2D FDTD wave simulation #
Most of phonometry predicts a number: a level, a reverberation time, a
transmission loss. The simulation domain computes the wave field
itself: fdtd_simulation integrates the linear acoustic equations on a 2D
grid with the finite-difference time-domain (FDTD) method, so reflection,
diffraction, interference, refraction through inhomogeneous media and modal
behaviour all emerge from first principles instead of being modelled term by
term. The implementation follows the reference formulation for outdoor sound
of Attenborough & Van Renterghem, Predicting Outdoor Sound (2nd ed., CRC
Press 2021), chapter 4: the staggered-in-place, staggered-in-time
pressure-velocity scheme (Eqs. 4.11-4.12), the Courant stability condition
(Eqs. 4.13-4.14), rigid boundaries as zero normal face velocity (Eq. 4.32)
and the frequency-independent real-impedance boundary (Eqs. 4.33-4.35).
The solver is deterministic by design: no random numbers and every operation in a fixed order, so on NumPy in float64 the same inputs produce bit-identical outputs on the same platform, and on CuPy the fields come out bit-identical to NumPy's on the GPU they were measured on. It is the engine behind the FDTD animations of this documentation, promoted to a public API with sources, pressure probes, rasterised obstacles, per-side boundary conditions and a frozen result object.
Here is one of those animations, and it is a fair advertisement for what the
rest of this page builds. Nothing in it is drawn: the colonnade is a boolean
obstacle_mask of rasterised circles and the wavefront is a single one-way
plane-wave packet with a Gaussian envelope one wavelength wide, launched at
$x = 0.30$ m into a 4 m × 1 m rigid-walled hall whose two ends absorb through
sponges hidden outside the frame. The carrier is 800 Hz, so the wavelength is
42.9 cm and the 10 to 17 cm columns are roughly a quarter to two fifths of it:
the regime in which a rigid cylinder both casts a readable shadow and
re-radiates strongly, which is why the coda that fills the hall is structured
rather than noise. That coda is deterministic multiple scattering: it is what
a diffuse field looks like before any statistical assumption is made about
it. The mesh is the worked example of the rule
section 4 derives: the tightest gap in
this layout is 6.6 cm between a column and a wall, so
$\Delta x = \min(\text{smallest aperture}/4,\ \lambda/8)$ allows up to 1.6 cm,
and the clip runs at 2.5 mm because a banner needs the definition.
Watch the high-resolution video (WebM)
1. The scheme: a wave equation on a grid #
In a non-moving medium the linearised equations of fluid dynamics reduce to a first-order system in the acoustic pressure $p$ and particle velocity $\mathbf{v}$ (Attenborough & Van Renterghem Eqs. 4.3-4.4):
$$ \frac{\partial p}{\partial t} + \rho c^2,\nabla!\cdot!\mathbf{v} = 0, \qquad \frac{\partial \mathbf{v}}{\partial t} + \frac{1}{\rho},\nabla p = 0 . $$
FDTD discretises both on a staggered grid (the acoustic analogue of the Yee cell): pressure lives at cell centres and each velocity component on the cell faces, half a cell away, and the two fields leapfrog in time, half a time step apart (Eqs. 4.11-4.12). Evaluating each spatial gradient exactly where the other field needs it gives a fourfold accuracy gain over a collocated grid (Eq. 4.9 vs 4.10) and allows in-place updates. Because only interior faces are stored, the domain edge is a perfectly rigid wall (zero normal velocity, Eq. 4.32) unless another boundary is requested.
The explicit scheme is stable only while a wavefront crosses at most one cell per time step. With square cells the Courant number (Eq. 4.13) is
$$ \mathrm{CN} = c,\Delta t\sqrt{\frac{1}{\Delta x^2} + \frac{1}{\Delta y^2}} = \frac{c,\Delta t,\sqrt{2}}{\Delta x} \le 1, $$
and the run, FDTDRun, derives the time step when it is built, from the
cfl parameter (the Courant number, default 0.6) and the largest sound speed
in the map; values outside $(0, 1)$ are rejected because the scheme is
unconditionally meaningless beyond the bound (Eq. 4.14).
A simulation is one record:
FDTDRun(c=..., dx=..., duration_s=..., sources=..., ...) takes every field
by name, holds the domain, its sources and what it records, and checks every
argument when it is built, so a mistake raises where the run is written;
fdtd_simulation(run) steps it, and compute= says where.
from phonometry import simulation
# A 3.0 x 2.0 m air domain: 300 x 200 cells of 1 cm.
run = simulation.FDTDRun(
c=343.0, dx=0.01, duration_s=2.0e-3, shape=(200, 300),
sources=[simulation.GaussianPulse(ix=60, iy=100, half_width_s=3.0e-4)],
recording=simulation.FDTDRecording(probes=[(200, 100)]),
)
res = simulation.fdtd_simulation(run)
print(res.size) # (3.0, 2.0) metres
print(round(res.dt * 1e6, 2)) # 12.37 microseconds (CN = 0.6)
print(res.provenance.device, res.provenance.dtype) # cpu float64
res.plot() # probe pressure histories (figure in §3)
The run stepped on NumPy in float64, and res.provenance records that. The
same call steps on an NVIDIA GPU through CuPy, or on PyTorch, with one more
argument; Where a simulation runs covers the devices, what each
needs installed, how a whole script picks one and what is promised about the
numbers on each.
on_gpu = simulation.fdtd_simulation(run, compute=simulation.Compute(device="cupy"))
print(on_gpu.provenance.device, on_gpu.provenance.gpu) # cupy, and the card's name
With a host the same run goes to another machine: see
Sending a simulation to a remote node.
Where heavy work runs maps the devices, the nodes and
the encoders in one place.
The grid is index-based: cell (ix, iy) has its centre at
((ix + 0.5) * dx, (iy + 0.5) * dx) metres, with rows plotted downward
(the imshow convention), so a position in metres maps to
ix = round(x / dx - 0.5).
2. Sources, probes, obstacles and boundaries #
Three source types inject a soft source (an additive pressure
contribution that does not scatter passing waves) at a grid cell:
GaussianPulse (a broadband pulse of temporal half-width half_width_s),
CWSource (a sine tone faded in with a raised-cosine ramp so its onset does
not splash a broadband transient) and SignalSource (an arbitrary sampled
waveform, linearly interpolated onto the simulation time steps). Probes
record the pressure at their cell every time step into the result. The
probes and the snapshot cadence travel together as one FDTDRecording,
passed as recording=; a run without one keeps only its time axis.
Plane waves "from infinity". Point sources in 2D are really line sources, so a diffuser or a barrier is often better interrogated with a plane wavefront. Two tools cover it, each one-way through its own mechanism:
sim.add_plane_wave(direction, center_m=..., half_width_m=..., wavelength_m=...)superimposes a Gaussian packet (optionally carrying a sine) as an initial condition travelling toward"down","up","left"or"right"; the leapfrog-consistent velocity written half a step back is what makes it one-way, and behind the front the residual energy is at numerical noise level. This is what the QRD diffusion animation uses.PlaneWaveSource(direction=..., waveform=..., offset=...)registered throughadd_source()injects a sustained plane wave on a line of cells: the incident pressure and the adjacent face velocity are driven together, so the launched field is transversely plane to machine precision and anything scattered back crosses the line untouched; with a sponge configured behind the line it is then absorbed (about -38 dB residual for a CW in the set-up above; the figure depends on the sponge).
from phonometry.simulation import FDTD2D, CWSource, PlaneWaveSource
sim = FDTD2D(343.0, 0.01, shape=(160, 80), absorbing_layer_cells=20,
absorbing_sides=("top", "bottom"))
tone = CWSource(ix=0, iy=0, frequency=1000.0) # reused as a waveform
sim.add_source(PlaneWaveSource(direction="down", waveform=tone.value, offset=22))
# or, for a single packet: sim.add_plane_wave("down", center_m=0.4,
# half_width_m=0.08, wavelength_m=0.34)
Geometry is rasterised: obstacle_mask marks rigid cells, and every
face touching a masked cell is closed (Eq. 4.32 again), so walls, barriers
and scatterers of any shape are just boolean arrays. Each domain side can
carry its own boundary condition, which a run takes as one FDTDBoundaries
record: sides= gives one condition to all four sides or maps each side to
its own, and absorbing_layer_cells= sets the thickness of the sponge:
"rigid"(default): a perfect reflector, $R = +1$."absorbing": a sponge layer ofabsorbing_layer_cellscells whose absorption rate ramps quadratically, emulating an open boundary (the simple precursor of the perfectly matched layers of section 4.2.3).- a real specific impedance $Z$ in Pa·s/m (a scalar or one value per edge cell): the locally reacting boundary of Eqs. 4.33-4.35, updated implicitly, with the normal-incidence reflection coefficient $R = (Z - \rho c)/(Z + \rho c)$; $Z = \rho c$ is anechoic.
Two limits of that machinery are worth naming. Interior geometry is rigid by
construction: only the four domain sides accept an impedance or a sponge, so
an interior surface can be softened only by backing it with a lossy damping
region. That region is a frequency-independent equivalent fluid rather
than a porous model. The governing equations assume a non-moving medium:
wind or flow advection is not modelled, and the only impedance boundary is
the frequency-independent real one of Eqs. 4.33-4.35.
The stepping engine FDTD2D is public too: it exposes step(), run(),
the field arrays and the energy, for callers that need frame-by-frame access
(the documentation animations use it directly). A plane pulse launched down
a duct against an impedance edge reproduces the textbook reflection
coefficient:
import numpy as np
from phonometry import simulation
rho, c, dx = 1.2, 343.0, 0.01
sim = simulation.FDTD2D(c, dx, rho=rho, shape=(3, 1200),
edge_impedance={"right": 3.0 * rho * c})
x = (np.arange(1200) + 0.5) * dx
sim.p[:] = np.exp(-(((x - 6.0) / 0.15) ** 2))[None, :] # plane pulse
trace = []
for _ in range(int(round(0.032 / sim.dt))):
sim.step()
trace.append(sim.p[1, 900])
trace = np.asarray(trace)
t = (np.arange(trace.size) + 1) * sim.dt
t_return = 6.0 / c + 3.0 / c # via the wall, back to x = 9 m
incident = trace[t < t_return - 0.001].max()
echo = trace[t > t_return]
print(round(float(echo[np.abs(echo).argmax()] / incident), 2)) # 0.5
# (Z - rho c)/(Z + rho c) = (3 - 1)/(3 + 1) = +0.5
Before spending a single time step, sim.plot_geometry() draws the
configured domain: edges, sponges, obstacles, sources and the probes you
intend to record, given as the (ix, iy) cells an FDTDRecording takes and
refused in the words a run uses when one is off the grid or inside an
obstacle. Catching a sponge on the wrong side or a probe in the
wrong place costs seconds here and a full re-run later.
Everything the run will see, before it runs: the sponge layers eat the left and right boundaries, the top edge carries the anechoic $\rho c$ impedance, the untreated bottom stays rigid, and both probes sit clear of the obstacle and the sponges.
Show the code for this figure
import numpy as np
import matplotlib.pyplot as plt
from phonometry import simulation
mask = np.zeros((60, 90), dtype=bool)
mask[25:35, 40:44] = True
sim = simulation.FDTD2D(343.0, 0.05, shape=(60, 90), absorbing_layer_cells=8,
absorbing_sides=("left", "right"),
edge_impedance={"top": 413.0}, obstacle_mask=mask)
sim.add_source(simulation.GaussianPulse(ix=10, iy=30, half_width_s=1e-3))
# Check the domain before running it: nothing has been stepped yet.
# The probes are the (ix, iy) cells an FDTDRecording takes, drawn at their centres.
sim.plot_geometry(probes=[(59, 29), (79, 39)])
plt.show()
A three-row rigid-walled domain is a plane-wave tube, and with the per-cell
damping map a porous sample becomes an equivalent fluid, which turns the
solver itself into a measurable specimen: the
impedance-tube guide runs the ISO 10534-2 and
ASTM E2611 measurements virtually on exactly that domain, animations
included, and recovers the analytic absorption and transmission loss of the
modelled sample through the library's own reduction chains (the
tests/simulation cross-checks run this on every commit).
2b. From the near field to the far field #
A polar response or a diffusion coefficient is a far-field quantity, but an
FDTD box ends a couple of wavelengths from the scatterer. The
add_contour_probe / far_field_from_contour pair bridges that gap with
the 2D Kirchhoff-Helmholtz integral: the probe folds the steady-state
pressure and outward normal velocity on a closed rectangle of cell faces
into running DFT sums (an on-the-fly DFT per point and frequency, so a
continuous-wave run stores no time histories), and the integral propagates
those phasors to infinity with the free-space Green function
$-(j/4),H_0^{(2)}(kR)$: the same construction full-wave FEM solvers use to
report scattering patterns from near-field data. Two properties carry the
scheme: the staggered grid already holds $v_n$ exactly on the contour
faces, and any field whose sources lie outside the contour integrates to
nothing (extinction), so the total-field phasors of a plane-wave scattering
run transform directly into the scattered far field. In the discrete
solver that cancellation leaves a grid-dispersion residual (below 0.01 dB
on the scenes validated here); ContourPhasors.subtract() removes it with
a no-scatterer reference run when that last fraction matters.
import numpy as np
from phonometry import simulation
c0, dx, f0 = 343.0, 0.005, 2000.0
sim = simulation.FDTD2D(c0, dx, shape=(300, 300), absorbing_layer_cells=40)
sim.add_source(simulation.CWSource(ix=150, iy=150, frequency=f0))
probe = sim.add_contour_probe(90, 210, 90, 210, frequencies=[f0])
sim.run(round(4.5e-3 / sim.dt)) # run the transient out
probe.reset() # then integrate the DFT window
sim.run(round(10.0 / f0 / sim.dt))
pattern = simulation.far_field_from_contour(
probe.phasors(f0), np.arange(0.0, 360.0, 5.0),
origin=(150.5 * dx, 150.5 * dx))
levels = 20 * np.log10(np.abs(pattern))
print(round(float(levels.max() - levels.min()), 2)) # 0.04 dB of ripple:
# a line source is omnidirectional, and its level matches the 2D
# free-space Green function to 0.11 dB
The analytic oracles behind those numbers run on every commit
(tests/simulation): the reconstructed monopole pattern is flat within
0.05 dB and sits on the 2D Green-function level within 0.11 dB, an
antiphase pair reproduces the two-source array factor within 0.4 % of the
peak, and a contour that does not enclose the source transforms to less
than 1 % of one that does. On top of them sit two meshed-panel
cross-checks at 2 kHz: a quadratic-residue diffuser with wells to 27.4 cm,
whose NTFF polar response tracks the Fraunhofer prediction of
predict_diffuser_polar_response (pattern correlation 0.94, ISO
17497-2 directional diffusion coefficient within 0.08), and the deep
subwavelength metadiffuser below.
The far-field chain is what finally closes the metadiffuser loop end to
end: the Table-1 panel of the paper (every slit, neck and cavity meshed
at 0.5 mm) is driven to steady state by a plane wave, captured on a contour,
and transformed against the metadiffuser_polar_response model (TMM +
Fraunhofer) of the materials module. That is the library-side counterpart
of the TMM-vs-FEM comparison the metadiffuser paper itself reports, small
discrepancies included: the transfer-matrix model homogenises each 7 cm
cell into one locally reacting reflection coefficient and ignores the
evanescent coupling between neighbouring mouths, so the lobe structure
agrees while individual nulls shift by a few degrees.
Two independent routes to the same far field: the meshed panel in a full-wave time-domain solver (solid) against the homogenised transfer-matrix chain (dashed). The lobes agree; the nulls, sensitive to the millimetre end corrections the TMM models analytically, shift by a few degrees.
Show the code for this figure
import numpy as np
import matplotlib.pyplot as plt
from phonometry import materials, simulation
c0, dx, f0, pitch = 343.0, 0.0005, 2000.0, 0.07
rows = [(14.7, 13.0, 16.4, 6.2, 9.0), (30.9, 9.1, 4.3, 3.5, 9.0),
(30.9, 9.1, 4.3, 3.5, 9.0), (15.7, 13.3, 17.0, 6.3, 9.0),
(20.3, 18.0, 20.7, 3.2, 9.0)] # Table 1: h, l_n, l_c, w_n, w_c
# Mesh the real panel: a rigid slab with the slits, necks and cavities
# carved out at 0.5 mm (the 3.2 mm narrowest neck spans six cells).
sponge, gap, marg, front = 60, 60, 20, 40
face = round(5 * pitch / dx)
lat = marg + gap + sponge
r_face = sponge + gap + front
slab = round(0.023 / dx) # 2 cm panel + 3 mm back wall
mask = np.zeros((r_face + slab + marg + gap + sponge,
face + 2 * lat), dtype=bool)
mask[r_face:r_face + slab, lat:lat + face] = True
for n, (h, ln, lc, wn, wc) in enumerate(rows):
xs = (n + 0.12) * pitch
c0s, c1s = lat + round(xs / dx), lat + round((xs + h * 1e-3) / dx)
mask[r_face:r_face + round(0.02 / dx), c0s:c1s] = False
for m in range(2): # two resonators per slit
ym, xn = (m + 0.5) * 0.01, xs + h * 1e-3
r0 = r_face + round((ym - 0.5e-3 * wn) / dx)
r1 = r_face + round((ym + 0.5e-3 * wn) / dx)
mask[r0:r1, c1s:lat + round((xn + ln * 1e-3) / dx)] = False
r0 = r_face + round((ym - 0.5e-3 * wc) / dx)
r1 = r_face + round((ym + 0.5e-3 * wc) / dx)
mask[r0:r1, lat + round((xn + ln * 1e-3) / dx):
lat + round((xn + (ln + lc) * 1e-3) / dx)] = False
sim = simulation.FDTD2D(c0, dx, shape=mask.shape, absorbing_layer_cells=sponge,
cfl=0.9, obstacle_mask=mask) # 340 cells/lambda:
sim.add_source(simulation.PlaneWaveSource( # dispersion negligible
direction="down", waveform=simulation.CWSource(ix=0, iy=0, frequency=f0).value, offset=sponge))
probe = sim.add_contour_probe(lat - marg, lat + face + marg - 1,
r_face - front, r_face + slab + marg - 1,
frequencies=[f0])
sim.run(round(8e-3 / sim.dt)) # transient (ramp + ring-up) out
probe.reset()
sim.run(round(10.0 / f0 / sim.dt)) # a 10-period_m DFT window (in steps)
angles_deg = np.arange(-90.0, 90.1, 5.0) # from the panel normal
pattern = simulation.far_field_from_contour(
probe.phasors(f0), angles_deg - 90.0, # the normal points along -y
origin=((lat + face / 2.0) * dx, r_face * dx))
levels = 20 * np.log10(np.abs(pattern) / np.abs(pattern).max())
wells = [materials.MetadiffuserWell(slit_height_m=h * 1e-3,
resonators=(materials.HelmholtzResonator(neck_length_m=ln * 1e-3, neck_side_m=wn * 1e-3,
cavity_length_m=lc * 1e-3, cavity_side_m=wc * 1e-3),) * 2)
for h, ln, lc, wn, wc in rows]
model = materials.metadiffuser_polar_response(f0, wells, depth_m=0.02, period_m=pitch,
angles_deg=angles_deg, n_repetitions=1)
ax = model.plot(color="#1f77b4", marker="", linestyle="--",
label="TMM + Fraunhofer model")
ax.plot(np.radians(angles_deg), levels, color="#d62728", lw=2.2,
label="FDTD + NTFF, panel meshed at 0.5 mm")
ax.set_ylim(-40.0, 2.0)
ax.legend(loc="lower center")
plt.show()
3. When to use it, and the 2D limits #
FDTD earns its cost when the geometry drives the physics: diffraction around a barrier or through an opening, interference of direct and reflected paths, scattering from obstacles, modal behaviour of odd-shaped enclosures, refraction through a sound-speed gradient. One run captures all frequencies at once (a pulse excites the whole band; one FFT of a probe yields the spectrum), where a frequency-domain method needs one solve per frequency.
Show the code for this figure
import numpy as np
import matplotlib.pyplot as plt
from phonometry import simulation
# A 3.0 x 2.0 m free field (absorbing edges) with a thin rigid barrier:
# probe A sees the direct pulse plus the barrier reflection, probe B sits
# in the shadow and only receives the wave diffracted around the edge.
mask = np.zeros((200, 300), dtype=bool)
mask[60:, 150:154] = True
run = simulation.FDTDRun(
c=343.0, dx=0.01, duration_s=9.0e-3, shape=(200, 300),
sources=[simulation.GaussianPulse(ix=60, iy=100, half_width_s=3.0e-4)],
recording=simulation.FDTDRecording(
probes=[(100, 100), (240, 100)], snapshot_every=75),
obstacle_mask=mask,
boundaries=simulation.FDTDBoundaries(
sides="absorbing", absorbing_layer_cells=30),
)
res = simulation.fdtd_simulation(run)
fig, (ax_f, ax_p) = plt.subplots(
1, 2, figsize=(12.5, 5.0), gridspec_kw={"width_ratios": [1.25, 1.0]})
res.plot(kind="snapshot", frame=7, ax=ax_f)
res.plot(ax=ax_p)
plt.tight_layout()
plt.show()
Conversely, when a validated closed form exists (statistical reverberation, ISO 9613-2 outdoor attenuation, image sources in a rectangular room) the closed form is thousands of times cheaper: this solver is the cross-check and the demonstrator, not the replacement. The oracle works both ways; a rigid-box run reproduces the analytic room modes:
import numpy as np
from phonometry import simulation
lx, ly, dx = 1.0, 0.7, 0.02
nx, ny = round(lx / dx), round(ly / dx)
run = simulation.FDTDRun(
c=343.0, dx=dx, duration_s=0.35, shape=(ny, nx),
sources=[simulation.GaussianPulse(ix=7, iy=5, half_width_s=2.0e-4)],
recording=simulation.FDTDRecording(probes=[(nx - 4, ny - 3)]),
)
res = simulation.fdtd_simulation(run)
p = res.pressures[0]
spec = np.abs(np.fft.rfft(p * np.hanning(p.size), n=8 * p.size))
freqs = np.fft.rfftfreq(8 * p.size, res.dt)
sel = (freqs > 250) & (freqs < 350)
print(round(0.5 * 343.0 * float(np.hypot(1 / lx, 1 / ly)), 1)) # 299.1 exact (1,1) mode
print(round(float(freqs[sel][np.argmax(spec[sel])]), 1)) # 298.9 measured
The probe spectrum of the rigid-box run peaks exactly on the analytic mode frequencies $f = (c/2)\sqrt{(n_x/L_x)^2 + (n_y/L_y)^2}$ (Kuttruff 6e, Ch. 3). The barely visible leftward offset of the highest peaks is the numerical dispersion of the accuracy section below: short wavelengths propagate slightly slow on the grid, so the modelled resonances under-read by a fraction of a percent.
Show the code for this figure
import numpy as np
import matplotlib.pyplot as plt
from phonometry import simulation
lx, ly, dx, c = 1.0, 0.7, 0.02, 343.0
nx, ny = round(lx / dx), round(ly / dx)
run = simulation.FDTDRun(
c=c, dx=dx, duration_s=0.35, shape=(ny, nx),
sources=[simulation.GaussianPulse(ix=7, iy=5, half_width_s=2.0e-4)],
recording=simulation.FDTDRecording(probes=[(nx - 4, ny - 3)]),
)
res = simulation.fdtd_simulation(run)
# One line: the raw probe pressure history the spectrum is computed from.
res.plot()
plt.show()
# The mode check: probe spectrum against the analytic rigid-room modes.
p = res.pressures[0]
spec = np.abs(np.fft.rfft(p * np.hanning(p.size), n=8 * p.size))
freqs = np.fft.rfftfreq(8 * p.size, res.dt)
sel = (freqs >= 100) & (freqs <= 450)
fig, ax = plt.subplots()
ax.plot(freqs[sel], 20 * np.log10(spec[sel] / spec[sel].max()))
for mx, my in [(1, 0), (0, 1), (1, 1), (2, 0), (2, 1)]:
ax.axvline(0.5 * c * np.hypot(mx / lx, my / ly), ls=":", color="tab:red")
ax.set(xlabel="Frequency [Hz]", ylabel="Probe spectrum [dB re max]",
ylim=(-60, 6))
plt.show()
The domain is two-dimensional, and that changes the physics, not just the cost. A 2D point source is physically an infinite line source: its amplitude spreads cylindrically as $1/\sqrt{r}$ (3.0 dB per doubling of distance) instead of the spherical $1/r$ (6.0 dB) of a 3D point source, and the 2D impulse response trails a wake behind the wavefront instead of passing cleanly. Interference and diffraction patterns are faithful; absolute levels and decay rates are not those of a 3D room. Treat 2D runs as cross-sections and demonstrations, and validate any 3D-quantitative claim against a closed form or a 3D solver.
4. Numerical dispersion and accuracy #
The discrete grid propagates each frequency at a slightly wrong speed: short wavelengths lag, so a sharp pulse develops a ripple tail and resonances shift slightly. This numerical dispersion is the discrete counterpart of Eq. 4.15; on the axes of a square grid the scheme's dispersion relation is
$$ \sin!\left(\frac{\omega,\Delta t}{2}\right) = \frac{c,\Delta t}{\Delta x}, \sin!\left(\frac{k,\Delta x}{2}\right), $$
with a leading-order relative frequency error of magnitude
$(1 - S^2),(k,\Delta x)^2 / 24$ along the grid axes (the modelled frequency
under-reads, so the signed error is negative), where $S = c,\Delta t / \Delta x$;
the error is largest exactly on-axis and vanishes along the cell diagonal
at the Courant limit $\mathrm{CN} = 1$. The practical rule is to resolve at
least 10 cells per shortest wavelength, $\Delta x \le c_\text{min} / (10 f_\text{max})$
with the smallest sound speed of the domain: at exactly 10 cells the
small-Courant bound $(k,\Delta x)^2 / 24$ evaluates to about 1.6 %, reduced
by the $1 - S^2$ factor to about 1.4 % at the default cfl = 0.6
(in a heterogeneous domain the time step follows the fastest cells, so
slower regions run at a lower local Courant number and sit nearer the
1.6 % bound), and every finer-resolved or off-axis component is more
accurate. With $\Delta x = 1$ cm the 10-cell point in air sits at roughly
3.4 kHz, and halving $\Delta x$ quarters the error (the scheme is second
order, and the validation suite measures that observed order under grid
refinement).
That bound is a phase speed error. A pulse travels at the group speed, and differentiating the same dispersion relation gives $v_\mathrm{g}/c = \cos\theta/\sqrt{1 - S^2\sin^2\theta}$ with $\theta = k\Delta x/2$, i.e. $1 - (1 - S^2)(k,\Delta x)^2/8$: the same law with 8 in place of 24. A wavepacket thus arrives three times later than the phase rule suggests: 4.1 % at ten cells per wavelength, not 1.4 %. Being a speed error, it is paid per metre travelled. The clip runs one 500 Hz burst down three plane tubes that differ only in $\Delta x$ (137.2, 68.6 and 34.3 mm, i.e. 5, 10 and 20 cells per wavelength) with the exact continuous wave drawn behind each trace: the measured deficits are 17.2 %, 4.3 % and 1.1 % against 17.3 %, 4.3 % and 1.1 % from the closed form, and the three packets cross a 6.6 m finish line 3.3, 0.7 and 0.2 ms after the exact wave does.
Watch the high-resolution video (WebM)
The tests pin the solver to analytic oracles: box and duct eigenfrequencies, free-field arrival times and cylindrical decay, the rigid-wall image echo, the impedance reflection coefficient above and the dispersion relation itself.
The frozen FDTDResult carries the time axis, the per-probe pressure
histories, the probe positions in metres, the grid metadata, the sources,
the optional field snapshots with their times and decimation, the obstacle
mask and the provenance of the run; its .plot() draws the probe
histories, and .plot(kind="snapshot") renders one recorded field with the
geometry overlaid.
The same staggered lattice extends beyond fluids: the companion
elastic_fdtd_simulation integrates the P-SV velocity-stress system of
Virieux (1986) on the same grid, adding shear waves, stress-imaging free
surfaces with Rayleigh waves, and fluid-solid coupling with mode
conversion, Scholte interface waves and immersed-plate transmission. That
solver has its own guide,
Elastic waves and fluid-solid coupling.
Writing the run to a video #
The run record this guide builds goes to the video writer as it is:
simulation.write_fdtd_animation steps it and draws its pressure field into
a WebM, an MP4 or a GIF as it is computed, a frame every snapshot_every
steps, without storing the snapshots.
Writing animations and FDTD runs to video says how a
frame is drawn and its colour scale found, which encoder writes the file, and
how the same call steps on a GPU or goes to a node.
from phonometry import simulation
run = simulation.FDTDRun(
c=343.0, dx=0.01, duration_s=2e-3,
shape=(60, 80),
sources=[simulation.GaussianPulse(ix=40, iy=30, half_width_s=5e-5)],
recording=simulation.FDTDRecording(snapshot_every=10),
)
res = simulation.write_fdtd_animation(
"fdtd_pulse.webm", run, frame=simulation.AnimationFrame(size=(480, 360))
)
Quick answers #
How do I choose the FDTD grid spacing? #
Resolve at least 10 cells per shortest wavelength,
$\Delta x \le c_\text{min} / (10 f_\text{max})$, using the smallest sound
speed in the domain.
At exactly 10 cells the on-axis dispersion error bound is about 1.6 %,
reduced to about 1.4 % at the default cfl = 0.6, and halving $\Delta x$
quarters the error (the scheme is second order). With $\Delta x = 1$ cm the
10-cell point in air sits at roughly 3.4 kHz.
What Courant number keeps an FDTD simulation stable? #
The explicit scheme is stable only while a wavefront crosses at most one
cell per time step. With square cells the Courant number is
$\mathrm{CN} = c,\Delta t,\sqrt{2}/\Delta x \le 1$ (Attenborough & Van
Renterghem Eq. 4.13). FDTDRun derives the time step from its cfl
parameter (the Courant number, default 0.6) and the largest sound speed in
the map, and refuses a cfl outside $(0, 1)$ when it is built.
Can I trust the absolute levels from a 2D FDTD run? #
No. A 2D point source is physically an infinite line source: its amplitude spreads cylindrically as $1/\sqrt{r}$, 3.0 dB per doubling of distance, instead of the spherical $1/r$ (6.0 dB per doubling) of a 3D point source. Interference and diffraction patterns are faithful, but absolute levels and decay rates are not those of a 3D room; validate any 3D-quantitative claim against a closed form or a 3D solver.
See also #
- Elastic waves and fluid-solid coupling: the P-SV companion solver on the same staggered grid, with Rayleigh and Scholte waves, mode conversion and immersed plates.
- Where a simulation runs: the same run on an NVIDIA GPU through CuPy or on PyTorch, and what is promised about its numbers.
- Conformance report: two of the closed-form validation anchors of section 6 run there.
- API reference:
simulation.fdtd,simulation.ntff.
References #
- Attenborough, K., & Van Renterghem, T. (2021). Predicting outdoor sound (2nd ed.). CRC Press. doi:10.1201/9780429470806. Chapter 4: the pressure-velocity FDTD reference model implemented here, from the governing equations (4.3-4.4) and the staggered leapfrog update (4.11-4.12) through the Courant condition (4.13-4.14), the phase-error analysis (4.15) and the rigid and finite-impedance boundary conditions (4.32-4.35).
- Kuttruff, H. (2016). Room acoustics (6th ed.). CRC Press. doi:10.1201/9781315372150. Section 3.5 places time-domain wave-based methods among the numerical approaches to the wave equation in enclosures, and chapter 3 gives the rigid-room normal modes used as the analytic oracle.
- Williams, E. G. (1999). Fourier acoustics: Sound radiation and
nearfield acoustical holography. Academic Press.
doi:10.1016/B978-0-12-753960-7.X5000-1.
Chapter 8: the Helmholtz integral equation behind
far_field_from_contour, with the outgoing free-space Green function and the far-field limit of §2b. - Jiménez, N., Cox, T. J., Romero-García, V., & Groby, J.-P. (2017). Metadiffusers: Deep-subwavelength sound diffusers. Scientific Reports, 7, 5389. doi:10.1038/s41598-017-05710-5. The meshed Table-1 panel and the near-to-far-field polar comparison of §2b reproduce, with this solver, the TMM-vs-full-wave cross-check the paper reports.
Standards and sources #
The module implements a textbook numerical method rather than a measurement standard: the discretisation, stability bound and boundary conditions follow Attenborough & Van Renterghem (2021) chapter 4 as the citable reference formulation. Validation is anchored to closed forms (rigid-box eigenfrequencies, cylindrical spreading, image sources, the normal-incidence reflection coefficient and the scheme's dispersion relation); two of those anchors run in the conformance report. The elastic P-SV companion solver and its own oracles are covered in Elastic waves and fluid-solid coupling.