[READ-ONLY] Mirror of https://github.com/jmrplens/phonometry. Standards-conformant acoustics library for Python: measurement and metrology, docs.jmrp.io/phonometry
phonometry docs levels.md

← Documentation index

Integrated and Statistical Levels #

Environmental noise metrics computed directly from the raw (calibrated) signal.

Leq and LAeq #

The equivalent continuous level integrates the squared pressure over the measurement time:

$$ L_{eq} = 10\log_{10}\left(\frac{1}{T}\int_0^T \frac{p^2(t)}{p_0^2}\ dt\right) \text{ dB}, \qquad p_0 = 20\ \mu\text{Pa} $$

and $L_{Aeq}$ is the same integral after A-weighting the signal. $L_N$ is the level exceeded $N\ %$ of the time — the $(100-N)$-th percentile of the time-weighted level distribution.

import numpy as np
from phonometry import leq, laeq

# recording: a calibrated microphone capture (Pa) — recorded through your measurement chain. Synthesized here so the guide runs standalone.
fs = 48000
recording = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)
sensitivity = 1.0                                    # calibration_factor (see Calibration)

# Equivalent continuous level of the whole recording
level = leq(recording, calibration_factor=sensitivity)

# A-weighted Leq (the standard environmental noise metric)
la = laeq(recording, fs, calibration_factor=sensitivity)

Both accept 1D signals (returning a scalar) or 2D [channels, samples] arrays (returning one level per channel), and support dbfs=True for digital full-scale analysis (calibration does not apply in dBFS mode).

Why the energy mean and not the arithmetic mean of dB values? Because sound doses add as energy: two periods at 60 dB and 80 dB do not average to 70 dB — the 80 dB half dominates and $L_{eq}$ = 77 dB. Averaging decibels directly underestimates every fluctuating noise. $L_{eq}$ is the level of the steady sound carrying the same energy as the real, fluctuating one, which is why regulations are written in terms of it.

leq() / laeq() parameters #

Parameter Type / shape Units Range / default Notes
x 1D or 2D array digital units (or Pa if calibrated) non-empty 2D is [channels, samples]; returns one level per channel
fs int Hz > 0 (laeq only) leq needs no sample rate (pure RMS integral)
calibration_factor float Pa per digital unit default 1.0 From sensitivity()
dbfs bool — default False True: 0 dBFS = full-scale RMS sine; ignores calibration

Percentile levels (LN) #

ln_levels computes statistical levels from the time-weighted envelope: L10 is the level exceeded 10 % of the time (event peaks), L50 the median, L90 the background level.

from phonometry import ln_levels

# A steady tone gives L10 = L50 = L90; percentiles only tell a story for a
# *fluctuating* level. Synthesize 3 s alternating between a quiet and a
# ~10 dB louder half-second so the statistics separate.
rng = np.random.default_rng(0)
segment = fs // 2                                  # 0.5 s per level
quiet = 0.02 * rng.standard_normal(segment)        # background
loud = 0.06 * rng.standard_normal(segment)         # ~10 dB louder events
varying = np.tile(np.concatenate([quiet, loud]), 3)

stats = ln_levels(varying, fs, n=(10, 50, 90), weighting="A")
print(f"LA10={stats[10]:.1f}  LA50={stats[50]:.1f}  LA90={stats[90]:.1f} dB")
# LA10=66.6  LA50=65.2  LA90=58.5 dB  -> L10 (events) > L50 (median) > L90 (background)

Fast level history of fluctuating noise with the L10, L50 and L90 statistical levels marked

L10 tracks the event peaks, L50 the median level and L90 the background.

Options: mode selects the envelope ballistics ('fast', 'slow', 'impulse'), weighting applies A/C weighting first, and calibration_factor/dbfs behave as in leq. The integrator attack transient (~5τ) is discarded before taking percentiles, so the leading settling ramp is not counted in the low percentiles.

Formally, $L_N$ is the $(100-N)$-th percentile of the distribution of the time-weighted level: the recording is first turned into a level-vs-time envelope (Fast by default), and $L_{10}$ is the envelope value exceeded 10 % of the time. That makes the ballistics choice part of the metric: an $L_{10}$ from a Slow envelope is systematically lower than from a Fast one on impulsive noise, so regulations always name the time weighting.

ln_levels() parameters #

Parameter Type / shape Units Range / default Notes
x 1D or 2D array digital units non-empty 2D returns per-channel dicts
fs int Hz > 0 Needed by the envelope detector
n tuple of ints % default (10, 50, 90) Any exceedance percentages, e.g. (1, 5, 95)
mode str — 'fast' (default), 'slow', 'impulse' IEC 61672-1 ballistics of the envelope
weighting str or None — 'A', 'C', 'G', 'Z', None (default) Frequency weighting before the envelope
calibration_factor / dbfs float / bool — as leq Same semantics as in leq()

Peak, event and occupational metrics #

from phonometry import lc_peak, sel, sound_exposure, lex_8h

# C-weighted peak (IEC 61672-1 §5.13) - occupational action limits use this
peak = lc_peak(recording, fs, calibration_factor=sensitivity)

# A single noise event and a work-shift sample (slices of a real recording)
event = recording
shift_sample = recording

# Sound exposure level: single-event level normalized to 1 s (LAE)
lae = sel(event, fs, weighting="A", calibration_factor=sensitivity)

# Daily noise dose (IEC 61252): exposure in Pa²·h and LEX,8h / LEP,d
E = sound_exposure(shift_sample, fs, duration_hours=8, calibration_factor=sensitivity)
lex = lex_8h(shift_sample, fs, duration_hours=8, calibration_factor=sensitivity)

lc_peak is verified against the one-cycle/half-cycle reference responses of IEC 61672-1:2013 Table 5, sel against the Table 4 LAE toneburst column, and the dose functions against the IEC 61252 anchors (3.2 Pa²h ↔ exactly 90 dB). lc_peak polyphase-oversamples the C-weighted signal by oversample (default 8) before taking the maximum, recovering the true inter-sample peak: a raw on-grid maximum under-reads sustained HF tones by up to ~1.15 dB (an 8 kHz tone at 48 kHz is only 6 samples/cycle). Set oversample=1 to detect the peak on the original sample grid. With duration_hours, the input is treated as a representative sample of that exposure period; without it, the input is the whole event.

SEL: comparing events of different duration #

A 4 s train pass-by and a 30 s one cannot be compared by their $L_{Aeq}$ alone — the longer event delivers more energy at the same level. The sound exposure level compresses the whole event energy into exactly one second:

$$ L_E = L_{eq,T} + 10\log_{10}\frac{T}{T_0}, \qquad T_0 = 1\ \text{s} $$

so events of any duration become directly comparable, and $N$ identical events sum as $+10\log_{10}N$. This is the building block of airport and railway noise models.

A vehicle pass-by level history with its Leq over the whole event and the equal-energy one-second SEL block

Noise dose: sound exposure and LEX,8h #

Occupational regulations limit the daily dose, not the level. IEC 61252 expresses it as sound exposure $E$ in pascal-squared-hours — the time integral of the squared A-weighted pressure — and the equivalent normalized 8 h level:

$$ E = \int_0^T p_A^2(t)\ dt \quad [\text{Pa}^2\text{h}], \qquad L_{EX,8h} = 10\log_{10}\frac{E}{8\ \text{h} \cdot p_0^2} $$

The anchor worth memorizing: 3.2 Pa²h ⇔ exactly 90 dB over 8 h (the CI suite enforces it). Half the dose is −3 dB; double duration at the same level is +3 dB.

Peak / event / dose parameters #

Function Key parameters Returns Standard anchor
lc_peak(x, fs, calibration_factor=1.0, dbfs=False) dbfs=True references full-scale peak (1.0), not RMS LCpeak [dB] IEC 61672-1 §5.13, Table 5 tone bursts
sel(x, fs, weighting=None, ...) weighting='A' gives LAE SEL [dB] IEC 61672-1 Table 4 (LAE column)
sound_exposure(x, fs, duration_hours=None, ...) duration_hours treats x as a sample of that period E [Pa²h] IEC 61252
lex_8h(x, fs, duration_hours=None, ...) same sampling semantics LEX,8h [dB] IEC 61252 (≡ LEP,d)

lex_8h rates one recording; assembling a full working day from task or job samples — with the normative ISO 9612 uncertainty budget — continues in Occupational Noise Exposure.

Environmental noise: Lden, Ldn and rating levels (ISO 1996-1) #

Regulatory noise assessment weights evenings and nights more heavily. lden() implements the day-evening-night level of ISO 1996-1:2016 (3.6.4: +5 dB evening, +10 dB night, default 12/4/8 h periods — adjustable, since countries define them differently), ldn() the day-night variant (3.6.5), and composite_rating_level() the general whole-day composite of clause 6.5 (Formulae 5-6) for arbitrary periods with source or character adjustments (Table A.1: e.g. +5 dB regular impulsive, +12 dB highly impulsive, +3 to +6 dB prominent tones):

from phonometry import lden, composite_rating_level

l = lden(63.2, 58.1, 51.4)                      # from LAeq per period
r = composite_rating_level([(63.2, 12, 0.0),    # day
                            (58.1, 4, 5.0),     # evening (+5)
                            (51.4, 8, 10.0)])   # night  (+10) == lden

Synthetic 24-hour urban LAeq profile with day, evening and night bands, the +5 and +10 dB weighted period levels and the resulting Lden

lden() / ldn() / composite_rating_level() parameters #

Function Key parameters Notes
lden(lday, levening, lnight, hours=(12, 4, 8)) period LAeq values [dB]; hours must sum to 24 +5 dB evening, +10 dB night (3.6.4)
ldn(lday, lnight, hours=(15, 9)) +10 dB night (3.6.5)
composite_rating_level(periods) iterable of (level_db, hours, adjustment_db); hours positive, finite and summing to 24 General Formulae (5)-(6); adjustments per Table A.1

Where you put the microphone changes the number: ISO 1996-2 fixes the receiver positions and their façade corrections:

Environmental noise measurement positions per ISO 1996-2: free field, 2 m from the facade and flush-mounted, with their corrections

Combine with laeq() per time period to go from recordings to Lden, and with the tone_to_noise_ratio() / prominence_ratio() verdicts of Prominent Discrete Tones to justify tonal adjustments.

Octave Spectrogram (levels over time) #

Short-time fractional-octave analysis: one level per band per window, time-aligned across bands.

from phonometry import OctaveFilterBank

bank = OctaveFilterBank(fs=48000, fraction=3)
levels, freq, times = bank.spectrogram(recording, window_time=0.125, overlap=0.5)
# levels: (bands, frames) — ready for pcolormesh(times, freq, levels)

One-third-octave spectrogram of a logarithmic sweep with two tone bursts

A logarithmic sweep plus two tone bursts, resolved in time and in standardized 1/3-octave bands.

  • Multichannel input (channels, samples) returns (channels, bands, frames).
  • times holds each window's center in seconds.
  • mode='peak' gives per-window peak-holding levels instead of RMS.
  • zero_phase=True filters bands forward-backward so per-band group delay does not skew the frames (offline analysis only).

OctaveFilterBank.spectrogram() parameters #

Parameter Type Units Range / default Notes
x 1D or 2D array digital units non-empty 2D returns (channels, bands, frames)
window_time float s > 0; default 0.125 Frame length (0.125 s mirrors Fast)
overlap float — 0 ≤ overlap < 1; default 0.5 Fraction of window overlap (0 = none)
mode str — 'rms' (default) or 'peak' Per-window detector
detrend bool — default True Remove each band's DC offset before the level (improves low-frequency accuracy)
zero_phase bool — default False Forward-backward filtering (offline only)
calibration_factor / dbfs — — constructor-only Set on OctaveFilterBank(...), not per call
import matplotlib.pyplot as plt

fig, ax = plt.subplots()
mesh = ax.pcolormesh(times, freq, levels, shading="auto")
ax.set_yscale("log")
ax.set_xlabel("Time [s]")
ax.set_ylabel("Frequency [Hz]")
fig.colorbar(mesh, label="Level [dB]")

See Calibration and dBFS to convert digital units to physical SPL, and Time Weighting for the envelope details. The ISO 9612 occupational strategies continue in Occupational Noise Exposure, the ECMA-418-1 tonal-prominence verdicts in Prominent Discrete Tones, and the ISO 226 equal-loudness contours live with the perception metrics in Psychoacoustics.