band's class and the bank's overall_class are the strictest class met on
all three. For the 1995 edition it grades the filter integrated response of
4.5.3 and the summation of output signals of 4.9 beside Table 1, as that
edition's clause 5 tests them. In both editions every band is graded at the
bank's input rate up to half of it, so a decimated band is graded on the alias
images its decimation folds onto it, and the bank's decimator keeps them more
than 125 dB down.
| Before | 4.0 |
|---|---|
| each band of a decimated bank decimated until its processing Nyquist frequency is 1.25 times its upper band edge | decimated only as far as leaves it sixteen times that edge, so the bilinear transform no longer bends the band: a band level moves by up to 0.07 dB on white noise, most in the lowest bands, and the octave bank, which would sum its outputs up to +0.94 dB and read class 2 on 5.16, is class 1 on every requirement |
a band's class read off margin_class{c}_db |
class over every requirement; margin_class{c}_db is still the Table 1 margin, beside bandwidth_margin_class{c}_db and summation_margin_class{c}_db, which is None on the two end bands |
| one requirement to ask about | requirements, requirement_class(name) and binding_margin(name, cls) read each one on its own, and plot(requirement="summation") draws it |
an edition="1995" verdict on Table 1 alone |
Table 1, "effective_bandwidth" (the filter integrated response of 4.5.3) and "summation" (4.9, run from the lowest to the highest mid-band frequency, so the end bands carry it too), both at the S that 5.3.3 raises in steps of 12 until the integrated response settles, which the result's points_per_bandwidth reports (36 for the default octave bank) |
a decimated band graded up to the Nyquist frequency of its decimated rate, checked_to_omega stopping there |
graded at the input rate up to half of it, alias images included; checked_to_omega is half the input rate over the mid-band frequency, and range_limited marks a Table 1 mask running on past it |
the anti-aliasing filter scipy.signal.resample_poly designs by default, which left the images of the octave bank at 8, 16 and 32 kHz 68.9 dB down, under the 70 dB of class 1 |
a filter of the same length sized for a 120 dB stopband, its images at least 125.4 dB down; a band level moves by under 0.01 dB |
The octave and one-third-octave banks keep class 1.
from phonometry import filters
octave = filters.verify_filter_class(
filters.OctaveFilterBank(48000, fraction=1, limits=[125, 4000]))
print(octave.overall_class, octave.requirement_class("relative_attenuation"))
# 1 1
A verdict reads its printed limit from the standard #
A verdict used to carry the limit it was judged against as a constructor
field. In 3.3.0 three did: ToneAssessment.criterion_db,
ExposureAssessment.action_value and limit_value, and
RigidMassCalibrationResult.tolerance. Six more that are newer than 3.3.0
did in 4.0.0rc1, and the rest of the table arrived after 4.0.0rc1. Anything
that built one by hand, or rewrote one with dataclasses.replace, could
judge a measurement against any number and still print the standard's name
over the result. In 4.0 every limit a standard prints is a read-only
property, read from the fields that select it: the bands, the condition, the
source, the class, the room. A verdict that was stored beside its limit is
read from the measured fields too, or checked against them when the result
is built, so it cannot contradict the limit. The functions that return these
verdicts take the same arguments and give the same answers, and every name
below, in its 4.0 spelling, still reads the same value; only code that constructs a verdict
directly, or replaces one of these fields, has to change. The last column
says where each verdict first shipped.
| Verdict | No longer constructor fields | Fields it keeps or gains | Since |
|---|---|---|---|
building.PositionSpreadCheck |
limit_db, stage, spread_db, action, next_positions, corner_standard_deviation_db |
levels, which all of them are read from |
after 4.0.0rc1 |
building.HeavyImpactSourceCheck |
frequencies, nominal, tolerance_db, deviation, within_tolerance, passes |
source, measured |
4.0.0rc1 |
noise_control.BandFlatnessCheck |
limit_db, within_limit, passes |
octave_frequencies, spread_db |
after 4.0.0rc1 |
noise_control.SourcePositionCheck |
n_required_positions, passes, exceeds_max |
n_positions_used, max_octave_spread_db |
after 4.0.0rc1 |
noise_control.EnclosureTestEnvironmentCheck |
environmental_correction_limit_db, background_margin_limit_db, required_area_ratio, passes |
base_standard, actual_area_ratio, mean_absorption_coefficient |
after 4.0.0rc1 |
environment.ReflectionGridCheck |
nominal_m, deviations_m, within |
check, path_differences_m |
after 4.0.0rc1 |
emission.HardWalledRoomCheck |
limit_db, min_volume_m3, box_dimension_limit_m, min_microphone_distance_m |
the bands, the room and the box | after 4.0.0rc1 |
emission.ReferenceSoundSourceVerdict |
every *_limit_db, adjacent_step_db, core_range_db, extended_range_db, frequency_range_met, not_judged |
the bands, the levels and the measured figures | after 4.0.0rc1 |
emission.ReferenceSourceDriftResult, emission.SpecialRoomSuitabilityCheck |
limit_db |
the bands | after 4.0.0rc1 |
emission.SpecialRoomReverberationCheck |
lower_limit, upper_limit |
the bands | after 4.0.0rc1 |
emission.IntensityInstrumentComplianceResult |
limit_class1, limit_class2, spacing_offset_db |
device, spacing_m; the band rows are read from them, see the next section |
4.0.0rc1 |
emission.InverseSquareLawResult, emission.SourceDirectionalityResult |
tolerance_db |
room selects it; the qualified radii must be the ones the levels reach |
after 4.0.0rc1 |
hearing.AmbientNoiseCheck |
limits_db, table_bands_hz |
gains earphone_attenuation and allowed_threshold_shift_db |
after 4.0.0rc1 |
hearing.FixtureIsolationVerification |
min_isolation |
the bands | after 4.0.0rc1 |
hearing.REATSoundFieldCheck |
allowable_variation_db |
gains free_field_rejection |
after 4.0.0rc1 |
hearing.DiffuseSoundFieldCheck |
allowable_variation_db |
gains front_to_random_index |
after 4.0.0rc1 |
hearing.FreeSoundFieldCheck |
axis_offset_m, inverse_distance_difference |
field and loudspeaker_distance_m select them |
after 4.0.0rc1 |
electroacoustics.ProgramSignalCheck |
offset_db, relative_levels, lower_tolerance_db, upper_tolerance_db |
frequencies, band_levels |
after 4.0.0rc1 |
electroacoustics.NeckLoopVerification |
limits |
neck_loop_type selects it |
after 4.0.0rc1 |
psychoacoustics.ToneAssessment |
prominence_limit_db, prominent |
gains method, "tone_to_noise_ratio" or "prominence_ratio" |
3.3.0 |
underwater.WeightedExposureResult |
criteria |
gains impulsive |
4.0.0rc1 |
vibration.ExposureAssessment |
action_value, limit_value, exceeds_action, exceeds_limit, zone |
value, kind, metric |
3.3.0 |
vibration.PhaseVerification, vibration.WeightingVerification |
tolerance_deg (phase), within_tolerance |
the weighting and the frequencies | 4.0.0rc1 |
vibration.RunningRMSDecayVerification |
printed_time_s, tolerance_s |
method, integration_time, measured_time_s |
after 4.0.0rc1 |
vibration.SignalBurstVerification |
printed, deviation_percent, tolerance_percent, within_tolerance |
the table row, the columns and measured |
4.0.0rc1 |
vibration.VibrationMeterVerification |
lower_percent, upper_percent, within_tolerance |
gains measured_response |
after 4.0.0rc1 |
vibration.AssessmentVelocity |
guide_value_mm_s |
building_class selects it |
after 4.0.0rc1 |
vibration.MountingCheck |
passes, frequency_limit_hz, peak_acceleration_limit_m_s2, device |
gains peak_acceleration_m_s2 and upper_frequency_hz |
after 4.0.0rc1 |
vibration.DamageAssessment |
guideline_mm_s |
gains massive_structure, by name only |
4.0.0rc1 |
vibration.RigidMassCalibrationResult |
expected, relative_deviation, within_tolerance, passes, relative_tolerance |
frequencies, measured, mass, quantity |
3.3.0 |
vibration.LevelDifferenceCheck |
limit_db |
condition selects it |
after 4.0.0rc1 |
vibration.OutputMassCheck |
mass_limit_kg |
gains output_apparent_mass_kg, the measured output force over output acceleration |
after 4.0.0rc1 |
Two calls change too. rigid_mass_calibration_check, now
verify_rigid_mass_calibration, no longer takes tolerance: ISO 7626-2:2015 7.5.2 says the block "shall agree within ±5 %",
so a tighter in-house acceptance is read from .relative_deviation instead. And
HeavyImpactSourceCheck and RigidMassCalibrationResult, whose passes was a
stored field, refuse to be read as a truth value like every other verdict, so
if check: raises TypeError and the verdict is .passes.
import dataclasses
from phonometry import vibration
check = vibration.check_blocked_output(frequencies=[100.0, 200.0], input_acceleration_level=[90.0, 95.0], output_acceleration_level=[60.0, 70.0])
print(check.limit_db, check.passes)
# 20.0 True
try:
dataclasses.replace(check, limit_db=10.0)
except TypeError as error:
print(type(error).__name__)
# TypeError
calibration = vibration.verify_rigid_mass_calibration([0.104, 0.093], frequencies=[50.0, 500.0], mass=10.0)
print(calibration.relative_tolerance, calibration.within_tolerance.tolist())
# 0.05 [True, False]
The limits a standard leaves to the user stay fields: the "default" roughness
and decay-rate limits of ISO 3095, the tolerance ISO/DIS 16032 7.6 does not
print for "approximately 30 s", the curing period a product specification
sets under ISO 10140-1 G.4, the threshold shift ISO 8253-1 lets the tester
accept, and the specification limits, test-case limits and limit rows the
caller passes to the conformance, ISO 17534-1 and RD 1367/2007 checks. The
requirement records of ISO 8297 and IEC 60118-4, PlantRequirement and
LoopRequirement, also keep each row's limit as a field: one record type
holds requirements whose limits mix printed figures with the plant's geometry,
the specified field strength or the noise measured with the loop off.
A verdict is read from the values it holds #
The section above took the printed limits out of the constructors. The verdict
flags stayed in: passes, qualified, every *_met and *_ok,
the advisories, and the class of each band of a filter, weighting or intensity
instrument verdict. The function that built a result worked them out and
stored them beside the readings they came from, so a result built by hand, or
rewritten with dataclasses.replace, could hold readings that fail and a flag
that says they pass. In 4.0 every one of them is a read-only property, read
from the values the result holds and the limit the standard prints. A result
keeps what its verdict is read from: the readings, the margins, the positions,
the measured figures. A figure that only fed the verdict, such as the rounded
level of an RD 1367/2007 period or the share of raindrops inside their
tolerance, is a property too. The functions that return these results take the
same arguments and return the same verdicts, and every name in the table still
reads the same value; only code that builds one of these results directly, or
replaces one of the listed fields, has to change. "By name only" marks a field
that is keyword-only.
| Result | No longer constructor fields | Read from | Since |
|---|---|---|---|
building.JointTestElementCheck |
length_ok, width_ok, passes |
joint_length_m, joint_width_mm, window_or_door_gap |
after 4.0.0rc1 |
building.GapWidthCheck |
gap_width_mm, spread_mm, enough_positions, uniform, passes |
readings_mm |
after 4.0.0rc1 |
building.JointGapSeriesCheck |
nominal_measured, min_measured, working_range_measured, passes |
gap_widths_mm, nominal_gap_mm, min_gap_mm |
after 4.0.0rc1 |
building.LiningCuringCheck |
cured, lag_within_third, passes |
curing_time_days, time_lag_days, required_curing_days |
after 4.0.0rc1 |
building.RainGeneratorVerification |
rate_deviation_mm_h, rate_ok, drop_share, drops_ok, velocity_share, velocities_ok, passes |
rain_type, rainfall_rate_mm_h, drop_diameters_mm, fall_velocities_m_s |
after 4.0.0rc1 |
building.ServiceEquipmentPositionCheck |
separation_m, surface_distance_m, source_distance_m, heights_m, corner_height_m, corner_wall_distances_m and the six *_ok |
the room, the corner and the positions | after 4.0.0rc1 |
building.DBHRCheck |
reported, margin, passes |
requirement, value |
4.0.0rc1 |
building.LowFrequencyIntensityResult, building.LowFrequencyElementResult |
qualified |
surface_pressure_intensity_indicator, against the 6.4.2 limit absorbing_specimen_surface selects |
4.0.0rc1 |
electroacoustics.BackgroundNoiseAssessment |
reference_signal_to_noise_ratio_db, category, report_required |
noise_levels, noise_is_tonal |
after 4.0.0rc1 |
electroacoustics.FeedbackStabilityResult |
is_stable |
loop_gain, stability_margin |
4.0.0rc1 |
emission.FreeFieldCheck |
room, frequencies, band_radius_m, max_qualified_radius_m, every *_met, full_frequency_range, conforming_range_hz, conforming_radius_m, not_judged |
the arguments of check_free_field: gains source_directionality, reflecting_plane_absorption_coefficient, reflecting_plane_margin_m, paths_in_working_area, speed_of_sound |
after 4.0.0rc1 |
emission.IntensityInstrumentComplianceResult |
bands, overall_class, range_limited |
frequencies, residual_index, device, spacing_m |
4.0.0rc1 |
emission.ReferenceSourceCalibration |
sound_power_level, intensity_bands, intensity_agreement, room_qualified |
gains intensity_sound_power_level and room_qualification |
after 4.0.0rc1 |
emission.HardWalledSoundPowerResult |
background_requirement_met, upper_bound |
gains background_margin_db, reference_background_margin_db |
after 4.0.0rc1 |
emission.InSituSoundPowerResult |
background_requirement_met, upper_bound, grade, sigma_r0, sigma_tot, expanded_uncertainty |
gains background_margin_db, reference_background_margin_db, the smallest over the positions, and excess_levels, directivity_range_db, the two indicators Table 2 grades by |
4.0.0rc1 |
emission.SpecialRoomSoundPowerResult |
background_requirement_met, background_requirement_met_a |
gains background_margin_db, reference_background_margin_db, background_margin_a_db |
after 4.0.0rc1 |
emission.EmissionPressureResult |
upper_bound |
gains background_margin_db, by name only |
4.0.0rc1 |
emission.PrecisionCriteria |
criterion_1 to criterion_5, qualified |
gains the readings: indicators, scan_intensity_level_1, scan_intensity_level_2, frequencies, repeatability_limit_db, pressure_residual_index, field_nonuniformity_1, field_nonuniformity_2 |
3.3.0 |
emission.DiscretePointIntensityResult |
everything but the indicators and the grade: partial_power, sound_power, sound_power_level, achieved_grade, both criteria, the A-weighted figures and the rest |
gains normal_intensity, segment_areas_m2, pressure_residual_index, fraction |
4.0.0rc1 |
emission.TurbineTestEnvironmentCheck |
correction_ok, wind_ok, windscreen_advised |
environmental_correction, ratio, wind_speed_m_s |
after 4.0.0rc1 |
environment.ImpulseOnset |
level_difference, prominence, qualifies |
level_start, level_end, onset_rate |
3.3.0 |
environment.ImpulseProminenceResult |
per_impulse, qualifies, prominence, adjustment |
onset_rates, level_differences, assessment_period_minutes |
3.3.0 |
environment.ResidualCorrectionResult |
reliable |
margin |
3.3.0 |
environment.PeriodAssessment |
reported_level, reported_long_term, max_phase_level, phase_pass, daily_pass, long_term_pass |
phases, the two levels and limit; gains new_activity, by name only |
4.0.0rc1 |
environment.ModulationPeriod |
modulation_depths_db, fundamental_frequencies_hz, n_valid_blocks, rated, rating_db, mean_modulation_frequency_hz, mode_modulation_frequency_hz |
blocks |
after 4.0.0rc1 |
environment.SoundRelevantTurbines |
relevant, total_level, relevant_level |
predicted_levels |
after 4.0.0rc1 |
environment.WindShearProfile |
typical |
shear_exponent |
after 4.0.0rc1 |
environment.WindTurbineTonalityResult |
is_audible |
tonal_audibility, has_identified_tone, itself read-only (next section) |
3.3.0 |
filters.FilterComplianceResult |
bands, overall_class, range_limited |
gains band_margins, the rows without their class |
3.3.0 |
filters.WeightingComplianceResult |
bands, overall_class, range_limited |
gains band_margins, the rows without their class |
4.0.0rc1 |
hearing.AscendingThresholdResult |
threshold_level, determined, series_exhausted |
ascent_levels, shortened |
after 4.0.0rc1 |
hearing.TaskContribution |
spread_advisory |
n_samples, sample_range_db |
3.3.0 |
hearing.ExposureResult |
sampling_advisory |
gains sample_range_db, n_workers, sample_duration_hours, by name only |
3.3.0 |
hearing.AttenuationDifferenceResult |
difference, significance_limit_db, significant |
the two means and their expanded uncertainties | after 4.0.0rc1 |
materials.CeilingSpecimenCheck |
area_error_m2, deflection_ok, substructure_ok, fixture_ok, supports_ok, humidity_ok, ce_marking_depth, passes |
gains the measured figures: deflection_mm, substructure_width_mm, substructure_height_mm, fixture_density_kg_m2, support_width_mm, support_height_mm, support_center_distance_m, lowest_relative_humidity_percent |
after 4.0.0rc1 |
metrology.TrendTestResult |
trend_free, bounds |
statistic, against the region values, method, alpha and median give |
3.3.0 |
metrology.StationarityTestResult |
stationary, bounds |
trend_statistic, against the region segment_values, method and alpha give |
3.3.0 |
metrology.CouplerCheck |
ratio_recommended, approximation_valid, full_solution_advised, conditions_valid |
gains heat_conduction_method, temperature_c, static_pressure_pa, relative_humidity_percent, in_air, by name only |
after 4.0.0rc1 |
metrology.FreeFieldArrangementCheck |
distances_ok, support_ok, annex_a_range, attenuation_accuracy |
gains air_attenuation |
after 4.0.0rc1 |
noise_control.CabinUncertainty |
ratio_satisfied, stateable, stated_band_range_hz, increased_uncertainty_band_range_hz, excess_standard_deviation_db |
method, volume_ratio |
after 4.0.0rc1 |
room.RoomAcousticsResult |
edt_valid, t20_valid, t30_valid |
dynamic_range and the decay times |
3.3.0 |
room.BackgroundMarginCheck |
needs_correction, unusable, passes |
margins_db |
after 4.0.0rc1 |
room.PredictionDetailCheck |
passes, room_ok, fittings_ok, sources_ok |
gains room_detail, fitting_detail, source_detail |
after 4.0.0rc1 |
underwater.WeightedExposureResult |
exceeds_injury, exceeds_tts |
sel_margin, peak_margin, tts_margin, tts_peak_margin |
4.0.0rc1 |
vibration.PeopleAssessment |
passes, criterion, within_uncertainty |
kb_fmax, kb_ftr, guide, source; gains rare_short_events, by name only |
after 4.0.0rc1 |
vibration.RailwayChange |
passes, kb_fmax_met, kb_ftr_met, kb_fmax_increase_percent, kb_ftr_increase_percent |
gains kb_fmax_before, kb_fmax_after, kb_ftr_before, kb_ftr_after |
after 4.0.0rc1 |
vibration.TransferStiffnessResult |
valid |
gains transmissibility, |T| of the indirect method |
3.3.0 |
vibration.DrivingPointStiffnessResult |
adequate |
gains blocked_output_difference, unwanted_input_difference |
after 4.0.0rc1 |
aircraft.AircraftSystemComplianceResult |
passes, checks |
gains directional, frequency_response, linearity, resolution, the arguments of verify_aircraft_noise_system |
4.0.0rc1 |
broadcast.QuasiPeakDynamicsResult |
passes, worst_margin_db, worst_deviation_db, stimuli |
gains readings_percent, the eleven readings in the order of Tables 2 and 3 |
4.0.0rc1 |
building.FloorCoveringImprovementResult |
limited |
gains background_margin_db, the smallest margin over the positions and both floors |
3.1.0 |
building.VibrationReductionResult |
single_number, bracketed |
frequencies, k_ij; gains modal_overlap, fraction |
3.1.0 |
building.ServiceEquipmentBackgroundResult |
difference, correction, corrected_levels, regime |
measured_levels, background_levels |
after 4.0.0rc1 |
building.ServiceEquipmentResult |
standardizable |
frequencies, fraction |
after 4.0.0rc1 |
emission.SoundPowerIntensityResult |
partial_power_level, sound_power, sound_power_level, negative_band, negative_partial_power_index, dynamic_capability_index, achieved_grade, a_weighting_omitted_bands, sound_power_level_a |
partial_power and the indicators; gains pressure_residual_index, fraction, repeatability_limit_db |
3.1.0 |
emission.PrecisionIntensityResult |
sound_power, sound_power_level, sound_power_level_normalized, not_applicable_band, sound_power_level_a |
partial_power; gains temperature_c, static_pressure_pa, by name only |
3.1.0 |
emission.InDuctSoundPowerResult |
information_only_band |
frequencies, flow_velocity |
4.0.0rc1 |
emission.SourceLocationPlan |
spectral_character, a_weighted_spectral_character |
standard, standard_deviation_db, a_weighted_standard_deviation_db |
after 4.0.0rc1 |
environment.ImpulsiveSoundResult |
prominence, adjustment, category, adjusted_laeq |
onsets, laeq |
3.3.0 |
environment.ModulationBlock |
status |
prominence; gains excluded, by name only |
after 4.0.0rc1 |
environment.ReferenceTrackCheck |
conditions |
the roughness, the decay rates and the limits; gains curve_radius_m, track_gradient_ratio, by name only |
after 4.0.0rc1 |
FilterComplianceResult and WeightingComplianceResult hold their per-band
rows as band_margins: the rows bands held, without the "class" key. A
row that states a class is refused, and the bands property adds to each row
the class its margins earn, so result.bands[i]["class"] reads as before.
IntensityInstrumentComplianceResult takes no band rows at all: it holds the
frequencies and the measured pressure-residual intensity index, and reads the
rows, the class and range_limited from them, the device and the microphone
separation.
The rows a verdict is read from are read-only. band_margins and
between_nominals are copied into read-only mappings when the result is
built, so a write into one raises TypeError and a later write into the
dictionaries you built it from does not move the class; copy a row with
dict(row) to change it, since copy.deepcopy cannot copy a read-only
mapping. The rows of AircraftSystemComplianceResult.checks,
QuasiPeakDynamicsResult.stimuli and ReferenceTrackCheck.conditions are
built from what the result holds and the tables of the standard each time
they are read.
import dataclasses
from phonometry import building, filters
gap = building.check_gap_width([5.0, 5.1, 5.2, 5.1])
print(gap.passes, round(gap.spread_mm, 1))
# True 0.2
try:
dataclasses.replace(gap, passes=False)
except TypeError as error:
print(type(error).__name__)
# TypeError
wider = dataclasses.replace(gap, readings_mm=(5.0, 5.1, 5.6, 5.1))
print(wider.uniform, wider.passes)
# False False
bank = filters.OctaveFilterBank(fs=48000, fraction=1, order=6, limits=[125, 4000])
result = filters.verify_filter_class(bank)
print(result.overall_class, result.bands[0]["class"], "class" in result.band_margins[0])
# 1 1 False
A flag stays a field where it is no verdict against a limit and nothing the
result holds decides it: an option the caller sets, such as small_room or
noise_is_tonal; a branch the caller chose by what they gave, such as
InverseSquareLawResult.origin_fitted; a fact of an input the result does not
keep, such as TimeWeightedEnvelope.calibrated; a property of the file read;
whether an iterative solver converged; and a column of a published table row.
CriticalCouplingResult.converged keeps the outcome of its solve, which the
result cannot run again, but it can no longer claim convergence beside an
absorption that does not exceed 0.999, the third condition of the flag.
A regime the result could read from its own values is a verdict, and the next
section lists the ones that moved. PlantRequirement and LoopRequirement do not change: their rows
keep each limit as a field for the reason the section above gives, and
PlantRequirement.holds stays beside it. TrackCondition keeps its holds
as a row of the report, but ReferenceTrackCheck builds its conditions from
the track it holds, so no verdict reads one built elsewhere. The yes/no
checks of SoundLevelMeterPeriodicRequirement stay as well: they are what
the tester saw, an overload indicated or an indicator latched, not a limit
judged.
A result reads its regime from the values it holds #
Some results stored a regime or a classification beside the values it was read from: the regime of a valve, whether a hammer rebounds, whether terrain screens a path, whether a tone was found, whether a synchronous average had to interpolate. The function compared values the result holds, or could hold, with a constant or a threshold its source prints, and stored the answer, so a result built by hand could hold the stiffness of an under-critical hammer and say it is over-critical. In 4.0 each of them is a read-only property, read from the values the result keeps, and a result that did not keep what the test reads now keeps it, with the unit in the name. "By name only" marks a field that is keyword-only.
A value exactly on a boundary falls where the source puts it. Hopkins prints the over-critical case as K m ≥ 4 Zdp², so critical damping is over-critical, and IEC TS 61400-11-2 asks for a total "at least 3 dB" above the background before the logarithmic subtraction, so a difference of 3 dB takes it. IEC 60534-8-4 does not settle its cavitation threshold one way: the test of 5.1 leaves the threshold itself to neither side, the region of Equation (9) and Equation (19b) put it with the cavitating points, and 4.1, Equation (18b) and 6.3 with the turbulent ones. The library reads it as turbulent, where Equation (9) returns zero and the two branches meet without a step.
The functions take the same arguments and return the same numbers. Code that
builds one of these results directly, or replaces one of the fields its regime
is read from, has to change, and so does code that reads fraction from
vibration_reduction_index (see below the table).
| Result | No longer a constructor field | Read from | Since |
|---|---|---|---|
building.TappingForceResult |
over_critical, K m ≥ 4 Zdp² (Hopkins Eq. 3.95) |
contact_stiffness, impedance; gains mass, by name only |
4.0.0rc1 |
noise_control.HydrodynamicValveNoise |
regime, cavitating when Δp exceeds x_Fzp1 (p1 - pv) (IEC 60534-8-4 5.1) |
differential, corrected_ratio; gains inlet_pressure_pa, vapor_pressure_pa |
4.0.0rc1 |
noise_control.AerodynamicValveNoise |
regime, the five intervals of IEC 60534-8-3 5.2 |
pressure_ratio, boundaries; gains specific_heat_ratio, pressure_recovery, efficiency_correction, by name only |
4.0.0rc1 |
aircraft.TerrainScreeningResult |
screened, terrain strictly above the line of sight |
source, receiver, distances_m, heights_m |
3.3.0 |
hearing.AutomaticThresholdResult |
is_peak, retained (ISO 8253-1 6.3.5 a)) |
reversal_levels |
after 4.0.0rc1 |
hearing.SweepThresholdResult |
is_peak |
reversal_levels |
after 4.0.0rc1 |
metrology.WaveMotionCorrection |
interpolated |
frequencies, speed_of_sound_ratio |
after 4.0.0rc1 |
noise_control.CabinInsulationResult |
apparent (ISO 11957 3.6) |
method |
after 4.0.0rc1 |
noise_control.WeightedCabinInsulation |
apparent (ISO 11957 3.9) |
method, which weighted_cabin_insulation now takes as cabin_insulation does |
after 4.0.0rc1 |
environment.WindTurbineTonalityResult |
has_identified_tone (IEC 61400-11 9.5.2 to 9.5.4) |
levels, frequencies; gains candidate_frequency_hz, by name only |
3.3.0 |
building.LaboratoryJointInsulationResult |
regime (ISO 10140-1 J.1) |
r_s_prime, r_s_max; gains limit_at_max, by name only |
after 4.0.0rc1 |
environment.TurbineSoundLevels |
regimes (IEC TS 61400-11-2 11.7) |
total_levels, background_levels |
after 4.0.0rc1 |
underwater.WestonPropagationResult |
regime |
range_m, boundaries |
4.0.0rc1 |
signals.SynchronousAverageResult |
interpolated, f_s T not a whole number of samples |
fs, period_s |
4.0.0rc1 |
building.VibrationReductionResult.fraction is a field, the band set the
caller states: octave_bands() states fraction=1, since a single octave band
cannot be told from a one-third-octave band by its spacing.
vibration_reduction_index no longer fills it with the band set it read from
the frequencies; it leaves None, and the result reads the spacing each time
it takes the Annex A mean, which gives the same mean as before.
The numbers a regime selects are held to it, so a result built by hand can no longer carry one regime beside the values of another. When it is built, each of these results refuses:
TappingForceResult: a cut-off frequency, a limiting frequency, a force spectrum or a power input that is not what K, Zdp and m give in their regime, and limits of Eqs. (3.99) and (3.100) that are not a factor of 2 apart.HydrodynamicValveNoise: a vapour pressure at or above the inlet pressure; an x_F or an x_Fzp1 that is not what Equation (1) or (3c) gives from the fields beside it; a point at or past flashing, x_F = 1; cavitation fields on a turbulent point, or none on a cavitating one.AerodynamicValveNoise: boundaries that are not those of its gas and its trim, and a Mach number or an acoustical efficiency of another regime.TerrainScreeningResult: a source or a receiver that is not a finite point, a source at or past the receiver, a section that does not run from one to the other, and a path difference or diffracting edges that are not those of the rubber band over that section.AutomaticThresholdResultandSweepThresholdResult: reversals that do not alternate, a tracing that keeps no peak or no valley, and a mean, a threshold or a running threshold that is not what the reversals give.WaveMotionCorrection: a frequency beyond the last row of Table C.3, and a correction the table does not give at its frequency.CabinInsulationResult: an A-weighted insulation under any method but the actual noise.WindTurbineTonalityResult: a candidate that is not a line of the spectrum at or above 20 Hz, and a Formula 30 to 34 chain that is not the one the spectrum gives about it.LaboratoryJointInsulationResult: a corrected index of another rule of J.1.TurbineSoundLevels: a level difference other than the total less the background, a turbine level of another rule of 11.7, and an uncertainty on a bin whose level cannot be determined.WestonPropagationResult: a composite loss that is not the law of the regime in force.SynchronousAverageResult: a period grid other thanround(fs * period_s)samples.
import dataclasses
import numpy as np
from phonometry import building
bands = np.array([100.0, 200.0, 400.0, 800.0])
force = building.tapping_force_spectrum(bands, 1.0e6, 3.0e4)
print(force.over_critical)
# False
print(building.tapping_force_spectrum(bands, 1.0e6, 100.0).over_critical)
# True
try:
dataclasses.replace(force, impedance=100.0)
except ValueError as error:
print("cut_off_frequency" in str(error))
# True
A wrong type raises TypeError, a missing key KeyError, and every warning has a topic #
The Python documentation draws the line between the two refusals:
TypeError is "raised when an operation or function is applied to an object
of inappropriate type", and ValueError "when an operation or function
receives an argument that has the right type but an inappropriate value". In
3.3.0 and 4.0.0rc1 seventy-six refusals asked an argument for its type and
raised ValueError, thirty-two more caught a TypeError and raised it again
as a ValueError, and the shared guards of every scalar parameter refused an
array that way too, while a handful of others raised TypeError for the same
mistake. 4.0 raises TypeError for a wrong type and ValueError for a
right type with a wrong value, everywhere. A call wrapped in except ValueError to absorb any bad input should catch (TypeError, ValueError).
| Passed | 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|---|
an array, None, a text or an object that is not a number where one number belongs, on any scalar parameter |
ValueError, and a text that reads as a number, such as "20", was taken as that number |
TypeError, naming the parameter, for "20" and "fifty" alike: a text is the wrong type where a number belongs, whatever it reads as |
an element that is not a number inside an array of numbers ([None, 1.0], ["94.0", "94.1"]) |
ValueError, and text numpy reads as numbers was taken as them |
TypeError, for text whatever it reads as |
| a complex number or array where a real one belongs, on any parameter the shared guards read | ValueError |
TypeError, saying it must be real |
an array of the wrong kind: a mask that is not boolean (obstacle_mask= of simulation.FDTD2D and simulation.fdtd_simulation, the region masks of simulation.ElasticFDTD2D.from_regions, valid= of vibration.band_averaged_stiffness), line_counts of vibration.BandAveragedStiffness that are not integers, exclusion flags that are neither booleans nor integers (excluded_blocks= of environment.amplitude_modulation_period, excluded= of environment.bin_amplitude_modulation), text where the readings, distances and durations of the service equipment functions of building belong (building.verify_calibration_deviation, building.check_background_duration and the rest) |
ValueError |
TypeError |
a sequence where one measurement belongs: the pressures and temperatures of noise_control.normal_air_density, noise_control.total_pressure, noise_control.total_pressure_loss and noise_control.pressure_loss_coefficient, altitude of emission.static_pressure_from_altitude, tolerance_s= of building.check_background_duration |
ValueError, and the noise_control functions read a one-element sequence as its element |
TypeError, a one-element sequence included |
a whole number (a count, an index, a class, a number of points or of decimals: any parameter written as an int) given as a text, a bool or an array: signals.zoom_fft(..., n_points=), signals.window_metrics(window, n), signals.min_phase(..., oversample=), electroacoustics.swept_sine_distortion(..., n_harmonics=), metrology.stationarity_test(..., n_segments=), vibration.story_fundamental_frequency(n_stories), n_events= of the sound energy functions and of emission.SoundEnergyResult and emission.ReverberationSoundEnergyResult, n= of building.prediction_input_uncertainty and building.intensity_element_normalized_difference, oversample= of signals.lc_peak and broadcast.true_peak_level, max_order= of room.image_source_rir and room.audible_image_count, the grid indices and step counts of simulation.FDTD2D, duration_days= of vibration.construction_guide_values, start_band= of aircraft.tone_correction, n_level_ranges= of metrology.SoundLevelMeterFeatures, n_impacts of vibration.ImpactMobilityResult, the position counts of ReportMetadata |
ValueError, or, where the value went through int(), a bool taken as 0 or 1, a text parsed and a fraction truncated without a word (n_points=100.6 drew 100 points) |
TypeError. A number that is not whole, or is below the least the count can be, is a ValueError, and a whole float such as 5.0 is taken as 5 |
a flag that is not True or False: small_room= of building.check_service_equipment_positions, absorbing_specimen_surface= of the ISO 15186 insulation, the declarations of the free-field qualification in emission, the features of metrology.SoundLevelMeterFeatures and the observations of metrology.SoundLevelMeterPeriodicMeasurements |
ValueError |
TypeError |
a name that is not a text: the area types, uses and periods of the RD 1367/2007 and DB-HR functions (environment.activity_limits and the rest), the Annex A items of environment.SoundscapeAcousticEnvironment, the descriptions of emission.turbine_noise_declaration, and any choice among named options given as something other than a text (period=5) |
ValueError |
TypeError; an empty text, or a text that names none of the options, stays a ValueError |
an object of the wrong class: the boxes of emission.turbine_measurement_surface, surface= of emission.turbine_microphone_positions, correction= of emission.check_turbine_test_environment, the determinations of emission.turbine_noise_declaration, the parts of environment.SoundscapeReport, a material of the elastic FDTD that is no Material, catalogue row or triple, a waveform that is not callable, a bare array to io.write(..., sidecar=True), a band calibration where emission.high_frequency_sound_power_comparison compares tones |
ValueError |
TypeError |
a text where a sequence belongs, a number where a pair or a list does, or a pair holding an array: rankings of environment.method_b_source_ranking, bands= of environment.bin_amplitude_modulation, exclude_hz= and the frequency pairs of the ISO 7626-5 mobility, microphones= of the IEC 61094-8 corrections, the limits of a filter bank, shape= of simulation.FDTD2D, the band edges of electroacoustics.LoudspeakerCharacteristics and electroacoustics.MicrophoneCharacteristics |
ValueError |
TypeError |
a performance of hearing.assumed_protection_value or hearing.hml_rating that is not a number, a clause= of metrology.max_expanded_uncertainty that is not a number, a part= of environment.method_a_scale_values that is a bool |
ValueError |
TypeError; a number Table 1 does not tabulate, or a clause or part that does not exist, stays a ValueError |
A lookup that misses raises what a mapping raises when the result is read
like one, and ValueError when a number falls outside what it covers:
| Asked | 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|---|
RegulationLimits[period] for a period it does not hold |
ValueError |
KeyError. The key is matched exactly, as a dict key is: limits["Day"] and limits[" night "], which were read as "day" and "night", now raise KeyError too. The period of environment.PeriodAssessment, a choice, still raises ValueError |
emission.measurement_positions("hemisphere", ..., n_reflecting_planes=3, grade="survey") |
NotImplementedError |
the positions 14, 21 and 22 of ISO 3746:2010 Table B.2 |
emission.measurement_positions("hemisphere", ..., grade="survey") over one reflecting plane |
positions 4, 5, 6 and 10 of ISO 3744 Table B.1, the array for a source with tones | positions 4, 5, 6 and 10 of ISO 3746:2010 Table B.1, which clause 8.2.1 prescribes: the broadband positions of those numbers in ISO 3744 Table B.2 |
fluids.FluidPropertyUnavailable |
the exception | fluids.FluidPropertyUnavailableError, still an AttributeError, so hasattr and getattr with a default behave as before |
These warnings now derive from PhonometryWarning, each with a topic of its
own, so warnings.simplefilter("error", phonometry.PhonometryWarning) reaches
all of them and a filter on the topic reaches one. They are still
UserWarnings, so a filter written on that class still matches:
| Emitted by | 3.3.0 or 4.0.0rc1 | 4.0 |
|---|---|---|
environment.sound_absorption_rating and environment.sound_reflection_rating at the 0,99 cap |
environment.RoadDeviceWarning, a UserWarning outside the hierarchy |
environment.RoadDeviceWarning, a PhonometryWarning |
building.equivalent_impact_level, building.weighted_lining_improvement and building.lining_improvement outside the range their relation is stated for |
UserWarning |
building.BuildingPredictionWarning |
building.intensity_element_normalized_difference with n > 1 |
UserWarning |
building.LaboratoryInsulationWarning |
room.room_criterion on a spectrum missing a band from 31.5 Hz to 4000 Hz |
UserWarning |
room.NoiseCriterionWarning |
aircraft.approach_profile on a Level-Idle step whose start altitude or start CAS disagrees with the following Level-Idle step (Doc 29 B7.1.4) |
UserWarning |
aircraft.FlightProfileWarning, which also reports a following step that is neither Level-Idle nor Descend-Idle (Case 2) |
signals.tone_burst when fs and frequency are incommensurate |
PhonometryWarning |
signals.ToneBurstWarning |
underwater.normal_modes, underwater.eigenrays and underwater.gaussian_beams |
PhonometryWarning |
underwater.NumericalPropagationWarning |
a filter bank dropping the bands above the Nyquist frequency (Low sampling rate) |
PhonometryWarning |
filters.FilterBankWarning |
import phonometry
from phonometry import environment, vibration
limits = environment.activity_limits("a")
try:
limits["noon"]
except KeyError:
print("KeyError")
for n_stories in ("5", 2.5):
try:
vibration.story_fundamental_frequency(n_stories)
except (TypeError, ValueError) as refusal:
print(type(refusal).__name__)
print(issubclass(environment.RoadDeviceWarning, phonometry.PhonometryWarning))
# KeyError
# TypeError
# ValueError
# True
The seventy-eight names that are gone #
Everything else moved. These seventy-eight exist in no public module:
| Gone | What to write instead |
|---|---|
octavefilter, getansifrequencies, normalizedfreq |
filters.octave_filter, filters.nominal_frequencies, filters.normalized_frequencies. These were the original PyOctaveBand spellings, renamed in 3.1 and kept as aliases until 4.0 |
calculate_sensitivity |
metrology.sensitivity, the same 3.1 rename |
filter_class_compliance |
filters.verify_filter_class |
air_density_iso, speed_of_sound_iso |
materials.air_density_iso10534, materials.speed_of_sound_iso10534, and read the kelvin warning above |
speed_of_sound |
materials.speed_of_sound_iso17497(temperature_c=...), the same ISO 17497-1 formula and the same number. Not fluids.air(...).speed_of_sound, which computes humid air by another model: 343.99 m/s against 343.20 m/s at 20 °C, as the section on the obvious fix says |
depth_to_pressure |
fluids.depth_to_gauge_pressure_mpa(depth_m=...), which returns the same number, or fluids.depth_to_absolute_pressure_pa for the absolute one. Both are keyword-only and both take an optional latitude_deg |
TransmissionLossResult |
PropagationLossResult, with .tl renamed to .pl |
partial_exposure |
vibration.daily_exposure, called with one operation's value and duration. partial_exposure was a second name for the same function, and the number does not move |
insitu_reflection_factor, insitu_absorption_from_reflection, insitu_absorption_coefficient, insitu_absorption_spectrum, InsituAbsorptionResult |
materials.in_situ_reflection_factor, materials.in_situ_absorption_from_reflection, materials.in_situ_absorption_coefficient, materials.in_situ_absorption_spectrum, materials.InSituAbsorptionResult: in situ is spelled in_situ everywhere, as the building, emission and noise-control in-situ names already were |
DEFAULT_SPEED_OF_SOUND |
materials.ISO13472_SPEED_OF_SOUND_M_S, the 340 m/s of ISO 13472-1 Annex A. The 343 m/s the room modules default to is private now; pass speed_of_sound= to say which you mean |
OCTAVE_BANDS, THIRD_OCTAVE_BANDS |
materials.RATING_OCTAVE_BANDS_HZ, materials.RATING_THIRD_OCTAVE_BANDS_HZ, the bands of the ISO 11654 rating |
BASE_PLATE_BANDS |
materials.BASE_PLATE_BANDS_HZ |
DEFAULT_POLAR_ANGLES |
materials.DEFAULT_POLAR_ANGLES_DEG |
DEFAULT_MIC_HEIGHT, DEFAULT_SOURCE_HEIGHT |
materials.DEFAULT_MICROPHONE_HEIGHT_M, materials.DEFAULT_SOURCE_HEIGHT_M |
PART1_FREQUENCY_RANGE, SPOT_FREQUENCY_RANGE, SPOT_NARROW_BAND_RANGE |
materials.PART1_FREQUENCY_RANGE_HZ, materials.SPOT_FREQUENCY_RANGE_HZ, materials.SPOT_NARROW_BAND_RANGE_HZ |
REFERENCE_ACCELERATION |
vibration.ACCELERATION_LEVEL_REFERENCE_M_S2, the 1 µm/s² of ISO 1683. vibration.REFERENCE_ACCELERATION_M_S2 is another thing, the Table 1 reference conditions of ISO 8041-1 |
REFERENCE_AREA |
building.REFERENCE_AREA_M2 |
REFERENCE_VELOCITY |
emission.REFERENCE_VELOCITY_M_S |
DEFAULT_FREQUENCIES |
environment.DEFAULT_FREQUENCIES_HZ |
NOY_BANDS |
aircraft.NOY_BANDS_HZ |
UNDERWATER_REFERENCE_PRESSURE |
underwater.UNDERWATER_REFERENCE_PRESSURE_PA |
UNDERWATER_REFERENCE_EXPOSURE |
underwater.UNDERWATER_REFERENCE_EXPOSURE_PA2_S, the 1 µPa² s of ISO 1683 in Pa² s |
NORMALIZED_IMPEDANCE |
emission.NORMALIZED_IMPEDANCE_PA_S_M, the 411 Pa s/m of ISO/TS 7849 |
NO_TONE_AUDIBILITY |
psychoacoustics.NO_TONE_AUDIBILITY_DB |
REFERENCE_STIFFNESS |
vibration.REFERENCE_STIFFNESS_N_M |
HAV_EAV_A8, HAV_ELV_A8, WBV_EAV_A8, WBV_ELV_A8 |
vibration.HAV_EAV_A8_M_S2, vibration.HAV_ELV_A8_M_S2, vibration.WBV_EAV_A8_M_S2, vibration.WBV_ELV_A8_M_S2, the A(8) values of Directive 2002/44/EC. WBV_EAV_VDV and WBV_ELV_VDV keep their names, because a vibration dose value has the one unit, m/s^1.75 |
combine_uncertainties |
metrology.combined_standard_uncertainty, the one root-sum-square, which takes the contributions as one sequence: combine_uncertainties(3.0, 4.0) is combined_standard_uncertainty([3.0, 4.0]) |
combine_uncertainty |
metrology.uncertainty_propagation, the GUM propagation through a model, with the same model, quantities and correlation |
expanded_uncertainty |
building.insulation_expanded_uncertainty(u, coverage, one_sided=...), the ISO 12999-1 function the 3.3.0 top-level name forwarded to, with the same number: expanded_uncertainty(1.2) and insulation_expanded_uncertainty(1.2) are both 2.352 dB. The GUM expanded uncertainty of a propagated result is result.expanded(coverage). environmental.expanded_uncertainty, the ISO 1996-2 function of the same name, is environment.environmental_expanded_uncertainty(u, coverage=...), 2.4 dB for the same 1.2 dB |
combine_linings, combine_subareas, combine_partial_exposures, combine_age_and_noise |
building.combined_lining_improvement, building.subarea_intensity_level, vibration.combined_daily_exposure, hearing.age_and_noise_threshold: a computation is named for what it returns |
air_attenuation_m |
environment.air_power_attenuation_per_m. The m it returns is the power attenuation coefficient of ISO 354, in 1/m, not a length |
attenuation_from_alpha, air_attenuation_coefficient |
materials.power_attenuation_from_alpha, the one conversion ISO 354 and ISO 17497-1 both make. Its argument is attenuation_db_per_m, where the two old functions named it alpha and pressure_attenuation_db_per_m. It refuses a NaN or an infinite alpha, which attenuation_from_alpha let through |
HtlanResult, NiptsResult |
hearing.HTLANResult, hearing.NIPTSResult: an acronym is written in capitals, as in HMLRatingResult |
AnpAircraft, AnpDatabase, AnpNpdCurves, AnpProfile, NpdLevelResult |
aircraft.ANPAircraft, aircraft.ANPDatabase, aircraft.ANPNPDCurves, aircraft.ANPProfile, aircraft.NPDLevelResult; the number of engines is ANPAircraft.n_engines |
HvacSpectrumResult |
noise_control.HVACSpectrumResult |
mic_calibration_factor, apply_mic_calibration |
materials.microphone_calibration_factor, materials.apply_microphone_calibration |
lab_airborne_insulation, lab_impact_insulation, LabAirborneInsulationResult, LabImpactInsulationResult, LabInsulationWarning |
building.laboratory_airborne_insulation, building.laboratory_impact_insulation, building.LaboratoryAirborneInsulationResult, building.LaboratoryImpactInsulationResult, building.LaboratoryInsulationWarning |
EnclosureResult |
noise_control.EnclosureInsertionLossResult, what enclosure_insertion_loss returns, beside EnclosureInsulationResult |
maximum_repeatability_standard_deviation, minimum_cumulative_duration_hours, minimum_phase |
building.max_repeatability_standard_deviation, hearing.min_cumulative_duration_hours, signals.min_phase: max and min in every public name |
rigid_mass_calibration_check |
vibration.verify_rigid_mass_calibration, with the same arguments and the same RigidMassCalibrationResult: it judges a measuring chain, so its verb is verify_ |
satisfies_lower_requirement, satisfies_upper_requirement |
building.assess_requirement_conformity(rating, expanded_uncertainty_db, required_rating, bound="minimum") or bound="maximum". The bool is its .passes, beside the .margin_db it was read from, and both formulae stay strict |
strong_coupling_satisfied |
building.check_strong_coupling, with the same arguments. The boolean array is its .holds, and .passes is every band |
tonal_seeking_survey |
environment.assess_tonal_survey(levels, frequencies=frequencies). The boolean array is its .prominent, beside the .min_level_differences and .level_differences it was read from |
air_density_astm, speed_of_sound_astm |
materials.air_density_astm_e2611, materials.speed_of_sound_astm_e2611, beside air_density_iso10534: a standard's designation in a name is written one way |
sae_band_attenuation |
aircraft.band_attenuation_arp5534, the document it follows |
itu_r_468_weighting |
electroacoustics.weighting_bs468 |
What did not change #
Most numbers. Every rename above returns what its predecessor returned, except where this section says otherwise, and if any other result moves after you finish the upgrade, that is a defect and it is worth reporting. The numbers that did move are below. Each moved because 3.3.0 disagreed with the document it follows, or because a default changed.
verify_filter_class grades every requirement of IEC 61260-1 at the bank's
input rate, not the Table 1 mask alone, and a band of a decimated bank moves by
up to 0.07 dB on white noise: the section on filter classes above says how.
| What moved | 3.3.0 | 4.0 |
|---|---|---|
Every curve, A, B, C, D, G and AU, through WeightingFilter.filter and filters.weighting_filter, which are now designed at the input rate instead of oversampled, and so every level that weights a signal through them, signals.laeq among them |
A at 48 kHz: −2.60 dB, −7.03 dB and −10.15 dB at the 10, 16 and 20 kHz rows of IEC 61672-1 Table 3; at 16 kHz, A −13.1 dB and C −16.7 dB at the 8 kHz row; at 32 kHz, B −23.9 dB, D −17.1 dB and AU −35.9 dB at 16 kHz | −2.49 dB, −6.60 dB and −9.32 dB, the design goals within 0.02 dB; −1.11 dB and −3.01 dB at the 8 kHz row; B −8.42 dB, D −0.69 dB and AU −19.61 dB, again the design goals |
WeightingFilter(..., stateful=True), which in 3.3.0 ran A as the plain bilinear design and G with sections designed for an oversampled rate, both at the input rate, and runs the accurate design now |
A at 48 kHz: −7.05 dB at the 12.5 kHz row; G at its own 10 Hz reference: −26.3 dB at 8 kHz and −36.3 dB at 1 kHz | −4.32 dB, the design goal; 0 dB at every rate |
verify_weighting_class |
graded the designed sections, and gave class 1 to an A weighting at 16 kHz that lost 12 dB at the 8 kHz row | grades the path a signal takes through WeightingFilter.filter |
itu_r_468_weighting, now electroacoustics.weighting_bs468 |
ITU-R BS.468-4 Table 1 interpolated between its rows: 4.45 dB at 11.06 kHz | the curve of the network the Recommendation prints: 5.06 dB there, and at most about 0.05 dB from Table 1 at its rows |
sae_band_attenuation, now aircraft.band_attenuation_arp5534 |
the saturation vapour pressure of ISO 9613-1 | the one SAE ARP 5534 prints: about 0.01 dB less over 1 km at 8 kHz and 10 kHz |
extended_tube_chamber with an inlet or outlet extension |
the straight section between the two side branches taken over the whole chamber length L | over L − L_a − L_b, which reproduces Bies Figure 8.20: for L = 0.5 m, an area ratio m = 16 and extensions of 0.125 m and 0.25 m, 22.7 dB at 200 Hz where it was 0.6 dB |
underwater.ray_trace and environment.atmospheric_ray_paths at a reflection |
a whole step taken through the boundary and folded back | a sub-step that ends on the boundary, so a ray that bounces lands elsewhere: one ray of a 100 m channel ends 5 km out at 9.4 m depth, where it ended at 0.3 m |
room.open_plan_metrics where the STI never falls to the threshold |
a distraction or privacy distance of 10¹⁵ m or more | NaN |
effective_kappa and thermal_boundary_layer_thickness left at their default air |
the five values ISO 9053-2 Annex A.3 prints | the air of IEC 61094-2 at the same state, which moves the correction in its fifth figure, as the section on fluid= says |
| a value that lands exactly on a limit a standard prints | judged by the last bits of its floating-point value | settled to nine decimal places first, the same on every machine |
The ISO 3382 fiche of a one-third-octave analysis takes its single-number
reverberation time over the six bands from 400 Hz to 1250 Hz, as clause 9.1
prints, where it averaged the 500 Hz and 1 kHz bands. The ISO 10846 fiche of
an indirect determination boxes the stiffness at the lowest line ISO 10846-3
Inequality (2) admits, with a transmissibility of 0.1 or less, where it boxed
the lowest line of the sweep, inside the resonance region. The microphone fiche
writes dB(468) for the ITU-R BS.468-4 weighting, which 3.3.0 let you label
CCIR. A plot draws a band with no reading as no bar, where it drew a measured
zero. Two more are in the sections above: installed_dynamic_stiffness below
100 kPa·s/m², and the ISO 3746 survey positions of
emission.measurement_positions.
For code written against 4.0.0rc1, the Signal contract is the one it was,
now kept in two more places, the blocks of read_blocks and the waveforms
inside five results. Every other formula is untouched. 4.0 rearranged the
furniture and put the unit on the label; apart from what this section lists, it
did not recompute anything.