← [Documentation index](README.md) # Psychoacoustics and Speech Intelligibility Level metrics tell you how much *sound pressure* there is; psychoacoustic metrics tell you what a listener actually *perceives*. This page covers loudness (ISO 532-1), sharpness (DIN 45692) and the speech transmission index (IEC 60268-16), then the advanced Moore-Glasberg (ISO 532-2/3) and Sottek Hearing Model (ECMA-418-2) loudness, tonality and roughness models. ## Loudness in sones (ISO 532-1, Zwicker) Decibels compress perception: 10 dB more reads as *twice as loud*, and two sounds with the same dB(A) can differ audibly depending on how their energy spreads over the ear's **critical bands**. The Zwicker method models the hearing chain explicitly — outer/middle-ear transmission, critical-band analysis on the 24 Bark scale, level-dependent masking slopes — and outputs **loudness N in sones**, a ratio scale: 4 sones is twice as loud as 2 sones. By definition a 1 kHz tone at 40 dB SPL is 1 sone, and every +10 phon doubles the sone value. Specific loudness patterns over the Bark scale for a 1 kHz narrowband sound and a broadband sound of equal band level *Same band level, very different loudness: energy spread over many critical bands (red) sums to far more sones than the same level concentrated in one band (blue). The area under N'(z) is the total loudness.* ```python import numpy as np from phonometry import loudness_zwicker, loudness_zwicker_from_spectrum # A raw recording plus its calibration so the guide runs standalone fs = 48000 x = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs) # any recording (digital units) sens = 1.0 # calibration_factor to pascals levels_28 = np.full(28, 60.0) # 28 one-third-octave band levels (dB) # From a raw recording: calibration_factor scales digital units to Pa res = loudness_zwicker(x, fs, field="free", calibration_factor=sens) print(f"N = {res.loudness:.1f} sone ({res.loudness_level:.0f} phon)") # Time-varying signals: percentile loudness N5 is the reporting standard res = loudness_zwicker(x, fs) # stationary=False (default) print(res.n5, res.n10, res.loudness) # N5, N10, Nmax # From 28 one-third-octave band levels (25 Hz .. 12.5 kHz) res = loudness_zwicker_from_spectrum(levels_28, field="diffuse") res.plot() # N'(z) over the Bark scale — the specific-loudness pattern (needs matplotlib) ```
Show the code for this figure ```python import matplotlib.pyplot as plt # One line — the specific-loudness pattern N'(z) straight from the result: res.plot() plt.show() # Or reproduce the figure by hand — two patterns of equal band level (60 dB), # energy spread over many critical bands vs concentrated in the 1 kHz band: narrow = loudness_zwicker_from_spectrum(np.r_[np.full(16, -60.0), 60.0, np.full(11, -60.0)]) broad = loudness_zwicker_from_spectrum(np.full(28, 60.0)) z = np.arange(1, narrow.specific.size + 1) * 0.1 # Bark axis fig, ax = plt.subplots() for r, color, label in [ (broad, "#ff7f0e", f"Broadband N = {broad.loudness:.1f} sone"), (narrow, "#1f77b4", f"1 kHz narrowband N = {narrow.loudness:.1f} sone"), ]: ax.fill_between(z, r.specific, color=color, alpha=0.3) ax.plot(z, r.specific, color=color, label=label) ax.set_xlabel("Critical-band rate z [Bark]") ax.set_ylabel("Specific loudness N' [sone/Bark]") ax.legend() plt.show() ```
The implementation is a clean-room port of the standard's **normative reference program** (Annex A.4): all twelve data tables are digit-exact and the full Annex B validation set runs in CI — the stationary test case reproduces the published value to every printed digit, and the tone-pulse N(t) traces stay inside the standard's per-sample 5 % tolerance band. ### `loudness_zwicker()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D array | Pa (after calibration) | ≥ 8 ms at 48 kHz | Resampled internally to 48 kHz if needed | | `fs` | int | Hz | > 0 | | | `field` | str | — | `'free'` (default) / `'diffuse'` | Sound-field correction (Table A.5) | | `stationary` | bool | — | default `False` | `True`: single N from the averaged spectrum | | `calibration_factor` | float | Pa per digital unit | default `1.0` | From `calculate_sensitivity()` | Returns a `ZwickerLoudness` dataclass: `loudness` (N, sones), `loudness_level` (phon), `specific` (N′(z), 240 bins of 0.1 Bark), and for time-varying runs `n5`, `n10`, `time`, `loudness_vs_time` (500 Hz trace). ## Sharpness in acum (DIN 45692) Two sounds can be equally loud yet one feels "sharper" — hissy, metallic — because its loudness sits higher on the Bark scale. Sharpness is the g(z)-weighted first moment of the specific loudness pattern: $$ S = k\ \frac{\int_0^{24} N'(z)\ g(z)\ z\ dz}{\int_0^{24} N'(z)\ dz}\ \text{acum} $$ with $g(z) = 1$ up to 15.8 Bark and rising exponentially beyond, and $k$ normalized so the reference sound — critical-band-wide noise at 1 kHz, 60 dB — is exactly **1.00 acum** (DIN 45692 clause 6; the derived $k = 0.108$ sits inside the normative window 0.105–0.115). DIN 45692 sharpness weighting g(z) against critical-band rate on a log axis, comparing the DIN, von Bismarck and Aures curves with the 15.8 and 15 Bark knees marked ```python from phonometry import sharpness_din s = sharpness_din(x, fs, calibration_factor=sens) # acum s_aures = sharpness_din(x, fs, method="aures") # Annex B variant ``` CI verifies the Table A.2 target values (0.38 acum at 250 Hz up to 2.82 acum at 4 kHz) within the standard's 5 % / 0.05 acum tolerance. ## Speech Transmission Index (IEC 60268-16) Reverberation and noise do not muffle speech uniformly — they blur its *envelope*: the slow (0.63–12.5 Hz) intensity modulations that carry syllables. STI quantifies how much of that modulation survives from mouth to ear, per octave band, as the **modulation transfer function** m(F). A delta-like channel keeps m = 1 (STI = 1); reverberation low-passes the envelope following Schroeder's closed form, and steady noise scales it: $$ m(F) = \frac{1}{\sqrt{1 + \left(2\pi F\ \frac{T_{60}}{13.8}\right)^2}} \cdot \frac{1}{1 + 10^{-\mathrm{SNR}/10}} $$ STI versus reverberation time with the IEC 60268-16 Annex F rating bands shaded STI measurement chain: STIPA source signal through the room to the microphone and the MTF analysis ```python import numpy as np from phonometry import sti_from_impulse_response, stipa, stipa_signal fs = 48000 # A measured room impulse response (synthesized decay so the example runs) ir = np.random.default_rng(0).standard_normal(fs) * np.exp(-6.9 * np.arange(fs) / fs / 0.5) # Indirect method: from a measured room impulse response res = sti_from_impulse_response(ir, fs, snr=25.0) print(f"STI = {res.sti:.2f} ({res.rating})") # e.g. 0.62 (D) # Direct STIPA measurement: play stipa_signal() in the room, record it test = stipa_signal(fs, seconds=18.0, level_db=80.0) recording = test # in practice, the microphone signal after playback res = stipa(recording, fs) res.plot() # per-band modulation transfer index (MTI) bars, STI + rating in the title ```
Show the code for this figure ```python import matplotlib.pyplot as plt # STI vs reverberation time: sweep sti_from_impulse_response over synthetic # exponential decays (white noise x exp(-6.9077 t / T60)) at a T60 grid — # exactly the physics behind the curve above: rng = np.random.default_rng(0) t60_grid = np.array([0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, 4.0, 5.0]) sti_values = [] for t60 in t60_grid: t = np.arange(int(2 * t60 * fs)) / fs ir = rng.standard_normal(t.size) * np.exp(-6.9077 * t / t60) sti_values.append(sti_from_impulse_response(ir, fs).sti) fig, ax = plt.subplots() ax.semilogx(t60_grid, sti_values, "o-") ax.set_xlabel("Reverberation time T60 [s]") ax.set_ylabel("STI") ax.set_ylim(0.0, 1.0) ax.grid(True, which="both", alpha=0.3) plt.show() ```
`stipa` emits a `UserWarning` when the recording is shorter than the recommended 15 s (IEC 60268-16 STIPA practice, 15 s to 25 s): below that the slow modulation components are averaged over too few periods and the STI is biased low (an ideal loopback gives STI ≈ 0.944 at 5 s vs ≈ 0.998 at 18 s). The implementation follows **Edition 5 (2020)**: Edition 4's normative PDF is the base and every Ed. 5 change is source-attributed in the code — the only numeric delta is the revised male speech spectrum of clause A.6.1. CI checks the standard's own verification vectors: the six weighting-factor band pairs to ±0.001 STI, the m ↔ STI mapping table, the level-dependent masking control points, and Schroeder-form decays at four T₆₀ values. ### `sti_from_impulse_response()` / `stipa()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `ir` / `x` | 1D array | any / Pa | non-empty | IR (indirect) or STIPA recording (direct) | | `fs` | int | Hz | > 0 | | | `snr` | float or 7-vector, optional | dB | default `None` | Adds steady-noise degradation | | `level` | 7-vector, optional | dB SPL | default `None` | Enables auditory masking + reception threshold (Tables A.2/A.3) | | `ambient` | 7-vector, optional | dB SPL | needs `level` | Ambient noise band levels | | `reference` | 1D array, optional (`stipa`) | — | default `None` | Measured source signal instead of the nominal m = 0.55 | Both return `STIResult`: `sti`, `mti` (7 bands), `mtf` (7×14 or 7×2), `band_levels`, `rating` (Annex F letter `A+`…`U`). ## Advanced loudness & sound-quality models ISO 532-1 above is one of **three** loudness models phonometry ships, and loudness is only half of the sound-quality story: two sounds of equal loudness can still differ in how *tonal* or how *rough* they are. This section adds the **Moore-Glasberg** loudness of ISO 532-2/532-3 and the **Sottek Hearing Model** loudness, tonality and roughness of ECMA-418-2:2025. ### Choosing a loudness model | Model | Standard | Stationary / time-varying | Output | When to use | | :--- | :--- | :--- | :--- | :--- | | Zwicker | ISO 532-1:2017 | both | sone | Reference method; one-third-octave input; fast and widely cited | | Moore-Glasberg | ISO 532-2:2017 | stationary | sone | roex excitation pattern; better for tones and explicit binaural summation | | Moore-Glasberg-Schlittenlacher | ISO 532-3:2023 | time-varying | sone (STL/LTL) | Time-varying loudness with short-/long-term traces and the peak N_max | | Sottek (Hearing Model) | ECMA-418-2:2025 | time-varying | sone_HMS | Shares one auditory front-end with the ECMA tonality and roughness metrics | All three are anchored so a **1 kHz tone at 40 dB SPL is ≈ 1 sone**; the values are not interchangeable digit-for-digit because the models differ in their auditory filters and their loudness summation. Loudness of a 1 kHz tone as a function of level for the Zwicker, Moore-Glasberg and Sottek models, all passing through 1 sone at 40 dB SPL *The three models agree at the 1 sone / 40 dB anchor and diverge with level: Zwicker doubles the sone value every +10 phon, while the Sottek model grows more slowly (about 1.65× per 10 dB), an intrinsic difference between the auditory summations, not a calibration error.* ### Moore-Glasberg loudness (ISO 532-2) Where Zwicker uses fixed critical bands on the Bark scale, Moore-Glasberg builds an **excitation pattern** with level-dependent rounded-exponential (roex) auditory filters on the ERB-number ("Cam") scale, then applies a compressive excitation → specific-loudness transform with C = 0.0617 sone/Cam (ISO 532-2:2017, Formula 7) and a binaural-inhibition stage. It reproduces the tone and broadband cases of Annex B to a percent or two and, unlike ISO 532-1, models binaural summation explicitly. ```python import numpy as np from phonometry import ( loudness_moore_glasberg, loudness_moore_glasberg_from_spectrum, ) # The definitional anchor: one 1 kHz sinusoidal component at 40 dB SPL, # free field, binaural -> 1 sone / 40 phon by construction of the sone. res = loudness_moore_glasberg_from_spectrum([(1000.0, 40.0)], field="free") print(f"N = {res.loudness:.3f} sone ({res.loudness_level:.1f} phon)") # 1.000 sone (40.0 phon) # From a calibrated recording: the narrowband (FFT) line spectrum is formed # (power-preserving normalization) and fed to the exact sinusoidal-component # method (ISO 532-2 clauses 5.2/5.4). fs = 48000 x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs) res = loudness_moore_glasberg(x, fs, field="free", presentation="binaural") res.plot() # specific loudness N'(i) over the ERB-number (Cam) scale ```
Show the code for this figure ```python import matplotlib.pyplot as plt # One line — the specific-loudness pattern N'(i) straight from the result: res.plot() plt.show() # Or draw it by hand from the ERB-number grid the result already carries: fig, ax = plt.subplots() ax.fill_between(res.erb_number, res.specific, alpha=0.3) ax.plot(res.erb_number, res.specific) ax.set_xlabel("ERB number [Cam]") ax.set_ylabel("Specific loudness N' [sone/Cam]") plt.show() ```
#### `loudness_moore_glasberg()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `x` | 1D array | Pa | non-empty | Calibrated pressure signal (signal wrapper) | | `components` | list of `(f, L)` | Hz, dB SPL | — | `_from_spectrum`: discrete sinusoidal components | | `band_levels` | 29-vector | dB SPL | 25 Hz .. 16 kHz | `_from_third_octave` input (IEC 61260-1 bands) | | `fs` | int | Hz | > 0 | Signal wrapper only | | `field` | str | — | `'free'` (default) / `'diffuse'` / `'eardrum'` | Outer-ear transfer | | `presentation` | str | — | `'binaural'` (default) / `'diotic'` / `'monaural'` | Binaural summation | Returns a `MooreGlasbergLoudness`: `loudness` (N, sone), `loudness_level` (phon), `specific` (N′(i), 372 bins of 0.1 Cam), `erb_number`, `centre_frequencies`, `field`, `presentation`. ### Time-varying loudness (ISO 532-3) ISO 532-3 wraps the same excitation / specific-loudness model in a running multi-resolution spectral analysis (six parallel FFTs, updated every 1 ms) and two cascaded temporal integrators: the fast **short-term loudness** S′(t) and the slower **long-term loudness** S″(t). The peak long-term loudness N_max predicts the loudness of sounds up to about 5 s. ```python import numpy as np from phonometry import loudness_moore_glasberg_time fs = 32000 t = np.arange(int(1.3 * fs)) / fs x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t) res = loudness_moore_glasberg_time(x, fs, field="free") print(f"N_max = {res.n_max:.3f} sone ({res.loudness_level_max:.0f} phon)") # 1.000 sone (40 phon) print(f"long-term loudness exceeded 5% of the time: {res.percentiles[5.0]:.3f} sone") res.plot() # short-term S'(t) and long-term S''(t) loudness vs time ``` Short-term and long-term Moore-Glasberg loudness traces for a tone burst, showing the fast attack of the short-term loudness and the slower release of the long-term loudness
Show the code for this figure ```python import matplotlib.pyplot as plt # The result carries both traces on a 1 ms time axis: res.plot() plt.show() # Or plot them directly to see the fast STL vs the slow LTL: fig, ax = plt.subplots() ax.plot(res.time, res.short_term_loudness, label="Short-term S'(t)") ax.plot(res.time, res.long_term_loudness, label="Long-term S''(t)") ax.set_xlabel("Time [s]") ax.set_ylabel("Loudness [sone]") ax.legend() plt.show() ```
#### `loudness_moore_glasberg_time()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `signal` | 1D or `(n, 2)` array | Pa | non-empty | Mono = diotic; two columns = left/right ears | | `fs` | int | Hz | > 0 | | | `field` | str | — | `'free'` (default) / `'diffuse'` / `'eardrum'` | Outer-ear transfer | | `presentation` | str | — | `'binaural'` (default) / `'diotic'` / `'monaural'` | Binaural summation | | `percentiles` | sequence | percent | default `(1, 5, 10, 50, 90, 95)` | Exceeded long-term loudness levels | Returns a `MooreGlasbergTimeVaryingLoudness`: `time` (1 ms grid), `short_term_loudness` / `long_term_loudness` (sone), their `_level` in phon, `n_max`, `loudness_level_max`, a `percentiles` dict, `field`, `presentation`. ### Sottek Hearing Model loudness (ECMA-418-2) ECMA-418-2:2025 specifies a single auditory front-end — outer/middle-ear filtering, a 53-band gammatone-like filter bank on the Bark_HMS scale (z = 0.5 .. 26.5), half-wave rectification, block RMS and a compressive nonlinearity (Formula 23) — that is **shared** by its loudness, tonality and roughness metrics. The loudness N is reported in **sone_HMS**, and the same 1 kHz/40 dB anchor calibrates the front-end (our clean-room value 0.996). ```python import numpy as np from phonometry import loudness_ecma fs = 48000 t = np.arange(int(1.2 * fs)) / fs x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t) res = loudness_ecma(x, fs, field="free") print(f"N = {res.loudness:.3f} sone_HMS") # 0.996 sone_HMS print(res.specific_loudness.shape) # (53,) average specific loudness N'(z) res.plot() # average specific loudness N'(z) + time-dependent N(l) at 187.5 Hz ``` Sottek Hearing Model average specific loudness N'(z) over the 53 Bark_HMS bands for a 1 kHz tone, peaking at the tone's critical band
Show the code for this figure ```python import matplotlib.pyplot as plt # The result carries the average specific loudness over the 53 Bark_HMS bands: res.plot() plt.show() # Or draw N'(z) by hand against the critical-band-rate scale: fig, ax = plt.subplots() ax.fill_between(res.bark, res.specific_loudness, alpha=0.3) ax.plot(res.bark, res.specific_loudness) ax.set_xlabel("Critical-band rate z [Bark_HMS]") ax.set_ylabel("Specific loudness N' [sone_HMS/Bark_HMS]") plt.show() ```
#### `loudness_ecma()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `signal_in` | 1D array | Pa | non-empty | Calibrated pressure signal | | `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed (Clause 5.1.1) | | `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter (Clause 5.1.3) | Returns an `EcmaLoudness`: `loudness` (N, sone_HMS), `specific_loudness` (N′(z), 53 bands), `bark`, `centre_frequencies`, `time`, `loudness_vs_time` (N(l) at 187.5 Hz), `field`. ### Tonality (ECMA-418-2) A tonal component — a whistle, a fan's blade-passing tone — stands out even at low level. ECMA-418-2 quantifies it from the **autocorrelation function** (ACF) of each band's rectified signal: a periodic (tonal) component keeps a high ACF at nonzero lag, and the tonal-to-noise loudness ratio drives the specific tonality T′(z). The single value T is in **tu_HMS**, calibrated so a 1 kHz/40 dB tone is ≈ 1 tu_HMS; the result also tracks the tonal frequency f_ton per band. ```python import numpy as np from phonometry import tonality_ecma fs = 48000 t = np.arange(int(1.2 * fs)) / fs x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t) res = tonality_ecma(x, fs, field="free") peak = int(np.argmax(res.specific_tonality)) print(f"T = {res.tonality:.3f} tu_HMS") # 1.000 tu_HMS print(f"f_ton = {res.tonal_frequencies[peak]:.0f} Hz") # 999 Hz res.plot() # average specific tonality T'(z) + time-dependent T(l) ``` #### `tonality_ecma()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `signal_in` | 1D array | Pa | non-empty | Calibrated pressure signal | | `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed | | `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter | | `f_low` | float, optional | Hz | default `None` | Lower edge of a user band for the T(l) search | | `f_high` | float, optional | Hz | default `None` | Upper edge of the user band | Returns an `EcmaTonality`: `tonality` (T, tu_HMS), `specific_tonality` (T′(z), 53 bands), `bark`, `centre_frequencies`, `tonal_frequencies` (f_ton,z), `time`, `tonality_vs_time` (T(l)), `tonal_frequency_vs_time`, `field`. ### Roughness (ECMA-418-2) — new capability Roughness is the harsh, buzzing sensation of fast amplitude modulation (roughly 20–300 Hz, peaking near 70 Hz) — the quality of a diesel idle or a distorted loudspeaker. It is a **new metric** for phonometry. ECMA-418-2 extracts each band's envelope, weights its modulation spectrum by modulation rate and depth, and correlates the modulation across bands; the result R is in **asper**. The reference sound (1 kHz carrier, 100 % amplitude-modulated at 70 Hz, 60 dB SPL) is defined as 1 asper — this clean-room implementation returns 1.0735 asper (about +7 %), an honest variance: the tabulated calibration constant c_R (Formula 104) is used **without** reverse-fitting to the target. ```python import numpy as np from phonometry import roughness_ecma fs = 48000 t = np.arange(int(2.0 * fs)) / fs carrier = np.sin(2 * np.pi * 1000 * t) amp = np.sqrt(2) * 2e-5 * 10 ** (60 / 20) # 60 dB SPL carrier x = amp * (1.0 + np.cos(2 * np.pi * 70 * t)) * carrier # 100 % AM at 70 Hz res = roughness_ecma(x, fs, field="free") print(f"R = {res.roughness:.4f} asper") # 1.0735 asper (reference target 1.0) res.plot() # time-dependent roughness R(l50) + specific-roughness heatmap ``` ECMA-418-2 sound-quality demo: a tonal sound scores high tonality and near-zero roughness, while a 70 Hz amplitude-modulated sound scores high roughness and low tonality
Show the code for this figure ```python import matplotlib.pyplot as plt import numpy as np from phonometry import tonality_ecma, roughness_ecma fs = 48000 t = np.arange(int(2.0 * fs)) / fs amp = np.sqrt(2) * 2e-5 * 10 ** (60 / 20) # A pure tone (tonal, smooth) vs a 70 Hz amplitude-modulated tone (rough): tone = amp * np.sin(2 * np.pi * 1000 * t) rough = amp * (1.0 + np.cos(2 * np.pi * 70 * t)) * np.sin(2 * np.pi * 1000 * t) scores = { "Pure tone": (tonality_ecma(tone, fs).tonality, roughness_ecma(tone, fs).roughness), "70 Hz AM tone": (tonality_ecma(rough, fs).tonality, roughness_ecma(rough, fs).roughness), } labels = list(scores) tonal = [scores[k][0] for k in labels] rough_v = [scores[k][1] for k in labels] xpos = np.arange(len(labels)) fig, ax = plt.subplots() ax.bar(xpos - 0.2, tonal, 0.4, label="Tonality [tu_HMS]") ax.bar(xpos + 0.2, rough_v, 0.4, label="Roughness [asper]") ax.set_xticks(xpos) ax.set_xticklabels(labels) ax.legend() plt.show() ```
#### `roughness_ecma()` parameters | Parameter | Type | Units | Range / default | Notes | | :--- | :--- | :--- | :--- | :--- | | `signal_in` | 1D array | Pa | non-empty | Calibrated pressure signal | | `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed | | `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter | Returns an `EcmaRoughness`: `roughness` (R, asper, the 90th percentile of R(l50)), `specific_roughness` (R′(z), 53 bands), `bark`, `centre_frequencies`, `time`, `roughness_vs_time` (R(l50)), `specific_roughness_vs_time` ((n_times, 53) array), `field`. See [Levels](levels.md) for tonality metrics and [Theory](theory.md) for the underlying math.