Naming #

This page governs every name phonometry gives: modules, classes, exceptions and warnings, functions, parameters and record fields, published and private constants, and the words, units and spelling those names are made of. Read it before you add or rename a public name, a parameter or a constant, and whenever a review cites an N rule. How a signature is shaped (order, keyword-only arguments, choices, returns) is on API shape, and how a test file is named is on Tests.

N1. Name a module for its subject in words, never for a standard's designation #

Why. A reader looks for a module by what it computes, and an edition can change without a rename, so the designation lives in the module docstring (D1). The subject fits in at most four words, as every public module's does. A reference page titled tonality (ECMA-418-2) ranked almost level with the guides written to that standard in the site search.

Do

src/phonometry/hearing/noise_induced_hearing_loss.py
src/phonometry/emission/sound_power.py

Don't

src/phonometry/hearing/iso1999.py

Enforced by: tests/test_api_docs_generator.py::test_no_page_title_carries_a_number, review

Exceptions. Private fiche modules under src/phonometry/_report/ are named for the standard their fiche implements (iso717.py) and are not held to it. The reference page of a private module is titled by its domain and subject in words (signals: correlation) and says which package its names are imported from.

N2. Make a module private when a function of its package takes its name #

Why. signals/correlation.py sat beside signals.correlation(), so import phonometry.signals.correlation bound the function, signals.correlation.time_delay raised AttributeError, and the API reference still had a page at that address. Thirty-one modules were hidden this way. The private module follows PEP 8, numpy._core and SciPy since 1.8: its names are reached through the package (signals.time_delay).

Do

src/phonometry/signals/_correlation.py, its names reached as phonometry.signals.<name>

Don't

src/phonometry/signals/correlation.py beside the published function signals.correlation

Enforced by: scripts/check_api_reference.py, tests/test_removed_names.py::test_a_module_hidden_behind_its_function_is_private, CI: Curated API quick table covers __all__

N3. Give every top-level name a module keeps for itself a leading underscore #

Why. A bare name reads as public to every reader and every tool, ends up in a guide or a script through the full module path, and then cannot be renamed without breaking it. What the module does publish is listed in its __all__ (A2).

Do

_OCTAVE_BANDS = (125.0, 250.0, 500.0, 1000.0)


def _warn_above_plane_wave_limit(frequency: float) -> None: ...

Don't

OCTAVE_BANDS = (125.0, 250.0, 500.0, 1000.0)  # read by this module only, missing from __all__

Enforced by: scripts/check_api_reference.py, CI: Curated API quick table covers __all__

Exceptions. Typing constructs (a type alias, a TypeVar, a Protocol) stay PascalCase, unlisted and unprefixed. A rare public-looking name may go in UNLISTED_EXEMPTIONS of scripts/check_api_reference.py, keyed by location with its reason.

N4. Name a result class <Concept>Result for what its function returns #

Why. One suffix tells a caller which class a function returns. EnclosureResult was what enclosure_insertion_loss returned, beside EnclosureInsulationResult, and the two names did not say which was which.

Do

from phonometry import noise_control

noise_control.EnclosureInsertionLossResult

Don't

class EnclosureResult: ...  # returned by enclosure_insertion_loss

Enforced by: review

Exceptions. The psychoacoustic <Method><Metric> family is sanctioned (ZwickerLoudness, EcmaLoudness), and value and input objects take a plain name (Quantity, Fluid). A verdict record takes its family's noun, as the existing verdicts do: a check_ returns a <Concept>Check, a verify_ a <Concept>Verification or a compliance <Concept>Result, an assess_ a <Concept>Assessment.

N5. Write an acronym in capitals in a class name #

Why. HtlanResult, AnpAircraft and DbHrCheck sat beside STIResult, EPNLResult and ZoomFFTResult, so a caller had to remember which spelling each class used.

Do

from phonometry import aircraft, hearing

aircraft.ANPAircraft, hearing.HTLANResult

Don't

class HtlanResult: ...
class AnpAircraft: ...

Enforced by: tests/test_public_vocabulary.py::test_an_acronym_is_written_in_capitals

Exceptions. Ecma keeps its spelling (EcmaLoudness): Ecma International spells its own name so, and it is not an acronym (_PROPER_NAMES of the test). The acronyms are the curated _ACRONYMS of the test plus any run of capitals another public class writes. Ruff's N naming rules are not selected (they would rename the standards' symbols; only N812, on import aliases, is), so this test is the only enforcer.

N6. Name an exception <Topic>Error and a warning <Topic>Warning #

Why. fluids.FluidPropertyUnavailable was the one published exception without the suffix, beside CatalogueError; in an except clause a reader could not tell it from a value (PEP 8). A warning class named for its topic is what a filter names; the class it derives from is A49.

Do

from phonometry import fluids, io, room

io.CatalogueError, fluids.FluidPropertyUnavailableError, room.AuditoriumWarning

Don't

class FluidPropertyUnavailable(AttributeError): ...
class AuditoriumNotice(PhonometryWarning): ...

Enforced by: tests/test_package_architecture.py::test_every_published_exception_is_named_an_error, tests/test_package_architecture.py::test_every_published_warning_is_a_phonometry_warning

Exceptions. An exception subclasses the built-in it refines, so the except a caller already writes still catches it: CatalogueError(ValueError), and FluidPropertyUnavailableError(AttributeError), which keeps hasattr and getattr with a default working.

N7. Name a function for the quantity it returns; keep a verb for an action #

Why. combine_linings, combine_subareas and combine_age_and_noise returned numbers under verb names, and the same root-sum-square had three names in three packages.

Do

from phonometry import vibration

vibration.combined_daily_exposure

Don't

combine_partial_exposures(...)
get_daily_exposure(...)
calculate_daily_exposure(...)

Enforced by: review

Exceptions. A verb stays where the function acts (apply_weighting), merges objects (combine_fault_lines, combine_duct_paths) or judges (verify_, assess_, check_, see N9). No public name starts with get_, calculate_ or compute_. Where the bare noun would collide with another function or claim more than the function computes, it takes its family's prefix (silencer_sound_power_level).

N8. Leave _db and _hz off a function name; keep a unit where two compete #

Why. Thirty-five functions were named for the unit of their answer, and air_attenuation_m returned a coefficient in 1/m, not a length. The prefix of screen_background_corrected_level is N7's: a bare name that would collide takes its family's.

Do

from phonometry import noise_control

noise_control.screen_background_corrected_level

Don't

background_corrected_level_db(...)
air_attenuation_m(...)

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_every_public_function_is_named_for_what_it_returns

Exceptions. A unit stays where the quantity has more than one customary unit (peak_velocity_from_kb_mm_s, admissible_exposure_s, air_power_attenuation_per_m). A method that reads a printed row's columns, or returns a quantity the record also holds in another unit, goes in FUNCTION_UNIT_EXEMPT of the guard, keyed by (module, qualified name) with its reason (WindowMetricsResult.enbw_hz sits beside the enbw_bins its record holds).

N9. Name a judgment verify_ for an instrument, assess_ for a situation, check_ for a setup #

Why. The three verbs are not interchangeable: verify_weighting asks whether a meter's filter meets ISO 8041-1, check_source_positions whether a measurement had enough loudspeaker positions for its clause to apply; both may fail, and only the first is about equipment. What a judgment returns is A39.

Do

from phonometry import noise_control, vibration

vibration.verify_weighting  # an instrument: a meter's weighting filter
vibration.assess_building_vibration  # a situation: a measured peak velocity against its guideline value
noise_control.check_source_positions  # a setup: the positions the method needs

Don't

check_weighting(...)  # judges a meter's filter, an instrument
verify_source_positions(...)  # judges the measurement setup

Enforced by: tests/test_verdict_shape.py::test_every_judgement_is_named_with_its_verb, tests/test_verdict_shape.py::test_every_judging_method_is_named_with_its_verb, review

Exceptions. A predicate that only selects which procedure a clause applies answers no pass or fail, keeps its verb and returns a bool (low_frequency_procedure_applies, resolve_tones_separately, listed in REGIME_PREDICATES of the test with their reason). A method that tests membership or provenance, looks up one requirement of a verdict, or says how a value is reported goes in PREDICATE_METHODS, keyed by location with its reason. The tests prove that a judgment carries one of the three verbs; which verb fits is review.

N10. Never start a public function, class or module name with test or Test #

Why. pytest collects every function named test* and every class named Test* from a module a test file imports, so from phonometry.noise_control import * in a user's test file collected test_environment_applicability and failed on a fixture it never asked for. A module named test_*.py is collected from the repository root and reads as a test file in every listing: signals.test_signals held the library's test signals and nothing a test runs.

Do

from phonometry import noise_control, signals

noise_control.check_enclosure_test_environment
signals.noise_signal

Don't

test_environment_applicability(...)
from phonometry.signals.test_signals import noise_signal

Enforced by: tests/test_verdict_shape.py::test_no_public_name_is_collected_by_pytest, tests/test_verdict_shape.py::test_no_public_module_is_named_like_a_test_file, tests/test_removed_names.py::test_the_test_signal_module_is_private

Exceptions. Upper-case constants (TEST_REPORT_ITEMS, TEST_RUNS) are not collected by pytest and are not held to it, nor is a field or a method of a class whose name does not start with Test (Provenance.test_standard_of). A private module may hold test signals (signals._test_signals); its functions keep their package address.

N11. Name a catalogue lookup <x>_named after its PUBLISHED_<X>, and take catalogue= #

Why. duct_wall_named searched the duct transmission loss catalogue, so its name did not say which table it read; and a lookup that searches only the published table cannot search the caller's own catalogue, read from a file or joined with the published one by |.

Do

from phonometry import materials

materials.porous_materials_named, materials.PUBLISHED_POROUS_MATERIALS

Don't

duct_wall_named(...)
PUBLISHED_AIR

Enforced by: tests/io/test_catalogue_lookups.py::test_a_lookup_is_named_after_the_catalogue_it_searches, tests/io/test_catalogue_lookups.py::test_every_lookup_the_packages_publish_takes_a_catalogue, tests/io/test_catalogue_lookups.py::test_the_table_here_lists_every_lookup_the_packages_publish

Exceptions. PUBLISHED_ names a mapping of rows only; a single published object is named for its role (ABSORBER_AIR, SIMULATION_AIR). A lookup answers every match as a tuple, in the order the mapping holds them, and never picks one. A new lookup is added to LOOKUPS in the test.

N12. Name each concept with the one word the library already uses for it #

Why. A sample rate was fs in 165 places and fs_hz or sample_rate_hz in the newest modules, and a band axis went by six names, so code written against one module had to be relearned for the next. The vocabulary: fs, x, frequencies, levels, times, distances, speeds_of_sound, volume, coverage for a coverage probability, confidence for an interval, weighting, fraction, energy_fraction.

Do

import numpy as np
from phonometry import filters

fs = 48000
x = np.zeros(fs)
result = filters.octave_filter(x, fs)
bands = result.frequencies

Don't

result = filters.octave_filter(signal, sample_rate_hz)
bands = result.band_centers

Enforced by: tests/test_public_vocabulary.py::test_one_concept_is_spelled_one_way, tests/test_public_vocabulary.py::test_every_kept_minority_spelling_still_exists

Exceptions. The retired spellings are the _MINORITY table of the test (sample_rate and fs_hz for fs; freqs and band_centers for frequencies; sound_speed for speed_of_sound; passed for passes; band_type for fraction; curve for weighting; and more). A minority spelling is kept only in _MINORITY_EXEMPT, keyed by location with its reason, and an entry that matches nothing fails: the aircraft NPD distances_m (tables printed in feet), the underwater frequencies_hz (formulas printed in kHz), BandAveragedStiffness.center_frequencies.

N13. Name the time signal x, first, and a signal of one physical quantity for it, with its unit #

Why. Thirty functions took the time signal as signal or signal_in while octave_filter(x, fs) took x, and their error messages named a parameter the caller had not written. A signal that is one physical quantity is the other way round: the underwater levels took pressure, the multiple-shock model acceleration and the impact functions force, a word without the unit the formula assumes, while the DIN 4150 functions already took velocity_mm_s.

Do

import numpy as np
from phonometry import filters, underwater

x = np.zeros(48000)
result = filters.octave_filter(x, 48000)
spl = underwater.sound_pressure_level(np.full(1000, 2.0))  # pressure_pa

Don't

def thd(signal, fs): ...
def loudness_ecma(signal_in, fs): ...
def sound_pressure_level(pressure, *, reference=1e-6): ...

Enforced by: tests/test_public_vocabulary.py::test_the_time_signal_is_x, tests/test_public_vocabulary.py::test_a_signal_named_for_its_quantity_carries_its_unit

Exceptions. A record field that holds an output signal keeps signal (EnvelopeResult.signal). Two signals are named by role (x and y; p1 and p2; incident_ir and reflected_ir; clean and degraded), and an impulse response is ir. A record in any unit is x, not record. The quantity signals carry their unit: pressure_pa, acceleration_m_s2, force_n, velocity_mm_s. The tests refuse the names signal and signal_in, and a parameter or field typed as a signal (Signal, SignalInput) named for a quantity without its unit; they do not check the position.

N14. Name a parameter speed_of_sound or density, never by its symbol c or rho #

Why. A bare c or rho at a call site reads as any number, while the API spells the quantity out everywhere else.

Do

def impedance(density: float, speed_of_sound: float) -> float:
    return density * speed_of_sound

Don't

def impedance(rho, c): ...

Enforced by: tests/test_public_vocabulary.py::test_a_symbol_is_not_a_parameter_name_outside_the_solvers

Exceptions. The simulation package is exempt as a whole: its solvers take maps of the symbols their equations are written in (c, rho, c_p, c_s, dx). One parameter elsewhere is kept by location with its reason in _SYMBOL_EXEMPT of the test: the downstream amplitude C of ASTM E2611-19 in four_microphone.face_quantities.

N15. Name an array in the plural; a singular vectorized name says it takes either #

Why. Thirteen functions took a band axis as level= or frequency=, and 34 vectorized parameters did not say whether they take one value or many, so a caller could not tell what to pass.

Do

import numpy as np
from numpy.typing import ArrayLike


def energy_mean(levels: ArrayLike) -> float:
    """Energy mean of ``levels``, in dB."""
    return float(10 * np.log10(np.mean(10 ** (np.asarray(levels) / 10))))

Don't

def energy_mean(level: ArrayLike) -> float: ...

Enforced by: tests/test_public_vocabulary.py::test_an_array_of_a_quantity_is_named_in_the_plural

Exceptions. A vectorized evaluator keeps its singular name when its :param text says it takes one value or many, (scalar or array) (the porous models' frequency). A unit suffix does not change the rule (frequency_hz holding a band axis is a singular array).

N16. Put the unit in the name of a scalar quantity, and leave a band axis bare #

Why. A number the caller types is where a unit is lost, silently: a static pressure of 101325 handed to a function that wants kilopascals is a thousand atmospheres, and every result is still a float. No guard on magnitude can catch it, because both readings are legitimate elsewhere in the library. A band axis is the other way round: frequencies, levels, times and distances are one word each across the library, and a suffix would give the same field a second spelling.

Do

from phonometry import fluids

air = fluids.air(temperature_c=20.0, static_pressure_pa=101325.0, relative_humidity_percent=50.0)

Don't

atmospheric_absorption(100.0, temperature=15.0, humidity=70.0, pressure=101.325)
result.frequencies_hz  # a band axis carries no unit

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py, tests/test_public_vocabulary.py::test_one_concept_is_spelled_one_way

Exceptions. The guard demands the unit on the quantities where two customary units compete, the ones scripts/check_parameter_units.py lists (pressure, temperature, humidity, diameter, angle, period, gradient, molar mass, thickness, spacing, height, phase, speed, attenuation rates; distance inside aircraft); any other scalar keeps a unit it carries, so a single frequency is frequency_hz and a time signal of one quantity is pressure_pa (N13). A name built on a listed quantity may instead end in a suffix that says it has no unit of its own (pressure_ratio, temperature_correction: _level, _index, _ratio, _coefficient, _correction, _uncertainty); a quantity in decibels follows N23 and N24. A bool parameter is outside the rule. Anything else goes in EXEMPT of the guard, keyed by (module, qualified name, parameter) with its reason (acoustic waveforms, ratios of two figures in any unit); a stale entry fails. A band axis carries no unit (N12), except two second units: distances_m in aircraft (NPD tables in feet) and frequencies_hz in underwater (formulas in kHz).

N17. Spell each unit suffix one way: _deg, _s, _minutes, _hours, _kmh, _kt #

Why. phase_tolerance_degrees sat beside _deg, a trailing _h meant hours on one name and henries on inductance_h, _min read as a minimum in assessment_period_min, and subject_m read as meters. One spelling per unit: _deg, _rad, _s, _minutes, _hours, _kmh, _kt, _db_per_s.

Do

def exposure(duration_s: float, angle_deg: float, period_hours: float) -> float:
    return duration_s * angle_deg * period_hours

Don't

def exposure(duration_seconds, angle_degrees, period_h): ...

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_the_tree_spells_every_unit_one_way, review

Exceptions. The retired spellings the guard refuses are _degrees, _seconds, _km_h, _db_s, _knots and an _h that means hours. An _min that means minutes is retired too (_min is a minimum): the guard reports it on a period or another quantity it lists (assessment_period_min names no unit), and on any other duration it is review. A name that means something else by the suffix goes in SPELLING_EXEMPT of the guard with its reason (inductance_h is the henry). An hour or a minute that ends a compound rate is a denominator and stays (_mm_h, _ft_per_min).

N18. Name an absolute temperature in degrees Celsius, _c, and a temperature interval in kelvin, _k #

Why. GasStream(inlet_temperature_k=450.0) renamed to _c with the number kept made the gas 273.15 K hotter without an error. With 29 of 31 public temperatures already in degrees Celsius, the other two moved to Celsius rather than keeping a kelvin name: one scale for a temperature, without exceptions. An interval is the other case: a difference, a tolerance, an uncertainty of a temperature and a coefficient per degree are the same number in kelvin and in degrees Celsius, and the SI writes an interval in kelvin whichever of the two a standard prints (Directive (EU) 2015/996 prints the CNOSSOS-EU coefficient in dB/°C, ISO 10847 its tolerance in °C), so temperature_coefficient_db_per_c read as a temperature where _per_k reads as a rate.

Do

from phonometry import environment

attenuation = environment.air_attenuation([1000.0], temperature_c=10.0, relative_humidity_percent=70.0)
coefficient = environment.ROAD_COEFFICIENTS.temperature_coefficient_db_per_k

Don't

fluids.air(temperature_k=293.15)
temperature_coefficient_db_per_c

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_the_tree_writes_every_temperature_on_its_scale, tests/test_check_parameter_units.py::test_the_temperature_scale_rule_reads_a_name

Exceptions. A coefficient per degree ends in _per_k. An interval of temperature ends in _k and is listed in TEMPERATURE_INTERVALS of the guard, keyed by (module, qualified name, parameter) with its reason (u_temperature_k of the reciprocity uncertainty budgets, TEMPERATURE_TOLERANCE_K of ISO 10847), so a new one is read before it is admitted; a stale entry fails.

N19. Name the pressure of the medium static_pressure_pa or static_pressure_kpa #

Why. The absolute pressure of the medium had five names: static_pressure_kpa, atmospheric_pressure_kpa, atmospheric_pressure_pa, barometric_pressure_pa and ambient_pressure_pa.

Do

from phonometry import materials

density = materials.air_density_iso10534(temperature_c=23.0, static_pressure_kpa=101.325)

Don't

def air_density(temperature_c, ambient_pressure): ...
def speed_of_sound(temperature_c, barometric_pressure_hpa): ...

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_the_pressure_of_the_medium_has_one_stem

Exceptions. Each function keeps the pascal or kilopascal its clause prints. atmospheric_pressure_pa names only the outside atmosphere, where the same signature also takes a stream pressure (ATMOSPHERIC_ADMITTED of the guard: pipe_transmission_loss, normal_air_density and others).

N20. End a rate per distance in _db_per_m, _db_per_km or _per_m #

Why. An attenuation in dB/m, dB/km or Np/m differs by orders of magnitude for one number, and an absorption_coefficient in dB/km beside the dimensionless absorption coefficient of a wall reads as the wall's.

Do

def air_loss(distance_m: float, air_absorption_db_per_m: float) -> float:
    return distance_m * air_absorption_db_per_m

Don't

def air_loss(distance_m, absorption_coefficient): ...  # documented in dB/km

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_the_tree_holds_every_closing_rule

Exceptions. The guard holds a name that says absorption, attenuation or coefficient and whose docstring gives a unit per distance. A name that is not a rate goes in RATE_EXEMPT of the guard with its reason.

N21. Never publish one name both bare and with its unit in one subpackage #

Why. A subpackage where thickness and thickness_m are both public makes the caller guess whether the bare one is in meters. Keep the unit where a second unit competes for the word (N16), and otherwise pick one spelling for the subpackage.

Do

def layer(thickness_m: float, spacing_m: float) -> float:
    return thickness_m + spacing_m

Don't

def layer(thickness_m): ...
def plate(thickness): ...  # same subpackage, same quantity

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_the_tree_holds_every_closing_rule

Exceptions. Two different quantities under one word (a subscript such as r_w beside a watt, l_n beside newtons, an A-weighted figure beside the band one) go in PAIR_EXEMPT of the guard with their reason. A frequency is the one quantity kept both ways on purpose: the bare word is a result's stated frequency or a vectorized argument, frequency_hz the scalar argument (N16), and the pair is listed there for each subpackage that has both.

N22. Make every defaulted unit-named parameter and every medium condition keyword-only #

Why. A unit in the name helps only if the name appears at the call: with a default and a positional slot the number is written bare, and ground_attenuation(200, 2, 2, bands, 1, 1, 1), sound_exposure(x, fs, 8.0, cal) or noise_signal(fs, 2.0) reads as a row of numbers in an order nobody remembers. A frequency axis and a record a caller builds are taken by keyword too (A17, A18).

Do

from phonometry import environment, signals

attenuations = environment.atmospheric_absorption(100.0, temperature_c=15.0, relative_humidity_percent=70.0)
noise = signals.noise_signal(48000, duration_s=0.5, seed=1)

Don't

def absorption(distance, temperature_c=20.0, speed_of_sound=343.0): ...

absorption(100.0, 15.0, 340.0)
noise_signal(48000, 0.5)

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_every_condition_on_the_tree_is_written_by_name, tests/test_check_parameter_units.py::test_a_unit_named_default_is_passed_by_name

Exceptions. The conditions of the medium and of the measuring chain are held to it whatever their suffix (speed_of_sound, air_density, air_sound_speed, water_density, calibration_factor, the ground factors; CONDITIONS of the guard), and every defaulted parameter whose name ends in a unit of the guard's UNITS whatever quantity it names (duration_s, length_m, high_hz, wind_directions_deg). The first parameter is not held to it, nor an option (mode, method, fraction, n, seed), nor a condition the call cannot do without (tube_wavenumber(frequency, speed_of_sound)). A record's fields are held by A18. A signature that must stay positional goes in POSITIONAL of the guard with its reason (metrology.sensitivity(reference_pressure_pa), part of the Signal overload contract).

N23. Leave _db off a level or a level difference; keep it on other decibel quantities #

Why. About 400 names ended in _db beside as many that did not, often the same concept in two modules (background_levels_db and background_levels, insertion_loss_db and insertion_loss). The head noun decides: a level, loss, insulation, reduction, difference, improvement, correction, adjustment, index or emergence carries no _db; a tolerance, margin, limit, uncertainty, deviation, step, slope, rate or ratio keeps it.

Do

def correct(levels: list[float], background_levels: list[float], fixture_uncertainty_db: float) -> list[float]:
    return [a - b + fixture_uncertainty_db for a, b in zip(levels, background_levels, strict=True)]

Don't

def correct(levels_db, background_levels_db, fixture_uncertainty): ...

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_no_level_carries_a_unit_suffix

Exceptions. The head noun is the last noun once trailing qualifiers are set aside (_1000, _a, _before, _with, _max). Level nouns: level, loss, insulation, isolation, reduction, rejection, difference, improvement, single-value attenuation, correction, adjustment, index, emergence, the ISO 717 adaptation term, and a shift, increase, decrease or excess of a named level; also a printed symbol of one (l_n, delta_lw; kij in building, max_k3 in emission). A drop, rise, change or increment of a named level is one too (level_drop); a bare shift or drop_db names no level and keeps its unit, and in materials an l1 is the length of ASTM E2611, not a level. A tolerance, margin, uncertainty, deviation, step, slope (_db_per_decade), rate (_db_per_m) or ratio keeps _db, and so does a statistic of a level (sigma_level_db: a leading sigma_ or u_ says it). A difference or a loss of another quantity keeps that quantity's unit (phase_difference_deg; a pressure loss is in pascals). LEVEL_SUFFIX_EXEMPT of the guard lists, with its reason, a name that holds something else under the word.

N24. Give a name in decibels the noun of its quantity, never qualifiers plus _db #

Why. corrected_db, floor_db, threshold_db and mean_db said the unit and not the number: a caller could not tell a level from an uncertainty or a margin.

Do

def hearing_threshold(threshold_level: float, *, expanded_uncertainty_db: float) -> float:
    """The threshold level, in dB, with its expanded uncertainty."""
    return threshold_level

Don't

def hearing_threshold(threshold_db, floor_db): ...

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_every_name_in_decibels_says_its_quantity

Exceptions. A level takes the noun that says so and then loses its _db (corrected_levels, threshold_level), a level difference takes its own (floor_level_difference), and any other quantity keeps _db after its noun (fixture_uncertainty_db, lower_tolerance_db). The nouns read as a quantity are DECIBEL_QUANTITY_NOUNS of the guard; QUALIFIER_ONLY_EXEMPT lists, with its reason, a name whose _db is not the unit of a number it holds (a flag, a printed symbol, the DB HR of the Spanish building code).

N25. End a published constant's name in its unit unless it is a pure number #

Why. A constant is a number nobody types, so the unit lost is the one a reader assumes: a reference speed of 70 is km/h in CNOSSOS-EU while other speeds are in m/s or kt, and a reference velocity of 5e-8 is m/s only to a reader with the docstring open.

Do

from phonometry import fluids

static_pressure = fluids.DEFAULT_STATIC_PRESSURE_PA

Don't

ROAD_REFERENCE_SPEED = 70.0
UNIVERSAL_GAS_CONSTANT = 8314.0

Enforced by: scripts/check_parameter_units.py, make parameter-units, CI: Every public quantity names its unit, tests/test_check_parameter_units.py::test_every_published_constant_says_its_unit

Exceptions. A single number ends in its unit, in the one spelling each unit has (_HZ, _M_S, _KMH, _KT, _DEG, _S, _HOURS), or in _DB when it is in decibels and its head noun does not say so (a tolerance, a margin); a constant named for a level carries none (EARPHONE_ATTENUATION). A factor, a fraction or a ratio carries none. A table ends in its unit when its name names a quantity (NOY_BANDS_HZ). A count, a label or a pure number goes in CONSTANT_EXEMPT of the guard, keyed by (module, name) with its reason.

N26. Name a private constant _UPPER_SNAKE, and a transcribed table after its printed table #

Why. A private table named for where it is printed can be checked against the page, and the leading underscore keeps it out of the public API.

Do

_TABLE1   Table 1 of ISO 12999-1, in building/measurement/uncertainty.py
_UVL0     the columns u, v and L0 of Table 1 of ISO 1999, in hearing/noise_induced_hearing_loss.py

Don't

table1, _table_1, TABLE1 (public by accident)

Enforced by: review

Exceptions. A private constant that is not a transcription is named for its content (_OCTAVE_BANDS).

N27. Delete a private constant nothing reads #

Why. A private constant nobody reads is a leftover, or the trace of a check its docstring still promises: the sweep that created this guard found a recommended specimen velocity the code carried and never checked, and a docstring promising a default the code did not take.

Do

_MAX_SPECIMEN_VELOCITY_M_S = 0.5


def specimen_velocity_margin(velocity_m_s: float) -> float:
    return _MAX_SPECIMEN_VELOCITY_M_S - velocity_m_s

Don't

_MAX_SPECIMEN_VELOCITY_M_S = 0.5  # defined, cited in a docstring, never compared

Enforced by: scripts/check_dead_constants.py, make dead-constants, CI: No private constant goes unread

Exceptions. A name counts as read when it is loaded, used as an attribute, imported or named in a string anywhere in src, tests or scripts. KEPT in the script takes a constant, keyed (module, name), with its reason, and nothing belongs there that could be used instead. A constant kept only for documentation belongs in a docstring.

N28. Spell words out: microphone, laboratory, reference, standard_deviation, frequency, confidence #

Why. mic_calibration_factor, lab_airborne_insulation, levels_ref, delay_std, bank.freq and ci_lower each had a spelled-out twin elsewhere in the API.

Do

from phonometry import emission, materials

materials.microphone_calibration_factor
emission.sound_power_comparison  # takes reference_levels=

Don't

mic_calibration_factor(...)
sound_power_comparison(levels, levels_ref, lw_ref)
result.delay_std
result.ci_lower

Enforced by: tests/test_public_vocabulary.py::test_words_are_spelled_out, tests/test_public_vocabulary.py::test_the_row_keys_of_a_verdict_are_spelled_out, tests/test_public_vocabulary.py::test_every_kept_spelling_still_exists

Exceptions. A confidence bound is confidence_lower or confidence_upper; ci is a word of no public name except the impact sound adaptation term of ISO 717-2 (ci, ci_delta, ci_r). fs, min, max and n_ are established terms, not abbreviations, and so are the acronyms SPL, SEL, SNR and RMS, terms of art like L_max. The public attributes a plain class sets on self and the row keys of verdict dictionaries are held too. A spelling kept on purpose goes in _SPELLING_EXEMPT of the test, keyed by location with its reason.

N29. Write min and max in every public name, MIN and MAX in a constant #

Why. Scientific Python writes min and max (numpy min and max, SciPy maxiter, scikit-learn max_iter, Matplotlib vmin), the standards print Lmax and Lmin, and the library already wrote min_ and max_ about three times as often as minimum_ and maximum_. A maximum in decibels is the maximum level, max_level.

Do

from phonometry import environment

environment.RAILWAY_MIN_SPEED_KMH

Don't

railway_source_power(minimum_speed_kmh=...)
plant_steady_reading(maximum_level=..., max_db=...)

Enforced by: tests/test_public_vocabulary.py::test_words_are_spelled_out

Exceptions. A class writes Min and Max (MaxUncertaintyRow). Terms of art are included: Lmax and Lmin are max_level and min_level, never a bare max_db, and the minimum-phase reconstruction is min_phase.

N30. Name a count n_<plural>, and a limit on one min_n_ or max_n_ #

Why. events=3 could be read as the events themselves, and num_points, blade_count and harmonics each spelled a count differently from n_samples.

Do

from phonometry import vibration

vibration.story_fundamental_frequency(n_stories=8)

Don't

story_fundamental_frequency(stories=8)
verify_filter_class(..., num_points=16)

Enforced by: tests/test_public_vocabulary.py::test_a_count_is_n_plural, tests/test_public_vocabulary.py::test_every_kept_count_spelling_still_exists

Exceptions. Not counts: a class or grade number (filter_class), an axis, the decimals a value is rounded to, degrees of freedom, a length counted in samples or grid cells (delay_samples). A vectorized argument that takes one count or many keeps its plural, and an array of tallies is not one count (counts). Kept spellings go in _COUNT_EXEMPT of the test, keyed by location with their reason. num_ is refused by N28.

N31. Name a duration by its quantity, then its unit #

Why. The sweep generators took seconds=, lden took hours= and the ISO 1999 functions took years=: names that say a unit and not what lasts. The rule holds whatever the name holds: one number, the durations of several periods, or an array.

Do

from phonometry import signals

noise = signals.noise_signal(48000, duration_s=1.0)

Don't

sweep_signal(fs, seconds=2.0)
htlan(..., years=10)

Enforced by: tests/test_public_vocabulary.py::test_a_count_is_n_plural, tests/test_public_vocabulary.py::test_a_duration_ends_in_its_unit, tests/test_public_vocabulary.py::test_every_kept_duration_spelling_is_still_one

Exceptions. A rate is not a duration (seconds_per_decade). The first test refuses a name that is a unit alone; the second refuses a public parameter, field, property, function, method, constant (TAKT_DURATION_S is read as takt_duration_s) or attribute a plain class sets on self, a property or a method a public class inherits from a private base included, with the word duration or durations that does not end in _s, _ms, _minutes, _hours, _days or _years. A choice or a switch holds no length of time (duration: Literal["short_term", "long_term"], include_duration_uncertainty: bool, a function that returns a bool), and a suffix that says the value holds no length of time ends the name instead (duration_correction, in decibels). The uncertainty of a duration is a length of time and ends in its unit (sweep_duration_uncertainty_s). A name that keeps the word without a unit goes in _DURATION_EXEMPT of the test, keyed by location with its reason: the sub-interval durations of environment.rating_level, in the unit of its reference_time, and the verb building.check_background_duration. How the unit is spelled, a minute included, is N17.

N32. Spell every identifier and every value a caller types in American English #

Why. acoustic_centre sat beside center_frequencies and programme beside program_loudness, so a caller who wrote one spelling met a TypeError on the next function. Values count too: a Literal choice, a default, an enum value, a table key, a string of a published tuple.

Do

from phonometry import materials, vibration

vibration.centered_interval, materials.in_situ_absorption_coefficient

Don't

centred_interval(...)
insitu_absorption_coefficient(...)
location="centre"

Enforced by: scripts/check_identifier_spelling.py, make identifier-spelling, CI: Every public quantity names its unit

Exceptions. In situ is in_situ (InSitu in a class). catalogue is the one sanctioned British form: it is an American variant too, used uniformly, and part of the file format users write (the catalogue key, phonometry-catalogue, the schema URN). A string a published source prints keeps its print, in EXEMPT of the script, keyed by location with its reason ('optimised brushed down concrete', 'aluminium', the surname Doutres). The check reads -ise, -yse, -our, -tre and -bre as whole families. Prose in docstrings, guides and comments is not held to it.

N33. Write a printed symbol in a public name in lower snake case #

Why. The standards print Rw, LAeq and R'; a public name writes them r_w, l_aeq and r_prime, so the API reads in one case and a symbol's prime is a word, not a quote.

Do

def sound_reduction(r_w: float, l_aeq: float) -> float:
    return l_aeq - r_w

Don't

def sound_reduction(Rw: float, LAeq: float) -> float: ...

Enforced by: review

Exceptions. A local variable may keep the printed case (Rw = ...); that is why ruff's N naming rules are not selected (only N812, on import aliases, is).

N34. Name a type alias in PascalCase #

Why. An alias reads as a type at the call site and in the API reference, which prints it as its definition. It stays private to its module (A5).

Do

from typing import Literal

Language = Literal["en", "es"]

Don't

language_t = Literal["en", "es"]

Enforced by: review

N35. Put a standard's designation in a name only where it tells two things apart, and write it one way #

Why. About 56 public names carried a designation in mixed forms: EN_12354_AIR beside ISO7235_AIR_GAS_CONSTANT_J_KG_K, sae_band_attenuation beside air_density_iso10534, and ISO1683_REFERENCE_VALUES in the module that implements nothing but ISO 1683. A designation the module already states is noise in the name, and two forms of one designation are two names to remember.

Do

from phonometry import building, materials, metrology

air = building.EN12354_AIR
density = materials.air_density_iso10534(temperature_c=23.0, static_pressure_kpa=101.325)
p0 = metrology.REFERENCE_VALUES["gas"]["sound_pressure"].value

Don't

building.EN_12354_AIR
metrology.ISO1683_REFERENCE_VALUES
iso_9613_ground_factor

Enforced by: tests/test_public_vocabulary.py::test_a_standard_designation_is_written_one_way_and_only_where_it_distinguishes, tests/test_public_vocabulary.py::test_the_designation_rule_reads_a_name

Exceptions. A designation stays where it separates two things the module does not (air_density_iso10534 and air_density_astm_e2611, the IEC 61094 tables of metrology). It joins the body to the number, takes a part after an underscore (IEC61094_2_), and comes first in a constant, a class or a field and last in a function (band_attenuation_arp5534). Every designation that stays is listed in _DESIGNATION_KEPT of the test with its reason; a module is named for its subject, never for a designation (N1).