← [Documentation index](README.md) # Surface Scattering, Diffusion and In-situ Absorption How a surface returns incident sound — how much it scatters away from the specular direction, how uniformly it spreads what it scatters, and how much it absorbs — is measured by a family of dedicated methods. The **reverberation room** gives the random-incidence *scattering coefficient* of a surface by comparing decays with the sample held still and rotating (ISO 17497-1). A **free-field goniometer** measures the polar response of the reflected sound and condenses it into a *diffusion coefficient* (ISO 17497-2). And out on a road, a loudspeaker and a single microphone recover the *in-situ absorption* of the pavement, either over an extended surface by subtracting the incident wave (ISO 13472-1) or through a small tube pressed onto the surface (ISO 13472-2). This page covers all four. The scattering and diffusion coefficients answer different questions and are not interchangeable: scattering is *how much* energy leaves the specular direction; diffusion is *how evenly* the reflected energy is spread over angle. ## 1. Random-incidence scattering coefficient (ISO 17497-1) The scattering coefficient $s$ is the fraction of reflected energy that does **not** leave the surface in the specular direction. ISO 17497-1 measures it in a reverberation room from four reverberation-time situations: with the test sample mounted on a turntable and held **stationary**, and with the turntable **rotating** (which averages the phase-coherent specular reflection away), each with and without a reflecting base plate. ISO 17497-1 random-incidence scattering setup: a reverberation room with the test sample on a turntable, a rotating loudspeaker boom and a microphone, measuring reverberation time with the sample stationary (giving the random-incidence absorption) and rotating (giving the specular absorption), from which the scattering coefficient is derived **Absorption from reverberation time (Clause 6).** Each situation converts to a Sabine absorption coefficient with the standard's own air-attenuation term: $$ \alpha = 55.3\,\frac{V}{S}\left(\frac{1}{c_2 T_2} - \frac{1}{c_1 T_1}\right) - 4\,\frac{V}{S}\,(m_2 - m_1), $$ where $V$ is the room volume, $S$ the sample area, $T$ the reverberation time, $c$ the speed of sound (Eq. (2): $c = 343.2\sqrt{(273.15+t)/293.15}$) and $m$ the power attenuation coefficient of air. The **stationary** pair gives the random-incidence absorption $\alpha_s$ (Eq. (1)); the **rotating** pair gives the specular absorption $\alpha_{spec}$ (Eq. (4)). **Scattering coefficient (Eq. (5)).** The two combine into $$ s = \frac{\alpha_{spec} - \alpha_s}{1 - \alpha_s}. $$ A fully specular surface reflects all its non-absorbed energy in the specular direction, so $\alpha_{spec} = \alpha_s$ and $s = 0$; a strong diffuser sends energy everywhere, raising $\alpha_{spec}$ towards 1 and $s$ towards 1. ```python import phonometry as ph # Four reverberation-time situations reduced to two absorption coefficients. # alpha_s from the stationary pair (Eq. 1); alpha_spec from the rotating pair # (Eq. 4). V = 200 m^3, S = 10 m^2, c = 343.2 m/s throughout. alpha_s = ph.random_incidence_absorption(200.0, 10.0, c1=343.2, T1=8.0, c2=343.2, T2=6.0) alpha_spec = ph.specular_absorption_coefficient(200.0, 10.0, c3=343.2, T3=7.5, c4=343.2, T4=5.0) s = ph.scattering_coefficient(alpha_spec, alpha_s) # Eq. (5) print(round(float(alpha_s), 4)) # 0.1343 print(round(float(alpha_spec), 4)) # 0.2148 print(round(float(s), 4)) # 0.0931 ``` Over a full one-third-octave measurement, `scattering_coefficient_spectrum` pairs the per-band $\alpha_{spec}$ and $\alpha_s$ with their band centres and returns a plottable `ScatteringResult`: ```python import numpy as np import phonometry as ph # A 13-band measurement (250-4000 Hz): the random-incidence absorption alpha_s # (stationary sample) and the specular absorption alpha_spec (rotating # turntable). A diffuser scatters more with frequency, so s(f) rises. freqs = np.array([250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 4000], float) alpha_s = np.full_like(freqs, 0.10) alpha_spec = 0.11 + 0.75 * (np.log10(freqs / 250) / np.log10(4000 / 250)) result = ph.scattering_coefficient_spectrum(freqs, alpha_spec, alpha_s) print(np.round(result.scattering[[0, 6, 12]], 3)) # [0.011 0.428 0.844] result.plot() # s(f) on a log-frequency axis, 0 to 1 (needs matplotlib) ``` The random-incidence scattering coefficient s of a diffusing surface over the 13 one-third-octave bands from 250 to 4000 Hz, rising smoothly from near zero at low frequency towards 0.84 at 4 kHz *The scattering coefficient climbs with frequency: at low frequency the surface relief is small compared with the wavelength and the reflection stays specular ($s \to 0$); as the wavelength shrinks the relief scatters more energy out of the specular direction ($s \to 1$).*
Show the code for this figure ```python import matplotlib.pyplot as plt # result is the ScatteringResult computed above. One line: result.plot() plt.show() # By hand, from the result's fields, mirroring what ScatteringResult.plot() draws: fig, ax = plt.subplots() ax.semilogx(result.frequencies, result.scattering, "o-", color="#1f77b4") ax.set_xlabel("Frequency [Hz]") ax.set_ylabel("Scattering coefficient s") ax.set_ylim(0.0, 1.0) ax.set_title("Random-incidence scattering coefficient (ISO 17497-1)") plt.show() ```
**Base-plate check (Clause 6.4, Table 1).** The empty base plate must itself scatter only negligibly, or it would bias the result. ISO 17497-1 caps the base-plate scattering coefficient per one-third-octave band; the library exposes those limits and a checker. ```python from phonometry import ( BASE_PLATE_BANDS_HZ, BASE_PLATE_MAX_SCATTERING, check_base_plate_scattering, ) # The normative per-band ceilings (Table 1): 0.05 up to 500 Hz, rising to 0.25. # BASE_PLATE_BANDS_HZ is the band tuple; BASE_PLATE_MAX_SCATTERING maps band -> ceiling. print(BASE_PLATE_BANDS_HZ[0], BASE_PLATE_MAX_SCATTERING[100]) # 100 0.05 # A base plate whose measured scattering stays under the ceiling passes silently; # an over-limit band raises a ScatteringDiffusionWarning listing the offenders. check_base_plate_scattering([0.02] * len(BASE_PLATE_BANDS_HZ)) ``` ## 2. Diffusion coefficient (ISO 17497-2) The diffusion coefficient $d$ measures the **spatial uniformity** of the reflected sound, not how much is scattered. A goniometer sweeps a receiver over a polar arc and records the reflected level $L_i$ at each angle; the coefficient is the normalised autocorrelation of the polar energy distribution. ISO 17497-2 free-field diffusion goniometer: a test sample on a turntable, a fixed loudspeaker source, and a semicircular arc of receiver microphones sampling the reflected polar response, from which the autocorrelation diffusion coefficient is computed **Autocorrelation (Formula (5)).** For $n$ receivers at equal angular spacing, with $p_i = 10^{L_i/10}$ the band energy at receiver $i$, $$ d = \frac{\left(\sum_i p_i\right)^2 - \sum_i p_i^2} {(n-1)\,\sum_i p_i^2}. $$ A perfectly uniform polar response ($L_i$ all equal) gives $d = 1$; a single sharp specular lobe gives $d = 0$. When receivers subtend unequal solid angles, Formula (6) area-weights each energy by $N_i$ from Formula (8) — and those area factors are evaluated in **radians**, which is why a 5° spacing at the zenith produces a weight near 1.57, not 51.9. ```python import phonometry as ph # Polar response of a diffuser (levels in dB at equally spaced receivers). levels = [70.0, 74.0, 68.0, 72.0] d = ph.directional_diffusion_coefficient(levels) # Formula (5) print(round(float(d), 4)) # 0.7367 # Normalise against a flat reference surface to isolate the diffuser's effect # (Formula (7)): d_n = (d - d_ref) / (1 - d_ref). d_n = ph.normalized_diffusion_coefficient(d, 0.10) print(round(float(d_n), 4)) # 0.7075 # Random-incidence value: average the band coefficients over source positions, # with the standard's 2-D weighting (0 deg -> 1, +/-30/+/-60 deg -> 3). from phonometry import TWO_DIMENSIONAL_SOURCE_WEIGHTS d_random = ph.random_incidence_diffusion( [0.5, 0.2, 0.2, 0.2, 0.2], weights=TWO_DIMENSIONAL_SOURCE_WEIGHTS) print(round(float(d_random), 4)) # 0.2231 ``` `directional_diffusion` keeps the receiver angles beside the levels of a full goniometer sweep and returns a plottable `DiffusionResult`: ```python import numpy as np import phonometry as ph # A goniometer sweep of a diffusing surface: reflected levels L_i at 37 # receivers from -90 to 90 deg (5 deg spacing). The energy is spread almost # uniformly over angle, so the Formula (5) coefficient d is high. angles = np.arange(-90.0, 90.5, 5.0) rng = np.random.default_rng(3) levels = 70.0 + 2.0 * np.sin(np.radians(angles) * 3.0) + rng.normal(0.0, 1.0, angles.size) result = ph.directional_diffusion(angles, levels) print(round(result.coefficient, 2)) # 0.82 result.plot() # polar reflected response, d in the title (needs matplotlib) ``` A polar plot of the reflected sound-pressure level of a diffusing surface over 37 receivers from -90 to 90 degrees, the response spread almost uniformly over angle, giving an autocorrelation diffusion coefficient d of about 0.82 *The reflected energy fills the whole semicircle rather than concentrating in a specular lobe, so the autocorrelation diffusion coefficient is high ($d \approx 0.82$). A flat surface would collapse the response into a narrow spike and drive $d$ towards zero.*
Show the code for this figure ```python import matplotlib.pyplot as plt import numpy as np # result is the DiffusionResult computed above. One line: result.plot() plt.show() # By hand: a polar plot of the levels, with d annotated in the title. fig, ax = plt.subplots(subplot_kw={"projection": "polar"}) theta = np.radians(result.angles) ax.plot(theta, result.levels, "o-", color="#1f77b4") ax.fill(theta, result.levels, color="#1f77b4", alpha=0.15) ax.set_theta_zero_location("N") ax.set_theta_direction(-1) ax.set_thetamin(-90) ax.set_thetamax(90) ax.set_title(f"Directional diffusion d = {result.coefficient:.2f} (ISO 17497-2)") plt.show() ```
## 3. In-situ road absorption — subtraction technique (ISO 13472-1) Out in the field there is no reverberation room. ISO 13472-1 measures the sound absorption of a road surface (or any extended flat surface) *in situ* by firing an impulse from a loudspeaker at height $d_s$ down onto the surface and recording the impulse response at a microphone at height $d_m$. The **incident** and **reflected** components are separated in time with an Adrienne window; their transfer function gives the reflection factor and hence the absorption. ISO 13472-1 in-situ road absorption by the subtraction technique: a loudspeaker at 1.25 m and a microphone at 0.25 m above the road surface, with the direct and road-reflected ray paths and a free-field reference measurement, the reflected component isolated by an Adrienne time window **Geometrical spreading (Clause 4.1).** The reflected wave travels farther than the direct wave, so it is attenuated by the geometrical-spreading factor $$ K_r = \frac{d_s - d_m}{d_s + d_m}, $$ which equals $2/3$ for the mandatory geometry $d_s = 1.25$ m, $d_m = 0.25$ m. The absorption follows from the windowed incident and reflected spectra $H_i$, $H_r$: $$ \alpha(f) = 1 - \frac{1}{K_r^2}\left|\frac{H_r(f)}{H_i(f)}\right|^2. $$ ```python import numpy as np import phonometry as ph # A band-limited incident impulse response and a synthetic road reflection # hr = Kr * r0 * delayed(hi): a reflection of magnitude r0 = 0.4, delayed by the # extra path, and scaled by the geometrical-spreading factor Kr. fs, n = 48000.0, 4096 t = np.arange(n) / fs hi = np.zeros(n) hi[:64] = np.hanning(64) * np.cos(2.0 * np.pi * 1500.0 * t[:64]) kr = ph.geometric_spreading_factor() # (ds - dm)/(ds + dm) = 2/3 hr = kr * 0.4 * np.roll(hi, 96) # Narrow-band absorption, then reduced to one-third octaves over 250-4000 Hz. alpha = ph.insitu_absorption_coefficient(hi, hr) # 1 - (1/Kr^2)|Hr/Hi|^2 freq = np.fft.rfftfreq(n, 1.0 / fs) centres, band = ph.one_third_octave_absorption(freq, alpha) print(round(kr, 4)) # 0.6667 print(round(float(band[2]), 3)) # 0.84 (alpha = 1 - 0.4^2 = 0.84) ``` **Adrienne window (Clause 6.4).** The time window that isolates the reflection mandates only a sharp leading edge, a 5 ms flat portion and a cosine-squared or Blackman-Harris trailing edge — the exact durations are reported per measurement, not fixed, so they are configurable here. ```python from phonometry import adrienne_window # Default: 0.5 ms leading edge, 5 ms flat top, 5 ms Blackman-Harris trailing. w = adrienne_window(48000.0) print(w.shape[0]) # 504 samples at 48 kHz print(round(float(w.max()), 3)) # 1.0 (flat top and edges meet at unity) ``` **End-to-end spectrum.** `insitu_absorption_spectrum` runs the whole chain — the windowed incident and reflected impulse responses to the narrow-band absorption and on to one-third-octave bands — and returns a plottable `InsituAbsorptionResult`: ```python import numpy as np import phonometry as ph from scipy.signal import firwin, lfilter # A synthetic-but-realistic measurement. hi is a unit incident impulse; the road # reflection hr = Kr * r0 * roll(hi, shift) uses the geometrical-spreading # factor Kr, a mildly frequency-dependent r0 (a gentle low-pass, so a porous # surface reflects less as frequency rises) and the reflected-path delay # shift = round(2 dm / c * fs). fs, n = 48000.0, 8192 kr = ph.geometric_spreading_factor() # (ds - dm)/(ds + dm) = 2/3 hi = np.zeros(n) hi[0] = 1.0 taps = firwin(41, 1200.0, fs=fs) taps = taps / taps.sum() shift = int(round(2.0 * 0.25 / 340.0 * fs)) # reflected-path delay 2 dm / c hr = kr * 0.85 * np.roll(lfilter(taps, 1.0, hi), shift) result = ph.insitu_absorption_spectrum(hi, hr, fs) print(result.frequencies[[0, -1]].astype(int)) # [ 250 4000] print(np.round(result.absorption[[0, 6, 12]], 2)) # [0.31 0.65 1. ] result.plot() # alpha(f) bar chart over 250-4000 Hz (needs matplotlib) ``` An in-situ one-third-octave road-surface absorption spectrum computed by the reflection-factor route from a synthetic road reflection, rising from about 0.3 at 250 Hz to near 1.0 above 2 kHz *The absorption rises with frequency because the surface reflects less of the high-frequency energy, exactly as the low-pass reflection factor $r_0(f)$ dictates through $\alpha = 1 - (1/K_r^2)\,|H_r/H_i|^2$.*
Show the code for this figure ```python import matplotlib.pyplot as plt import numpy as np # result is the InsituAbsorptionResult computed above. One line: result.plot() plt.show() # By hand: a bar chart of alpha over the one-third-octave bands. freqs = result.frequencies positions = np.arange(freqs.size) fig, ax = plt.subplots() ax.bar(positions, np.nan_to_num(result.absorption), width=0.7, color="#1f77b4") ax.set_xticks(positions) ax.set_xticklabels([f"{f:g}" for f in freqs], rotation=45, ha="right") ax.set_xlabel("Frequency [Hz]") ax.set_ylabel("Absorption coefficient alpha") ax.set_ylim(0.0, 1.0) ax.set_title("In-situ road-surface absorption (ISO 13472-1)") plt.show() ```
**Maximum sampled area (Annex A).** The finite time window limits how much of the surface contributes to the reflection. The maximum sampled area is a circle whose radius the library computes from the geometry and window width; the Annex A worked example ($d_s = 1.25$ m, $d_m = 0.25$ m, $c = 340$ m/s, 5 ms flat window) gives about 1.34 m. ```python import phonometry as ph print(round(ph.max_sampled_area_radius(5.0e-3), 3)) # 1.343 (metres) ``` ## 4. In-situ road absorption — spot method (ISO 13472-2) For smaller patches, ISO 13472-2 seals a short circular tube onto the surface and measures the absorption with the two-microphone transfer-function method of ISO 10534-2. The library provides the spot-method geometry and validity helpers; the transfer-function DSP itself is the impedance-tube routine `two_microphone_impedance` (see [Acoustic Materials](materials.md)). ISO 13472-2 spot method: a short circular tube sealed onto the road surface with a loudspeaker at the top and two microphones flush in the tube wall at spacing s, measuring absorption over 250 to 1600 Hz via the ISO 10534-2 two-microphone transfer-function method **Plane-wave limits (Clause 5.4).** The tube supports only plane waves below $$ f_u = 0.58\,\frac{c_0}{d}, $$ with $d$ the tube diameter, and the microphone spacing $s$ must sit between $0.05\,c_0/f_{min}$ and $0.45\,c_0/f_{max}$. The reported range is the one-third-octave bands 250–1600 Hz. ```python import phonometry as ph # Upper usable frequency of a 100 mm tube and the valid spacing window. print(round(ph.spot_tube_upper_frequency(0.100, 343.0), 1)) # 1989.4 Hz s_min, s_max = ph.spot_microphone_spacing_bounds( 343.0, f_min=220.0, f_max=1800.0) print(round(s_min, 3), round(s_max, 3)) # 0.078 0.086 (metres) ``` --- **Standards implemented on this page:** ISO 17497-1:2004 (scattering coefficient), ISO 17497-2:2012 (diffusion coefficient), ISO 13472-1:2002 (in-situ absorption, extended surface), ISO 13472-2:2010 (in-situ absorption, spot method). Numerical conformance against the standards' worked examples and closed forms is tracked in [CONFORMANCE.md](CONFORMANCE.md).