# Copyright (c) 2026. Jose Manuel Requena Plens """Audiometric test methods and the earmuff on its test fixture. ISO 8253-1:2010 (pure-tone air and bone conduction audiometry, read on BS EN ISO 8253-1:2010, where printed folio n is PDF page n + 8): the maximum permissible ambient sound pressure levels of Tables 2 and 4, the earphone attenuations of Table 3 and the uncertainty budget of Annex A. ISO 8253-2:2009 (sound field audiometry, printed folio n on PDF page n + 6): the ambient limits of Table 2, the microphone requirements of Table 1 and the off-axis increases of Table B.1. ISO 4869-3:2007 (the earmuff on an acoustic test fixture, printed folio n on PDF page n + 4): Table 1, Table A.1 and the uncertainty budget of Table B.1. Every value was read on the rasterized page, except :data:`ISO8253_2_BINAURAL_OFFSET_DB`, which the library derives from two of them. """ from __future__ import annotations import math # --------------------------------------------------------------------------- # ISO 8253-1:2010, Tables 2 to 4 (folios 17 to 19, PDF pages 25 to 27) # --------------------------------------------------------------------------- #: The one-third-octave mid-frequencies of Tables 2 to 4, in hertz. ISO8253_1_BANDS_HZ: tuple[float, ...] = ( 31.5, 40.0, 50.0, 63.0, 80.0, 100.0, 125.0, 160.0, 200.0, 250.0, 315.0, 400.0, 500.0, 630.0, 800.0, 1000.0, 1250.0, 1600.0, 2000.0, 2500.0, 3150.0, 4000.0, 5000.0, 6300.0, 8000.0, ) # fmt: skip #: Table 2: L_S,max for air conduction with supra-aural earphones, in dB, #: keyed by the lowest test tone frequency. ISO8253_1_TABLE_2: dict[float, tuple[float, ...]] = { 125.0: (56, 52, 47, 42, 38, 33, 28, 23, 20, 19, 18, 18, 18, 18, 20, 23, 25, 27, 30, 32, 34, 36, 35, 34, 33), 250.0: (66, 62, 57, 52, 48, 43, 39, 30, 20, 19, 18, 18, 18, 18, 20, 23, 25, 27, 30, 32, 34, 36, 35, 34, 33), 500.0: (78, 73, 68, 64, 59, 55, 51, 47, 42, 37, 33, 24, 18, 18, 20, 23, 25, 27, 30, 32, 34, 36, 35, 34, 33), } # fmt: skip #: Table 3: average sound attenuation of three earphones, in dB; the HDA 200 #: prints a dash below 63 Hz. ISO8253_1_TABLE_3: dict[str, tuple[float, ...]] = { "supra-aural": (0, 0, 0, 1, 1, 2, 3, 4, 5, 5, 5, 6, 7, 9, 11, 15, 18, 21, 26, 28, 31, 32, 29, 26, 24), "ER-3A": (33, 33, 33, 33, 33, 33, 33, 34, 35, 36, 37, 37, 38, 37, 37, 37, 35, 34, 33, 35, 37, 40, 41, 42, 43), "HDA 200": (math.nan, math.nan, math.nan, 17, 16, 15, 15, 15, 16, 16, 18, 20, 23, 25, 27, 29, 30, 31, 32, 37, 41, 46, 45, 45, 44), } # fmt: skip #: Table 4: L_S,max for bone conduction, in dB, keyed by the lowest test tone #: frequency. ISO8253_1_TABLE_4: dict[float, tuple[float, ...]] = { 125.0: (55, 47, 41, 35, 30, 25, 20, 17, 15, 13, 11, 9, 8, 8, 7, 7, 7, 8, 8, 6, 4, 2, 4, 9, 15), 250.0: (63, 56, 49, 44, 39, 35, 28, 21, 15, 13, 11, 9, 8, 8, 7, 7, 7, 8, 8, 6, 4, 2, 4, 9, 15), } # fmt: skip #: The NOTEs to Tables 2 and 4: a threshold shift of +5 dB instead of +2 dB #: raises every limit by this, in dB. ISO8253_1_RELAXED_ALLOWANCE_DB = 8.0 # --------------------------------------------------------------------------- # ISO 8253-1:2010, 6.2.3.2 and 8.4 (folios 9 and 13, PDF pages 17 and 21) # --------------------------------------------------------------------------- #: 8.4: the hearing level at which the vibrotactile threshold lies on average #: for a bone vibrator on the mastoid, in dB, keyed by frequency in hertz. ISO8253_1_VIBROTACTILE_DB: dict[float, float] = {250.0: 40.0, 500.0: 60.0, 1000.0: 70.0} #: 8.4 NOTE: for forehead placement the values are about this much lower. ISO8253_1_FOREHEAD_OFFSET_DB = 10.0 #: 6.2.3.2: a hearing level of this much or more calls for caution #: (cross-hearing). ISO8253_1_CROSS_HEARING_DB = 40.0 #: 6.2.3.2 Step 3: agreement to this much or less, and a change of this much #: or more that sends the test back to further frequencies. ISO8253_1_RETEST_AGREEMENT_DB = 5.0 ISO8253_1_RETEST_DISAGREEMENT_DB = 10.0 # --------------------------------------------------------------------------- # ISO 8253-1:2010, Annex A (folios 24 to 27, PDF pages 32 to 35) # --------------------------------------------------------------------------- #: A.3.3: the audiometer's standard uncertainty, air conduction up to 4 kHz, #: 5 dB steps, as printed. ISO8253_1_A33_EQUIPMENT_DB = 2.3 #: A.3.4: the transducer's standard uncertainty up to and above 4 kHz. ISO8253_1_A34_TRANSDUCER_DB = (2.9, 3.9) #: Table A.2: the four standard uncertainties of the example, in dB. ISO8253_1_TABLE_A2_COMPONENTS_DB = (2.5, 2.3, 2.9, 2.0) #: A.6: the combined standard uncertainty and the expanded one, rounded to #: the nearest full decibel. ISO8253_1_TABLE_A2_U_DB = 4.9 ISO8253_1_TABLE_A2_EXPANDED_DB = 10.0 # --------------------------------------------------------------------------- # ISO 8253-2:2009 (folios 7, 9 and 15; PDF pages 13, 15 and 21) # --------------------------------------------------------------------------- #: Table 2: the ambient limits for sound field audiometry, 31,5 Hz to #: 12,5 kHz, in dB, keyed by the lowest test tone frequency. ISO8253_2_BANDS_HZ: tuple[float, ...] = ISO8253_1_BANDS_HZ + (10000.0, 12500.0) ISO8253_2_TABLE_2: dict[float, tuple[float, ...]] = { 125.0: (52, 44, 38, 32, 27, 22, 17, 14, 12, 10, 8, 6, 5, 5, 4, 4, 4, 5, 5, 3, 1, -1, 1, 6, 12, 14, 15), 250.0: (60, 53, 46, 41, 36, 32, 25, 18, 12, 10, 8, 6, 5, 5, 4, 4, 4, 5, 5, 3, 1, -1, 1, 6, 12, 14, 15), } # fmt: skip #: Table 1: (front-to-random sensitivity index, allowable variation), dB. ISO8253_2_TABLE_1: tuple[tuple[float, float], ...] = ( (5.0, 5.0), (4.5, 4.5), (4.0, 4.0), ) #: Table B.1: the test frequencies and the increase at the nearer ear for #: 45 and 90 degrees of incidence, in dB. The rows start at 125 Hz although #: the paragraph above the table announces 200 Hz. ISO8253_2_TABLE_B1_HZ: tuple[float, ...] = ( 125.0, 160.0, 200.0, 250.0, 315.0, 400.0, 500.0, 630.0, 800.0, 1000.0, 1250.0, 1500.0, 1600.0, 2000.0, 2500.0, 3000.0, 3150.0, 4000.0, 5000.0, 6000.0, 6300.0, 8000.0, 10000.0, 12500.0, ) # fmt: skip ISO8253_2_TABLE_B1: dict[float, tuple[float, ...]] = { 45.0: (0.5, 1, 1, 1, 1.5, 2.5, 3, 3.5, 3.5, 4, 4, 3.5, 3.5, 3, 3.5, 5, 5, 4, 6, 7.5, 7.5, 5.5, 4.5, 1.5), 90.0: (1, 1.5, 1.5, 2, 2.5, 3.5, 4.5, 5, 5, 5.5, 6, 5, 4.5, 2, 2, 2.5, 2, -0.5, 4, 9.5, 10, 8.5, 6, 8), } # fmt: skip #: Footnote a to Table 2 says the sound-field limits are derived from ISO #: 8253-1 for binaural listening and prints no offset. Laid side by side, from #: 31,5 Hz to 8 kHz each is the bone-conduction limit of ISO 8253-1 Table 4 #: less this, in dB: an observation on the two transcribed tables, not a #: value the footnote prints. ISO8253_2_BINAURAL_OFFSET_DB = 3.0 # --------------------------------------------------------------------------- # ISO 4869-3:2007 (folios 4, 9 and 11; PDF pages 8, 13 and 15) # --------------------------------------------------------------------------- #: Table 1, read with the text of 5.2.2 for an index of exactly 5 dB. ISO4869_3_TABLE_1: tuple[tuple[float, float], ...] = ((5.0, 5.0), (4.0, 4.0)) #: Table A.1: the front-to-random sensitivity index of an ATF with a WS1P #: microphone, in dB. ISO4869_3_TABLE_A1: dict[float, float] = { 500.0: 1.7, 630.0: 2.2, 800.0: 2.8, 1000.0: 3.2, 1250.0: 4.6, 1600.0: 4.6, 2000.0: 6.3, 2500.0: 6.5, 3150.0: 5.9, 4000.0: 2.9, 5000.0: -0.6, 6300.0: 5.1, 8000.0: 5.9, } # fmt: skip #: Table B.1: the five standard uncertainties, open level, occluded level, #: fixture, sound field and equipment, in dB, and the combined value printed #: under it. ISO4869_3_TABLE_B1_COMPONENTS_DB = (0.5, 1.0, 0.3, 0.5, 0.2) ISO4869_3_TABLE_B1_U_DB = 1.3 #: B.4: the expanded uncertainty, U = 2u. ISO4869_3_B4_EXPANDED_DB = 2.6 #: 5.1.4: the least acoustic isolation of the fixture, as (first band, last #: band, isolation) in hertz and dB; "higher" runs to the top of the range. ISO4869_3_ISOLATION: tuple[tuple[float, float, float], ...] = ( (63.0, 250.0, 50.0), (315.0, 4000.0, 65.0), (5000.0, 8000.0, 55.0), )