[](https://pypi.org/project/phonometry/)
[](https://pypi.org/project/phonometry/)
[](https://github.com/jmrplens/phonometry/blob/main/LICENSE)
[](https://github.com/jmrplens/phonometry/actions/workflows/python-app.yml)
[](https://sonarcloud.io/summary/overall?id=jmrplens_phonometry)
[](https://codecov.io/gh/jmrplens/phonometry)
[](https://doi.org/10.5281/zenodo.21215280)
# phonometry
> *phonometry* — the measurement of sound. Formerly published as **PyOctaveBand**.
Acoustic measurement toolkit for Python: fractional octave-band filter banks, frequency and time weighting, and sound level metrology — conformance-tested against **IEC 61260-1:2014 / ANSI S1.11-2004** (filters) and **IEC 61672-1:2013** (weighting and levels) class 1 tolerance limits.
## ✨ Highlights
- 🎛️ 1/1, 1/3 and arbitrary fractional octave filter banks (stable SOS + multirate decimation)
- 🏗️ Five architectures: Butterworth, Chebyshev I/II, Elliptic, Bessel — all with −3 dB points on the ANSI band edges
- 🔊 A/C/Z frequency weighting within IEC 61672-1 class 1 tolerances
- ⏱️ Fast/Slow/Impulse time ballistics, `Leq`, `LAeq` and `L10/L50/L90` statistical levels
- 🗺️ Octave spectrogram (band levels over time) and zero-phase offline filtering
- 🧠 Loudness in sones three ways: Zwicker (ISO 532-1 Annex B validated), Moore-Glasberg stationary & time-varying (ISO 532-2/3) and Sottek Hearing Model (ECMA-418-2); DIN 45692 sharpness, ISO 226:2023 contours
- 🎻 Sound-quality metrics: ECMA-418-2 tonality (tu_HMS) and roughness (asper)
- 🗣️ Speech Transmission Index: STI and STIPA per IEC 60268-16 Ed. 5, with signal generator
- 🎯 Tone prominence (TNR/PR, ECMA-418-1), environmental Lden/Ldn (ISO 1996-1), IEC 61252 noise dose
- ↗️ Two-microphone sound intensity (IEC 61043) with ISO 9614-1 field indicators
- 🏛️ Room & building acoustics: swept-sine/MLS impulse responses (ISO 18233), EDT/T20/T30/C50/C80/Ts (ISO 3382-1/2), open-plan speech metrics (ISO 3382-3), field airborne + impact + façade insulation with R′w/DnT,w/L′nT,w/D2m,nT,w and C/Ctr/CI (ISO 16283-1/2/3, ISO 717-1/2), laboratory R/Ln (ISO 10140), flanking-transmission prediction of R′w/L′n,w (EN 12354-1/2), measurement uncertainty (ISO 12999-1), sound absorption (ISO 354)
- 🌬️ Outdoor propagation & occupational exposure: atmospheric absorption α(f) (ISO 9613-1), the ISO 9613-2 general method (divergence + atmospheric + ground + barrier terms) with a per-term octave-band breakdown, and daily noise exposure LEX,8h with task/job/full-day strategies and Annex C uncertainty (ISO 9612)
- 🔊 Sound power LW three ways: enveloping-surface pressure (ISO 3744/3746), reverberation-room precision with Waterhouse/C1/C2 (ISO 3741), intensity scanning with field indicators and grade (ISO 9614-2)
- 📏 Physical SPL calibration with IEC 60942:2017 stability validation, and dBFS modes
- ⚡ Vectorized multichannel processing and stateful block (real-time) workflows
## 🚀 Installation
```bash
pip install phonometry
```
Optional extras: `phonometry[plot]` (matplotlib for response plots and result `.plot()` methods), `phonometry[perf]` (numba for faster impulse ballistics), `phonometry[full]` (both).
## 📚 Documentation
**Full documentation website: https://jmrplens.github.io/phonometry/** (English / Español)
Or browse the Markdown docs on GitHub:
| Page | Contents |
| :--- | :--- |
| [Getting Started](https://github.com/jmrplens/phonometry/blob/main/docs/getting-started.md) | Installation, first analysis, WAV files |
| [Filter Banks](https://github.com/jmrplens/phonometry/blob/main/docs/filter-banks.md) | Architectures, response gallery, band decomposition, zero-phase |
| [Frequency Weighting](https://github.com/jmrplens/phonometry/blob/main/docs/weighting.md) | A/C/Z curves, class 1 high-accuracy mode |
| [Time Weighting](https://github.com/jmrplens/phonometry/blob/main/docs/time-weighting.md) | Fast/Slow/Impulse ballistics, initial state |
| [Levels](https://github.com/jmrplens/phonometry/blob/main/docs/levels.md) | Leq, LAeq, percentiles, LCpeak, SEL, noise dose, occupational exposure strategies and uncertainty (ISO 9612), Lden, tonality, octave spectrogram |
| [Psychoacoustics](https://github.com/jmrplens/phonometry/blob/main/docs/psychoacoustics.md) | Zwicker (ISO 532-1), Moore-Glasberg (ISO 532-2/3) and Sottek (ECMA-418-2) loudness, sharpness (DIN 45692), tonality & roughness (ECMA-418-2), STI/STIPA (IEC 60268-16) |
| [Sound Intensity](https://github.com/jmrplens/phonometry/blob/main/docs/intensity.md) | Two-microphone p-p intensity (IEC 61043), ISO 9614-1 field indicators |
| [Room & Building Acoustics](https://github.com/jmrplens/phonometry/blob/main/docs/room-acoustics.md) | Impulse responses (ISO 18233), room parameters (ISO 3382-1/2), open-plan metrics (ISO 3382-3), field airborne + impact + façade insulation and weighted ratings (ISO 16283-1/2/3, ISO 717-1/2), laboratory characterisation (ISO 10140), flanking-transmission prediction (EN 12354-1/2), measurement uncertainty (ISO 12999-1), sound absorption (ISO 354) |
| [Outdoor Sound Propagation](https://github.com/jmrplens/phonometry/blob/main/docs/outdoor-propagation.md) | Atmospheric absorption α(f) (ISO 9613-1) and the ISO 9613-2 general method: geometrical divergence, atmospheric absorption, ground effect, barrier screening and meteorological correction |
| [Sound Power](https://github.com/jmrplens/phonometry/blob/main/docs/sound-power.md) | Sound power level LW by enveloping surface (ISO 3744/3746), reverberation room (ISO 3741) and intensity scanning (ISO 9614-2) |
| [Calibration and dBFS](https://github.com/jmrplens/phonometry/blob/main/docs/calibration.md) | Physical SPL, digital full-scale, RMS vs peak |
| [Block Processing](https://github.com/jmrplens/phonometry/blob/main/docs/block-processing.md) | Stateful streaming workflows |
| [Multichannel](https://github.com/jmrplens/phonometry/blob/main/docs/multichannel.md) | Vectorized multichannel analysis, performance |
| [API Reference](https://github.com/jmrplens/phonometry/blob/main/docs/api-reference.md) | Every public function and class |
| [Theory](https://github.com/jmrplens/phonometry/blob/main/docs/theory.md) | Standards, math, design decisions |
| [Why phonometry](https://github.com/jmrplens/phonometry/blob/main/docs/why-phonometry.md) | IEC compliance verification vs other libraries |
| [Conformance report](https://github.com/jmrplens/phonometry/blob/main/docs/CONFORMANCE.md) | Live per-standard numerical validation (expected vs computed) regenerated by `make conformance` |
## ⚡ Quick start
```python
import numpy as np
from phonometry import octavefilter
fs = 48000
t = np.linspace(0, 1, fs, endpoint=False)
# Composite signal: 100Hz + 1000Hz
signal = np.sin(2 * np.pi * 100 * t) + np.sin(2 * np.pi * 1000 * t)
# Apply 1/3 octave filter bank
spl, freq = octavefilter(signal, fs=fs, fraction=3)
print(f"Bands: {freq}")
print(f"SPL [dB]: {spl}")
```
*1/3 Octave Band spectrum analysis of a complex signal. More examples in the
[documentation](https://jmrplens.github.io/phonometry/).*
## 🧪 Development
```bash
make install # dependencies + editable install
make check # ruff + mypy + bandit + tests
make graphs # regenerate documentation images
```
See https://github.com/jmrplens/phonometry/blob/main/CONTRIBUTING.md and the
https://github.com/jmrplens/phonometry/blob/main/CHANGELOG.md
## 📄 License
[MIT](https://github.com/jmrplens/phonometry/blob/main/LICENSE)