[READ-ONLY] Mirror of https://github.com/jmrplens/phonometry. Standards-conformant acoustics library for Python: measurement and metrology, docs.jmrp.io/phonometry
phonometry docs CONFORMANCE.md

Auto-generated conformance report - do not hand-edit. Produced by make conformance from the library's own computations checked against the referenced standards. CI regenerates it on every pull request and fails if it is out of date, so edit the checks in scripts/conformance_report.py, not this file. Each row pins a standard and clause to its expected normative value and the value the library computes. Full standards list and methodology: Theory - Why phonometry.

Numerical conformance report #

✅ 60/60 conformance checks pass across 12 domains and 37 standards - filters class 1 - weightings within IEC 61672-1 class 1.

Numerical validation - filters & weightings #

IEC 61260-1:2014 class per filter architecture (order 6, one-third-octave, 100 Hz-10 kHz, fs = 48 kHz). For each architecture the table shows, at its binding band, the measured relative attenuation and the class-1 limit it must clear, so the number and the range it must sit in are both visible. A positive margin means the acceptance limits are met with that much room.

Architecture Class verdict Binding band Measured rel. atten. Class-1 limit Margin cl.1 Margin cl.2
butter Class 1 (default) 100 Hz +0.00 dB ≥ -0.40 dB +0.400 dB +0.600 dB
cheby1 By design (passband ripple) 6310 Hz +0.19 dB ≥ +1.44 dB -1.246 dB -0.837 dB
cheby2 Class 1 100 Hz +0.00 dB ≥ -0.40 dB +0.400 dB +0.600 dB
ellip By design (passband ripple) 10000 Hz +0.10 dB ≥ +1.32 dB -1.218 dB -0.813 dB
bessel By design (soft rolloff) 100 Hz +12.46 dB ≥ +16.60 dB -4.133 dB -3.133 dB

Only Butterworth (the library default) and Chebyshev-II are class-compliant architectures. Chebyshev-I and elliptic trade the mask for passband ripple, and Bessel for a maximally-flat group delay (soft rolloff); they cannot satisfy the IEC 61260-1 Class 1/2 attenuation mask by construction, so they are labelled By design - this is expected, not a failure or regression.

Frequency-weighting conformance (A/C: IEC 61672-1 Table 3; G: ISO 7196 A.3). The max deviation from nominal is informational (it falls at a frequency extreme where the tolerance is widest and asymmetric); compliance is judged at the binding frequency - the one with the least headroom - where the deviation, the applicable tolerance band and the headroom are shown together.

Curve fs Max dev. from nominal (info) Binding freq Deviation there Tolerance band Headroom
A 48 kHz -0.902 dB @ 20000 Hz 1000 Hz +0.000 dB [-0.70, +0.70] dB +0.700 dB
A 96 kHz -0.515 dB @ 20000 Hz 1000 Hz +0.000 dB [-0.70, +0.70] dB +0.700 dB
C 48 kHz -0.935 dB @ 20000 Hz 1000 Hz +0.000 dB [-0.70, +0.70] dB +0.700 dB
G 48 kHz +0.047 dB @ 1 Hz 1 Hz +0.047 dB [-1.00, +1.00] dB +0.953 dB
✅ Filters & weightings — 100% (5/5)
Standard Quantity Expected (norm) Computed Δ Status
IEC 61260-1:2014 Table 1 Octave-band filter class (butterworth, fs=48 kHz) class 1 class 1 (margin +0.400 dB) +0.400 dB ✅
IEC 61260-1:2014 Table 1 One-third-octave filter class (butterworth, fs=48 kHz) class 1 class 1 (margin +0.400 dB) +0.400 dB ✅
IEC 61672-1:2013 Table 3 A-weighting deviation vs class-1 limits (fs=48 kHz) deviation within limits @ 1000 Hz +0.000 dB in [-0.70, +0.70] dB headroom +0.700 dB ✅
IEC 61672-1:2013 Table 3 C-weighting deviation vs class-1 limits (fs=48 kHz) deviation within limits @ 1000 Hz +0.000 dB in [-0.70, +0.70] dB headroom +0.700 dB ✅
ISO 7196:1995 Table 2 / A.3 G-weighting deviation vs +/-1 dB tolerance (fs=48 kHz) deviation within limits @ 1 Hz +0.047 dB in [-1.00, +1.00] dB headroom +0.953 dB ✅
✅ Levels & dosimetry — 100% (3/3)
Standard Quantity Expected (norm) Computed Δ Status
IEC 61672-1:2013 (Leq) Leq of a 1 Pa 1 kHz sine 90.97 dB (+/-0.05 dB) 90.969 dB -0.001 dB ✅
IEC 61252:1995 (LEX,8h) 8 h exposure to 90 dB(A) noise 90 dB (+/-0.05 dB) 90.008 dB 0.008 dB ✅
ISO 1996-1:2016 3.6.4 Lden, constant 60 dB in day/evening/night 66.3952 dB (+/-0 dB) 66.3952 dB 0 dB ✅
✅ Psychoacoustics — 100% (10/10)
Standard Quantity Expected (norm) Computed Δ Status
ISO 532-1:2017 Annex B.2 Zwicker loudness N, stationary test signal 1 83.2957 sone (+/-0.1%) 83.2957 sone 0 sone ✅
ISO 532-1:2017 Annex B.5 Time-varying loudness Nmax, technical signal 14 (aircraft, free field) 22.6399 sone (+/-0.1%) 22.6399 sone 0 sone ✅
ISO 532-1:2017 Annex B.5 Time-varying loudness Nmax, technical signal 15 (vehicle interior, diffuse field) 9.6059 sone (+/-0.1%) 9.6059 sone 0 sone ✅
DIN 45692:2009 Clause 6 Sharpness of the standard 1 kHz reference signal 1 acum (+/-0 acum) 1 acum 0 acum ✅
ISO 226:2023 Table B.1 Equal-loudness contour, 60 phon @ 100 Hz 78.5 dB SPL (+/-0.05 dB SPL) 78.504 dB SPL 0.004 dB SPL ✅
ECMA-418-2:2025 Clause 5.1.8 HMS loudness of a 1 kHz / 40 dB tone (c_N=0.0211964) 1 sone_HMS (+/-0.03 sone_HMS) 0.9958 sone_HMS -0.004 sone_HMS ✅
ECMA-418-2:2025 Clause 6.2.8 HMS tonality of a 1 kHz / 40 dB tone (c_T=2.8758615) 1 tu_HMS (+/-0.03 tu_HMS) 0.9998 tu_HMS 0 tu_HMS ✅
ECMA-418-2:2025 Clause 7 HMS roughness of a 1 kHz / 70 Hz / m=1 / 60 dB tone (c_R=0.0180685) 1.0735 asper (+/-0.01 asper) [clean-room; standard target 1] 1.0735 asper 0 asper ✅
ISO 532-2:2017 Clause 3.17 / Annex B.1 Moore-Glasberg loudness of a 1 kHz / 40 dB tone (C=0.0617) 1 sone (+/-0.01 sone) 1.0001 sone 0 sone ✅
ISO 532-3:2023 Annex C.1 Moore-Glasberg-Schlittenlacher peak LTL, steady 1 kHz / 40 dB 1 sone (+/-0.02 sone) 0.9996 sone 0 sone ✅
✅ Speech intelligibility — 100% (2/2)
Standard Quantity Expected (norm) Computed Δ Status
IEC 60268-16:2020 A.2.2 STI weighting-factor pair (500 Hz + 1 kHz bands) 0.398 (+/-0.001) 0.398 0 ✅
IEC 60268-16:2020 A.3.1.2 Uniform MTF m=0.5 maps to STI=0.5 0.5 (+/-0.01) 0.5 0 ✅
✅ Intensity & sound power — 100% (4/4)
Standard Quantity Expected (norm) Computed Δ Status
IEC 61043:1994 Clause 5 Plane-wave intensity I = p^2 / (rho c) 0.00238 W/m^2 (+/-1.5%) 0.00239 W/m^2 0 W/m^2 ✅
ISO 3744:2010 Eq. 18 Monopole hemisphere recovers LW (r=4 m) 95 dB (+/-0 dB) 95 dB 0 dB ✅
ISO 9614-2:1996 Eq. 12 Intensity scan recovers LW of an enclosed source 90 dB (+/-0.000001 dB) 90 dB 0 dB ✅
ISO 3741:2010 Eq. 20 Reverberation-room method inverts to a known LW 0 dB error 0 dB 0 dB ✅
✅ Room & building acoustics — 100% (8/8)
Standard Quantity Expected (norm) Computed Δ Status
ISO 3382-2:2008 5.3.3 T30 from a synthetic exponential decay (T=1.0 s) 1 s (+/-1%) 1 s 0 s ✅
ISO 717-1 Annex C, Table C.1 Weighted sound reduction index Rw (C;Ctr) Rw 30 (C -2; Ctr -3) Rw 30 (C -2; Ctr -3) sum 31.8 dB ✅
ISO 354:2003 Eq. 5/8 Sabine inversion recovers absorption area 9.212828 m^2 (+/-0 m^2) 9.212828 m^2 0 m^2 ✅
ISO 3382-3:2012 Clause 6.2 Open-plan spatial decay rate D2,S (-6 dB/doubling) 6 dB (+/-0 dB) 6 dB 0 dB ✅
ISO 16283-3:2016 Clause 3.12 Facade R'45 isolates the -1.5 dB incidence correction (S=A) 38.5 dB (+/-0 dB) 38.5 dB 0 dB ✅
ISO 10140-2:2010 Formula (2) Lab airborne R on the ISO 717-1 reference shape -> Rw = 54 Rw 54 dB Rw 54 dB +0 dB ✅
ISO 9613-1:1993 Table 1 Air attenuation @ 10 degC, 70 %, 1 kHz 3.66 dB/km (+/-0.01 dB/km) 3.658 dB/km -0.002 dB/km ✅
ISO 9613-1:1993 Table 1 Air attenuation @ 0 degC, 20 %, 2 kHz 34.6 dB/km (+/-0.1 dB/km) 34.64 dB/km 0.04 dB/km ✅
✅ Building prediction & uncertainty — 100% (4/4)
Standard Quantity Expected (norm) Computed Δ Status
EN 12354-1:2000 Annex H.3 Airborne prediction R'w (direct + 12 flanking paths) R'w 52 dB (13 paths) R'w 52 dB (13 paths, 52.17) +0.17 dB ✅
EN 12354-2:2000 Annex E.3 Impact prediction L'n,w = Ln,w,eq - dLw + K 45 dB (+/-0 dB) 45 dB 0 dB ✅
ISO 12999-1:2020 Table 2 Airborne band uncertainty, situation A @ 1 kHz 1.8 dB (+/-0 dB) 1.8 dB 0 dB ✅
ISO 12999-1:2020 Clause 8 / Table 8 Expanded uncertainty U = 1.96 u (95 % two-sided, Rw sit. A) 2.352 dB (+/-0 dB) 2.352 dB 0 dB ✅
✅ Outdoor propagation & occupational exposure — 100% (7/7)
Standard Quantity Expected (norm) Computed Δ Status
ISO 9613-2:1996 Eq. (7) Geometrical divergence Adiv = 20 lg(d/d0) + 11 at 100 m 51 dB (+/-0 dB) 51 dB 0 dB ✅
ISO 9613-2:1996 Table 3 Ground b'(0) porous limit -> Agr(250 Hz) = 2(-1.5 + 10.1) 17.2 dB (+/-0 dB) 17.2 dB 0 dB ✅
ISO 9613-2:1996 clause 7.4 Single-edge diffraction saturates at the 20 dB cap 20 dB (+/-0 dB) 20 dB 0 dB ✅
ISO 9613-2:1996 clause 7.4 Double-edge diffraction saturates at the 25 dB cap 25 dB (+/-0 dB) 25 dB 0 dB ✅
ISO 9612:2009 Annex D Task-based LEX,8h + U (welder day, case a) LEX,8h 84.3; U 2.7 dB LEX,8h 84.3; U 2.7 dB -0.01; +0.02 dB ✅
ISO 9612:2009 Annex E Job-based LEX,8h + U (production line, 18 workers) LEX,8h 88.1; U 3.8 dB LEX,8h 88.2; U 3.8 dB +0.06; -0.03 dB ✅
ISO 9612:2009 Annex F Full-day LEX,8h + U (forklift drivers) LEX,8h 90.1; U 3.4 dB LEX,8h 90.1; U 3.4 dB +0.02; +0.03 dB ✅
✅ Materials: absorption, airflow & impedance — 100% (5/5)
Standard Quantity Expected (norm) Computed Δ Status
ISO 11654:1997 Annex A.1 Weighted absorption alpha_w (no indicator) 0.60 (class C, no indic.) 0.60 (class C, '') 0 ✅
ISO 11654:1997 Annex A.2 Weighted absorption alpha_w with M indicator 0.60(M) 0.60(M) 0 ✅
ISO 9053-2:2020 Annex A.3 Thermal boundary-layer thickness b 0.00183 m (+/-0.00001 m) 0.00183 m 0 m ✅
ISO 9053-2:2020 Annex A.3 Effective ratio of specific heats kappa' 1.37 (+/-0.001) 1.37 0 ✅
ISO 10534-1:1996 Eqs (9)/(13)/(14) Absorption from standing-wave ratio s=3 0.75 (+/-0) 0.75 0 ✅
✅ Scattering & diffusion (ISO 17497) — 100% (5/5)
Standard Quantity Expected (norm) Computed Δ Status
ISO 17497-1:2004 Eq (2) Reference speed of sound at 20 C 343.2 m/s (+/-0 m/s) 343.2 m/s 0 m/s ✅
ISO 17497-1:2004 Eqs (1)/(4)/(5) Scattering coefficient (synthetic chain) 0.0931 (+/-0) 0.0931 0 ✅
ISO 17497-1:2004 Annex A.5 Expanded uncertainty of scattering coefficient 0.02971 (+/-0) 0.02971 0 ✅
ISO 17497-2:2012 Formula (5) Diffusion coefficient (autocorrelation) 0.7367 (+/-0) 0.7367 0 ✅
ISO 17497-2:2012 Formula (8) Zenith area factor (radians convention) 1.57105 (+/-0) 1.57105 0 ✅
✅ In-situ road absorption (ISO 13472) — 100% (3/3)
Standard Quantity Expected (norm) Computed Δ Status
ISO 13472-1:2002 Clause 4.2 Geometrical-spreading factor Kr 0.6667 (+/-0) 0.6667 0 ✅
ISO 13472-1:2002 Annex A Maximum-sampled-area radius 1.3425 m (+/-0 m) 1.3425 m 0 m ✅
ISO 13472-2:2010 Clause 5.4.1 Spot-tube upper usable frequency f_u 1989.4 Hz (+/-0.1 Hz) 1989.4 Hz 0 Hz ✅
✅ Precision sound power (ISO 3745 / 9614-3) — 100% (4/4)
Standard Quantity Expected (norm) Computed Δ Status
ISO 3745:2012 Clause 10.5 EXAMPLE Expanded uncertainty U (k=2) 4.123 dB (+/-0.001 dB) 4.123 dB 0 dB ✅
ISO 3745:2012 Eq (11) K1 background floor (6 dB edge band) 1.2563 dB (+/-0.0001 dB) 1.2563 dB 0 dB ✅
ISO 3745:2012 Eq (16) Meteorological C1 at 23 C reference -0.1282 dB (+/-0.0001 dB) -0.1282 dB 0 dB ✅
ISO 9614-3:2002 Eqs (5)/(8)/(9) Uniform-intensity LW recovery 80 dB (+/-0 dB) 80 dB 0 dB ✅