← [Documentation index](README.md) # Integrated and Statistical Levels Environmental noise metrics computed directly from the raw (calibrated) signal. ## Leq and LAeq The equivalent continuous level integrates the squared pressure over the measurement time: $$ L_{eq} = 10\log_{10}\left(\frac{1}{T}\int_0^T \frac{p^2(t)}{p_0^2}\,dt\right) \text{ dB}, \qquad p_0 = 20\ \mu\text{Pa} $$ and $L_{Aeq}$ is the same integral after A-weighting the signal. $L_N$ is the level exceeded $N\,\%$ of the time — the $(100-N)$-th percentile of the time-weighted level distribution. ```python from phonometry import leq, laeq # Equivalent continuous level of the whole recording level = leq(signal, calibration_factor=sensitivity) # A-weighted Leq (the standard environmental noise metric) la = laeq(signal, fs, calibration_factor=sensitivity) ``` Both accept 1D signals (returning a scalar) or 2D `[channels, samples]` arrays (returning one level per channel), and support `dbfs=True` for digital full-scale analysis (calibration does not apply in dBFS mode). Why the *energy* mean and not the arithmetic mean of dB values? Because sound doses add as energy: two periods at 60 dB and 80 dB do not average to 70 dB — the 80 dB half dominates and $L_{eq}$ = 77 dB. Averaging decibels directly underestimates every fluctuating noise. $L_{eq}$ is the level of the *steady* sound carrying the same energy as the real, fluctuating one, which is why regulations are written in terms of it. ### `leq()` / `laeq()` parameters | Parameter | Type / shape | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D or 2D array | digital units (or Pa if calibrated) | non-empty | 2D is `[channels, samples]`; returns one level per channel | | `fs` | int | Hz | > 0 (`laeq` only) | `leq` needs no sample rate (pure RMS integral) | | `calibration_factor` | float | Pa per digital unit | default `1.0` | From `calculate_sensitivity()` | | `dbfs` | bool | — | default `False` | `True`: 0 dBFS = full-scale RMS sine; ignores calibration | ## Percentile levels (LN) `ln_levels` computes statistical levels from the time-weighted envelope: **L10** is the level exceeded 10 % of the time (event peaks), **L50** the median, **L90** the background level. ```python from phonometry import ln_levels stats = ln_levels(signal, fs, n=(10, 50, 90), weighting="A") print(f"LA10={stats[10]:.1f} LA50={stats[50]:.1f} LA90={stats[90]:.1f} dB") ``` Fast level history of fluctuating noise with the L10, L50 and L90 statistical levels marked *L10 tracks the event peaks, L50 the median level and L90 the background.* Options: `mode` selects the envelope ballistics (`'fast'`, `'slow'`, `'impulse'`), `weighting` applies A/C weighting first, and `calibration_factor`/`dbfs` behave as in `leq`. The integrator attack transient (~2τ) is discarded before taking percentiles. Formally, $L_N$ is the $(100-N)$-th percentile of the distribution of the time-weighted level: the recording is first turned into a level-vs-time envelope (Fast by default), and $L_{10}$ is the envelope value exceeded 10 % of the time. That makes the *ballistics choice part of the metric*: an $L_{10}$ from a Slow envelope is systematically lower than from a Fast one on impulsive noise, so regulations always name the time weighting. ### `ln_levels()` parameters | Parameter | Type / shape | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D or 2D array | digital units | non-empty | 2D returns per-channel dicts | | `fs` | int | Hz | > 0 | Needed by the envelope detector | | `n` | tuple of ints | % | default `(10, 50, 90)` | Any exceedance percentages, e.g. `(1, 5, 95)` | | `mode` | str | — | `'fast'` (default), `'slow'`, `'impulse'` | IEC 61672-1 ballistics of the envelope | | `weighting` | str or None | — | `'A'`, `'C'`, `'G'`, `'Z'`, `None` (default) | Frequency weighting before the envelope | | `calibration_factor` / `dbfs` | float / bool | — | as `leq` | Same semantics as in `leq()` | ## Peak, event and occupational metrics ```python from phonometry import lc_peak, sel, sound_exposure, lex_8h # C-weighted peak (IEC 61672-1 §5.13) - occupational action limits use this peak = lc_peak(signal, fs, calibration_factor=sensitivity) # Sound exposure level: single-event level normalized to 1 s (LAE) lae = sel(event, fs, weighting="A", calibration_factor=sensitivity) # Daily noise dose (IEC 61252): exposure in Pa²·h and LEX,8h / LEP,d E = sound_exposure(shift_sample, fs, duration_hours=8, calibration_factor=sensitivity) lex = lex_8h(shift_sample, fs, duration_hours=8, calibration_factor=sensitivity) ``` `lc_peak` is verified against the one-cycle/half-cycle reference responses of IEC 61672-1:2013 Table 5, `sel` against the Table 4 LAE toneburst column, and the dose functions against the IEC 61252 anchors (3.2 Pa²h ↔ exactly 90 dB). With `duration_hours`, the input is treated as a representative sample of that exposure period; without it, the input is the whole event. ### SEL: comparing events of different duration A 4 s train pass-by and a 30 s one cannot be compared by their $L_{Aeq}$ alone — the longer event delivers more energy at the same level. The **sound exposure level** compresses the *whole* event energy into exactly one second: $$ L_E = L_{eq,T} + 10\log_{10}\frac{T}{T_0}, \qquad T_0 = 1\ \text{s} $$ so events of any duration become directly comparable, and $N$ identical events sum as $+10\log_{10}N$. This is the building block of airport and railway noise models. A vehicle pass-by level history with its Leq over the whole event and the equal-energy one-second SEL block ### Noise dose: sound exposure and LEX,8h Occupational regulations limit the daily *dose*, not the level. IEC 61252 expresses it as **sound exposure** $E$ in pascal-squared-hours — the time integral of the squared A-weighted pressure — and the equivalent **normalized 8 h level**: $$ E = \int_0^T p_A^2(t)\,dt \quad [\text{Pa}^2\text{h}], \qquad L_{EX,8h} = 10\log_{10}\frac{E}{8\,\text{h} \cdot p_0^2} $$ The anchor worth memorizing: **3.2 Pa²h ⇔ exactly 90 dB over 8 h** (the CI suite enforces it). Half the dose is −3 dB; double duration at the same level is +3 dB. ### Peak / event / dose parameters | Function | Key parameters | Returns | Standard anchor | | :--- | :--- | :--- | :--- | | `lc_peak(x, fs, calibration_factor=1.0, dbfs=False)` | `dbfs=True` references full-scale *peak* (1.0), not RMS | LCpeak [dB] | IEC 61672-1 §5.13, Table 5 tone bursts | | `sel(x, fs, weighting=None, ...)` | `weighting='A'` gives LAE | SEL [dB] | IEC 61672-1 Table 4 (LAE column) | | `sound_exposure(x, fs, duration_hours=None, ...)` | `duration_hours` treats `x` as a sample of that period | E [Pa²h] | IEC 61252 | | `lex_8h(x, fs, duration_hours=None, ...)` | same sampling semantics | LEX,8h [dB] | IEC 61252 (≡ LEP,d) | ## Loudness level of pure tones (ISO 226:2023) The normal equal-loudness-level contours relate the SPL of a pure tone to its perceived *loudness level* in phons (the SPL of an equally loud 1 kHz tone). `equal_loudness_contour(phon)` evaluates ISO 226:2023 Formula (1) at the 29 preferred third-octave frequencies of Table 1, `loudness_level(spl, frequency)` is the exact inverse (Formula 2), and `hearing_threshold()` returns the threshold-of-hearing column: ```python from phonometry import equal_loudness_contour, loudness_level freqs, spl = equal_loudness_contour(40.0) # the classic 40-phon contour phon = loudness_level(73.0, 63.0) # 73 dB @ 63 Hz -> 40 phon ``` ISO 226:2023 normal equal-loudness-level contours from 20 to 90 phon with the hearing threshold curve Validity per clause 4.1: 20-90 phon (80 phon above 4 kHz); the implementation is verified against the Annex B tables in CI. Note this is the loudness of *pure tones* - loudness of arbitrary signals (ISO 532 sones) is a different, upcoming feature. ## Prominent discrete tones (ECMA-418-1) Tonal components in machinery noise are far more annoying than their level suggests. ECMA-418-1:2024 (referenced by ECMA-74 Annex D) gives two FFT-based methods to decide whether a discrete tone is *prominent*: `tone_to_noise_ratio()` compares the tone level with the masking noise in its critical band (clause 11), and `prominence_ratio()` compares the critical band centred on the tone with the two contiguous bands (clause 12). Both return a structured verdict against the frequency-dependent prominence criteria: ```python from phonometry import tone_to_noise_ratio, prominence_ratio tnr = tone_to_noise_ratio(x, fs) # highest peak, or tone_freq=... pr = prominence_ratio(x, fs, tone_freq=1000.0) print(tnr.ratio_db, tnr.criterion_db, tnr.prominent) ``` The methods hinge on the **critical band** — the ear's analysis bandwidth, $\Delta f_c = 25 + 75\,[1 + 1.4(f/1000)^2]^{0.69}$ Hz (162 Hz at 1 kHz): a tone is masked only by the noise *inside* its critical band, so both ratios compare the tone against exactly that noise, not the whole spectrum. Averaged spectrum of a tone in noise with the critical band shaded and the tone-to-noise ratio annotated against its prominence criterion A TNR above $8 + 8.33\log_{10}(1000/f_t)$ dB (8 dB from 1 kHz up) classifies the tone as *prominent*; the PR criterion is $9 + 10\log_{10}(1000/f_t)$ dB. Low frequencies get higher thresholds because wider relative bands mask more. Proximate secondary tones in the same critical band are combined per clause 11.6; for harmonic complexes assess each component (`tone_freq=`). Both methods work on Hann-windowed, RMS-averaged spectra and need no absolute calibration (the ratios are level differences). ### `tone_to_noise_ratio()` / `prominence_ratio()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D array | any (uncalibrated OK) | ≥ `fs/resolution_hz` samples | Ratios are level differences: calibration cancels out | | `fs` | int | Hz | > 0 | | | `tone_freq` | float, optional | Hz | 89.1–11 200; default `None` | `None` assesses the highest peak in the range of interest | | `resolution_hz` | float | Hz | > 0; default `1.0` | Tone band must stay within 15 % of the critical band (clause 11.2) | Both return a `ToneAssessment(frequency, ratio_db, criterion_db, prominent)`. ## Environmental noise: Lden, Ldn and rating levels (ISO 1996-1) Regulatory noise assessment weights evenings and nights more heavily. `lden()` implements the day-evening-night level of ISO 1996-1:2016 (3.6.4: +5 dB evening, +10 dB night, default 12/4/8 h periods — adjustable, since countries define them differently), `ldn()` the day-night variant (3.6.5), and `composite_rating_level()` the general whole-day composite of clause 6.5 (Formulae 5-6) for arbitrary periods with source or character adjustments (Table A.1: e.g. +5 dB regular impulsive, +12 dB highly impulsive, +3 to +6 dB prominent tones): ```python from phonometry import lden, composite_rating_level l = lden(63.2, 58.1, 51.4) # from LAeq per period r = composite_rating_level([(63.2, 12, 0.0), # day (58.1, 4, 5.0), # evening (+5) (51.4, 8, 10.0)]) # night (+10) == lden ``` Synthetic 24-hour urban LAeq profile with day, evening and night bands, the +5 and +10 dB weighted period levels and the resulting Lden ### `lden()` / `ldn()` / `composite_rating_level()` parameters | Function | Key parameters | Notes | | :--- | :--- | :--- | | `lden(lday, levening, lnight, hours=(12, 4, 8))` | period LAeq values [dB]; `hours` must sum to 24 | +5 dB evening, +10 dB night (3.6.4) | | `ldn(lday, lnight, hours=(15, 9))` | | +10 dB night (3.6.5) | | `composite_rating_level(periods)` | iterable of `(level_db, hours, adjustment_db)`; hours positive, finite and summing to 24 | General Formulae (5)-(6); adjustments per Table A.1 | Combine with `laeq()` per time period to go from recordings to Lden, and with `tone_to_noise_ratio()` / `prominence_ratio()` to justify tonal adjustments. ## Octave Spectrogram (levels over time) Short-time fractional-octave analysis: one level per band per window, time-aligned across bands. ```python from phonometry import OctaveFilterBank bank = OctaveFilterBank(fs=48000, fraction=3) levels, freq, times = bank.spectrogram(signal, window_time=0.125, overlap=0.5) # levels: (bands, frames) — ready for pcolormesh(times, freq, levels) ``` One-third-octave spectrogram of a logarithmic sweep with two tone bursts *A logarithmic sweep plus two tone bursts, resolved in time and in standardized 1/3-octave bands.* - Multichannel input `(channels, samples)` returns `(channels, bands, frames)`. - `times` holds each window's center in seconds. - `mode='peak'` gives per-window peak-holding levels instead of RMS. - `zero_phase=True` filters bands forward-backward so per-band group delay does not skew the frames (offline analysis only). ### `OctaveFilterBank.spectrogram()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D or 2D array | digital units | non-empty | 2D returns `(channels, bands, frames)` | | `window_time` | float | s | > 0; default `0.125` | Frame length (0.125 s mirrors Fast) | | `overlap` | float | — | 0 ≤ overlap < 1; default `0.5` | Fraction of window overlap (0 = none) | | `mode` | str | — | `'rms'` (default) or `'peak'` | Per-window detector | | `zero_phase` | bool | — | default `False` | Forward-backward filtering (offline only) | | `calibration_factor` / `dbfs` | — | — | constructor-only | Set on `OctaveFilterBank(...)`, not per call | ```python import matplotlib.pyplot as plt fig, ax = plt.subplots() mesh = ax.pcolormesh(times, freq, levels, shading="auto") ax.set_yscale("log") ax.set_xlabel("Time [s]") ax.set_ylabel("Frequency [Hz]") fig.colorbar(mesh, label="Level [dB]") ``` See [Calibration and dBFS](calibration.md) to convert digital units to physical SPL, and [Time Weighting](time-weighting.md) for the envelope details.