123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808# Copyright (c) 2026. Jose Manuel Requena Plens"""Speech intelligibility: the SII of ANSI S3.5 and the STI of IEC 60268-16.
Two ways of asking the same question - how much of the speech survives theroom and the noise. ANSI S3.5-1997 answers it band by band, so its fourprocedures (critical band, equally contributing critical band, one-thirdoctave, octave) each need their band importance function, their workedexample from the working group and the exact index the example returns;IEC 60268-16 answers it through the modulation transfer function, so itsAnnex M example is a full 7x14 MTF matrix with the MTI and STI it yields."""
from __future__ import annotations
# ---------------------------------------------------------------------------# ANSI S3.5-1997 Speech Intelligibility Index (one-third-octave method).# Primary oracle: the reference implementation of ASA Working Group S3-79# (the committee that maintains ANSI S3.5), published on its support site# sii.to as SII.C together with official test-input files (*.TST) and their# published results (DevelopmentKit readme, three decimals). "SII.C run"# below is the value printed by that C program, compiled unmodified with gcc# and run on the stated input: committee code, independent of this library.# Secondary cross-checks retained where they agree: the Hornsby SII# worksheet (ANSIS3_51997SII.xlsx) and the R CRAN package "SII", both# independent implementations.# ---------------------------------------------------------------------------ANSIS3_5_BAND_IMPORTANCE_SUM = ( 1.0 # Table 3, sum of Ii (identical digits in SII.C i_avg[]))# Equivalent masking spectrum level Zi at 200 Hz, standard normal-effort# spectrum in quiet: SII.C run prints z[1] = -1.664717 (the Hornsby# worksheet agrees).ANSIS3_5_MASKING_Z_200HZ = -1.665# SII for the standard normal-effort spectrum in quiet (-80 dB noise) with# normal hearing: SII.C run = 0.9958251667; the Hornsby SII worksheet gives# the same digits at full precision (its column M is the clause 5.6 maximum# Di = max(Zi, Xi'); an energy sum instead reads 5e-6 low here but up to# 0.042 low in noise-plus-hearing-loss conditions).ANSIS3_5_STANDARD_QUIET = 0.99582516666667# Equivalent disturbance spectrum level Di at 5000 Hz for the same condition:# the quiet field leaves Di = Xi' = -23.6 dB (Table 3 reference internal# noise, also SII.C x[15]), which the clause 5.6 maximum preserves exactly.ANSIS3_5_DISTURBANCE_5000HZ = -23.6# Discriminating adverse-condition oracle (would catch an energy-sum Di):# normal speech, flat 30 dB noise spectrum, flat 40 dB hearing loss.# SII.C run = 0.2184539329; the Hornsby worksheet rounds it to 0.2185 (the# energy-sum variant reads 0.1841).ANSIS3_5_NOISE_PLUS_LOSS = 0.2184539329# ANSI S3.5-1997 Annex C.2 worked example (one-third-octave method): speech# 54 dB in all bands, noise 40/30/20 dB in the first three bands, normal# hearing. SII.C run = 0.8513748619; the R CRAN package "SII" prints# 0.8513749 for the same input (its vignette reproduces the standard's# Table C.2). Table C.2 carries an official WG S3-79 erratum in its first# row (self-masking slope Ci printed -45.59, corrected -46.59, sii.to# errata list); the corrected chain is what both implementations compute# (C1 = -46.587) and the printed Zi column below is only consistent with it.ANSIS3_5_ANNEX_C2 = 0.8513748619# Table C.2, printed equivalent masking spectrum level Zi of the first three# rows (two decimals, errata-consistent): the misprinted slope would give# 34.76 dB at 200 Hz instead of the printed 34.66 dB. The 250 Hz cell is# printed 25.04 while the exact chain gives 25.0468 (SII.C z[2] agrees), so# that print truncates rather than rounds; tests use a 0.01 dB tolerance.ANSIS3_5_ANNEX_C2_MASKING = (40.00, 34.66, 25.04)# Table 3, loud-effort standard speech spectrum at 1 kHz. Surrogate-anchored# (R CRAN "SII" and Google implementation transcriptions of Table 3): the WG# kit's SII.C carries only the normal-effort spectrum.ANSIS3_5_LOUD_1KHZ = 42.16# Official WG S3-79 test cases for the one-third-octave procedure# (DevelopmentKit SOURCES/TO.TST and TO_1.TST): lines are the equivalent# speech spectrum level, equivalent noise spectrum level and equivalent# hearing threshold level over the 18 bands; TO_1 adds an alternative# band-importance function (18 values consumed; the file's spurious 19th# entry is ignored by SII.C). Published results (readme, 3 decimals):# TO.TST -> 0.445, TO_1.TST -> 0.438; SII.C run at full precision:# 0.4453910059 and 0.4382176540.ANSIS3_5_WG_TO_SPEECH = ( 90.0, 5.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, -10.0, -10.0, -10.0, -10.0,)ANSIS3_5_WG_TO_NOISE = ( 10.0, -10.0, -10.0, 75.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, 10.0, 10.0, 10.0, 10.0,)ANSIS3_5_WG_TO_THRESHOLD = ( 90.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0,)ANSIS3_5_WG_TO_SII = 0.445 # published in the WG DevelopmentKit readmeANSIS3_5_WG_TO_SII_EXACT = 0.4453910059 # SII.C run on TO.TSTANSIS3_5_WG_TO1_IMPORTANCE = ( 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.3, 0.0,)ANSIS3_5_WG_TO1_SII = 0.438 # published in the WG DevelopmentKit readmeANSIS3_5_WG_TO1_SII_EXACT = 0.4382176540 # SII.C run on TO_1.TST
# Official WG S3-79 test cases for the other three band procedures# (DevelopmentKit SOURCES/CB.TST, CB_1.TST, ECB.TST, ECB_1.TST, OCTAVE.TST and# OCTAVE_1.TST). Same file layout as the one-third-octave pair above: the# equivalent speech spectrum level, the equivalent noise spectrum level and# the equivalent hearing threshold level over the procedure's bands, and for# the "_1" variants a fourth line with an alternative band-importance# function. Published results (readme, 3 decimals) and the value SII.C prints# when compiled unmodified with gcc and run on the file:## CB.TST 0.273 0.2729353808 critical band, 21 bands# CB_1.TST 0.410 0.4104741231 critical band, alternative Ii# ECB.TST 0.278 0.2781386550 equally contributing, 17 bands# ECB_1.TST 0.410 0.4104741231 equally contributing, alternative Ii# OCTAVE.TST 0.491 0.4909625062 octave, 6 bands# OCTAVE_1.TST 0.323 0.3229375000 octave, alternative Ii## CB_1.TST and ECB_1.TST are NOT two independent oracles. They coincide to# every printed digit because the equally-contributing bands are critical# bands 3 to 19 and the two alternative importance functions select the same# physical bands. The two extra critical bands below 300 Hz that only the# critical-band procedure has do not perturb the weighted bands: their masker# is the input's 10 dB noise line, and its upward spread arrives at the first# weighted band at roughly 1e-19 of the local masking energy, under double# precision. (In the lowest shared band the same contribution is 5e-2 and does# matter, but that band carries zero weight in both alternative functions.)# The eight official cases therefore carry seven independent confirmations,# not eight; the pair is still worth running, because a wrong band mapping in# either procedure would break the coincidence.ANSIS3_5_WG_CB_SPEECH = ( -10.0, -10.0, -10.0, 90.0, 5.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, -10.0, -10.0, -10.0, -10.0,)ANSIS3_5_WG_CB_NOISE = ( 10.0, 10.0, 10.0, 10.0, -10.0, -10.0, 70.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, 10.0, 10.0, 10.0, 10.0,)ANSIS3_5_WG_CB_THRESHOLD = ( 0.0, 0.0, 0.0, 90.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0,)ANSIS3_5_WG_CB_SII = 0.273 # published in the WG DevelopmentKit readmeANSIS3_5_WG_CB_SII_EXACT = 0.2729353808 # SII.C run on CB.TSTANSIS3_5_WG_CB1_IMPORTANCE = ( 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.3, 0.0, 0.0, 0.0,)ANSIS3_5_WG_CB1_SII = 0.410 # published in the WG DevelopmentKit readmeANSIS3_5_WG_CB1_SII_EXACT = 0.4104741231 # SII.C run on CB_1.TSTANSIS3_5_WG_ECB_SPEECH = ( -10.0, 90.0, 5.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, 40.0, -10.0, -10.0,)ANSIS3_5_WG_ECB_NOISE = ( 10.0, 10.0, -10.0, -10.0, 70.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, -10.0, 10.0, 10.0,)ANSIS3_5_WG_ECB_THRESHOLD = ( 0.0, 90.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0,)ANSIS3_5_WG_ECB_SII = 0.278 # published in the WG DevelopmentKit readmeANSIS3_5_WG_ECB_SII_EXACT = 0.2781386550 # SII.C run on ECB.TSTANSIS3_5_WG_ECB1_IMPORTANCE = ( 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.3, 0.0,)ANSIS3_5_WG_ECB1_SII = 0.410 # published in the WG DevelopmentKit readmeANSIS3_5_WG_ECB1_SII_EXACT = 0.4104741231 # SII.C run on ECB_1.TST# The octave case is the input printed in the DevelopmentKit readme as "the# octave band procedure of the example in Section C.1", except that OCTAVE.TST# raises the 8000 Hz equivalent hearing threshold to 7.1 dB HL where Annex C.1# has 0; ANSIS3_5_ANNEX_C1_* below carries the Annex C.1 input itself.ANSIS3_5_WG_OCTAVE_SPEECH = (50.0, 40.0, 40.0, 30.0, 20.0, 0.0)ANSIS3_5_WG_OCTAVE_NOISE = (70.0, 65.0, 45.0, 25.0, 1.0, -15.0)ANSIS3_5_WG_OCTAVE_THRESHOLD = (0.0, 0.0, 0.0, 0.0, 0.0, 7.1)ANSIS3_5_WG_OCTAVE_SII = 0.491 # published in the WG DevelopmentKit readmeANSIS3_5_WG_OCTAVE_SII_EXACT = 0.4909625062 # SII.C run on OCTAVE.TSTANSIS3_5_WG_OCTAVE1_IMPORTANCE = (0.0, 0.0, 1.0, 0.0, 0.0, 0.0)ANSIS3_5_WG_OCTAVE1_SII = 0.323 # published in the WG DevelopmentKit readmeANSIS3_5_WG_OCTAVE1_SII_EXACT = 0.3229375000 # SII.C run on OCTAVE_1.TST# Sums of the tabulated band-importance functions. Tables 1 and 4 sum to one# like Table 3; Table 2 prints 0.0588 in each of its 17 bands, so it sums to# 0.9996 (1/17 = 0.058823...) rather than to exactly one.ANSIS3_5_CRITICAL_IMPORTANCE_SUM = 1.0ANSIS3_5_OCTAVE_IMPORTANCE_SUM = 1.0ANSIS3_5_EQUAL_IMPORTANCE_SUM = 0.9996# Table 4 tabulates the standard speech spectrum level Ui and the reference# internal noise spectrum level Xi at the six octave centres as the same# figures Table 3 gives at those centres: both are spectrum (per-hertz) levels,# so they do not depend on the analysis bandwidth. SII.C carries the two tables# independently and its u[]/x[] entries agree at all six. Rows: centre# frequency in hertz, Ui and Xi in dB SPL.ANSIS3_5_OCTAVE_TABLE4_SHARED = ( (250.0, 34.75, -3.9), (500.0, 34.27, -9.7), (1000.0, 25.01, -12.5), (2000.0, 17.32, -17.7), (4000.0, 9.33, -25.9), (8000.0, 1.13, -7.1),)# ANSI S3.5-1997 Annex C.1 worked example (octave-band procedure). Its input is# printed in the WG DevelopmentKit readme: equivalent speech spectrum level# 50/40/40/30/20/0 dB, equivalent noise spectrum level 70/65/45/25/1/-15 dB,# normal hearing. SII.C run on that input = 0.5039555062.ANSIS3_5_ANNEX_C1_SPEECH = (50.0, 40.0, 40.0, 30.0, 20.0, 0.0)ANSIS3_5_ANNEX_C1_NOISE = (70.0, 65.0, 45.0, 25.0, 1.0, -15.0)ANSIS3_5_ANNEX_C1 = 0.5039555062# Table C.1, row i = 5 (the 4000 Hz octave band), column Li under Step 6, with# the official WG S3-79 erratum applied: the printed 0.10 should be 1.00. The# level-distortion factor of clause 5.7 with the example's own inputs# (Ei' = 20 dB, Ui = 9.33 dB) is 1 - (20 - 9.33 - 10)/160 = 0.99581, which is# what prints as 1.00 to two decimals.ANSIS3_5_ANNEX_C1_LEVEL_DISTORTION_I5 = 1.00# ANSI S3.5-1997 Table 1 in full, 21 rows: nominal centre frequency, lower and# upper band limit, band importance Ii, normal-effort standard speech spectrum# level Ui and reference internal noise spectrum level Xi.## Provenance differs by column and is worth stating, because this table is a# *pinning* fixture rather than an independent oracle for most of its cells:# - the band limits, Ii, Ui and Xi digits are the WG S3-79 reference# implementation SII.C (its cb() limit[], i_avg[], u[] and x[] arrays);# - the nominal centre frequencies are NOT in SII.C, which works from the# geometric centre of each band's limits. They are the classical# critical-band (Bark) centres, and the R CRAN package "SII" transcribes# the same values as Table 1's fi column;# - rows 1 to 6 are independently corroborated: the CRAN vignette prints# that head verbatim and it agrees cell for cell.## The eight official .TST cases do not exercise most of these cells (a gross# corruption of, say, Xi row 11 leaves every published result unchanged,# because a 70 dB masker drowns it), so the table is asserted directly.ANSIS3_5_CRITICAL_TABLE1 = ( (150.0, 100.0, 200.0, 0.0103, 31.44, 1.5), (250.0, 200.0, 300.0, 0.0261, 34.75, -3.9), (350.0, 300.0, 400.0, 0.0419, 34.14, -7.2), (450.0, 400.0, 510.0, 0.0577, 34.58, -8.9), (570.0, 510.0, 630.0, 0.0577, 33.17, -10.3), (700.0, 630.0, 770.0, 0.0577, 30.64, -11.4), (840.0, 770.0, 920.0, 0.0577, 27.59, -12.0), (1000.0, 920.0, 1080.0, 0.0577, 25.01, -12.5), (1170.0, 1080.0, 1270.0, 0.0577, 23.52, -13.2), (1370.0, 1270.0, 1480.0, 0.0577, 22.28, -14.0), (1600.0, 1480.0, 1720.0, 0.0577, 20.15, -15.4), (1850.0, 1720.0, 2000.0, 0.0577, 18.29, -16.9), (2150.0, 2000.0, 2320.0, 0.0577, 16.37, -18.8), (2500.0, 2320.0, 2700.0, 0.0577, 13.80, -21.2), (2900.0, 2700.0, 3150.0, 0.0577, 12.21, -23.2), (3400.0, 3150.0, 3700.0, 0.0577, 11.09, -24.9), (4000.0, 3700.0, 4400.0, 0.0577, 9.33, -25.9), (4800.0, 4400.0, 5300.0, 0.0460, 5.84, -24.2), (5800.0, 5300.0, 6400.0, 0.0343, 3.47, -19.0), (7000.0, 6400.0, 7700.0, 0.0226, 1.78, -11.7), (8500.0, 7700.0, 9500.0, 0.0110, -0.14, -6.0),)# ANSI S3.5-1997 Table 3 in full, 18 rows: centre frequency in hertz, band# importance Ii, normal-effort standard speech spectrum level Ui and reference# internal noise spectrum level Xi. Unlike Tables 1 and 4 this one has an# independent digit source: the Hornsby SII worksheet (ANSIS3_51997SII.xlsx)# transcribes it directly from the standard, and SII.C's to()/u[]/x[] arrays# agree with it cell for cell. The band limits are omitted because Table 3# prints centre frequencies only; the procedure's exact 2**(-+1/6) fi limits# are computed, not tabulated.## Pinned directly for the same reason as Tables 1 and 4: the mutation campaign# showed Xi at 2500 Hz and 3150 Hz surviving a whole-decibel corruption,# because the band audibility there is clipped at 1 in every case the suite# runs, so nothing else notices.ANSIS3_5_THIRD_OCTAVE_TABLE3 = ( (160.0, 0.0083, 32.41, 0.6), (200.0, 0.0095, 34.48, -1.7), (250.0, 0.0150, 34.75, -3.9), (315.0, 0.0289, 33.98, -6.1), (400.0, 0.0440, 34.59, -8.2), (500.0, 0.0578, 34.27, -9.7), (630.0, 0.0653, 32.06, -10.8), (800.0, 0.0711, 28.30, -11.9), (1000.0, 0.0818, 25.01, -12.5), (1250.0, 0.0844, 23.00, -13.5), (1600.0, 0.0882, 20.15, -15.4), (2000.0, 0.0898, 17.32, -17.7), (2500.0, 0.0868, 13.18, -21.2), (3150.0, 0.0844, 11.55, -24.2), (4000.0, 0.0771, 9.33, -25.9), (5000.0, 0.0527, 5.31, -23.6), (6300.0, 0.0364, 2.59, -15.8), (8000.0, 0.0185, 1.13, -7.1),)# ANSI S3.5-1997 Table 4 in full, 6 rows, same column order as Table 1 above.# Same provenance: the limits, Ii, Ui and Xi are SII.C's oct() arrays; the# nominal centres are the octave centres those limits bracket.ANSIS3_5_OCTAVE_TABLE4 = ( (250.0, 177.0, 354.0, 0.0617, 34.75, -3.9), (500.0, 354.0, 707.0, 0.1671, 34.27, -9.7), (1000.0, 707.0, 1414.0, 0.2373, 25.01, -12.5), (2000.0, 1414.0, 2828.0, 0.2648, 17.32, -17.7), (4000.0, 2828.0, 5657.0, 0.2142, 9.33, -25.9), (8000.0, 5657.0, 11314.0, 0.0549, 1.13, -7.1),)# Flat-spectrum cases run through SII.C to bring every band's Ui and Xi into# the chain, which the eight official .TST cases do not do (their strong# maskers and their -10 dB bands leave many table cells inert). Per row: the# method, the flat equivalent speech spectrum level, the flat equivalent noise# spectrum level, normal hearing throughout, and the value SII.C prints.# "quiet" (0 / -80 dB): the disturbance is Xi in every band, so every Xi# cell moves the answer.# "loud" (80 / 20 dB): the clause 5.7 level-distortion factor is below# unity in every band, so every Ui cell moves the answer.# "mid" (40 / -50 dB): both mechanisms partly active.ANSIS3_5_WG_FLAT_CASES = ( ("critical-band", "quiet", 0.0, -80.0, 0.9243383333), ("critical-band", "loud", 80.0, 20.0, 0.6892747063), ("critical-band", "mid", 40.0, -50.0, 0.9342973562), ("equally-contributing", "quiet", 0.0, -80.0, 0.9398200000), ("equally-contributing", "loud", 80.0, 20.0, 0.6877689000), ("equally-contributing", "mid", 40.0, -50.0, 0.9330641250), ("one-third-octave", "quiet", 0.0, -80.0, 0.9247666667), ("one-third-octave", "loud", 80.0, 20.0, 0.6891314875), ("one-third-octave", "mid", 40.0, -50.0, 0.9339307437), ("octave", "quiet", 0.0, -80.0, 0.9134180000), ("octave", "loud", 80.0, 20.0, 0.6903270250), ("octave", "mid", 40.0, -50.0, 0.9340358250),)
# ---------------------------------------------------------------------------# Speech transmission index - IEC 60268-16 Annex M, Table M.1 "Example# calculation" (Ed.4, 2011, printed pp. 64-66): a measured STI adjusted to# simulate occupancy noise and a different speech level. The annex walks four# numbered steps and prints every intermediate, so each row below is one# printed row of that table, transcribed verbatim. The one row two steps# print differently, the reception-threshold intensity at 250 Hz, is noted# where it is defined.## step 1 the signal and background-noise octave-band levels present during# the measurement, and the MTF matrix measured with the noise,# masking and threshold in it (rows are the 14 modulation# frequencies 0,63 Hz to 12,5 Hz, columns the 7 octave bands 125 Hz# to 8 kHz);# step 2 the same correction the forward chain applies, divided out, which# leaves the transmission channel alone;# step 3 the correction of the operational speech and occupancy-noise# levels, applied;# step 4 the A.5.4 to A.5.6 processing into effective SNRs, band MTIs and# the STI.## Two scale conventions of the printed table matter when these rows are read# against a computed quantity, and both are recorded in docs/ERRATA.md. The# combined squared sound pressure I_k is tabulated in units of# IEC60268_16_ANNEX_M_INTENSITY_SCALE (a row labelled "MPa2"), while# I_am,k and I_rt,k in the same sum are tabulated unscaled; and the auditory# masking factor has no value in the 125 Hz band, which has no band below it# to be masked by, where the table prints "not applicable" and these rows# carry None.# ---------------------------------------------------------------------------#: Units the "Combined squared sound pressure I_k" row is printed in, as a#: ratio to p0^2 = (20 uPa)^2. The rows it is added to are printed unscaled.IEC60268_16_ANNEX_M_INTENSITY_SCALE = 1e6
# Step 1: acquire measurement data.IEC60268_16_ANNEX_M_MEASURED_LEVEL = (77.9, 77.9, 74.2, 68.2, 62.2, 56.2, 50.2)IEC60268_16_ANNEX_M_MEASURED_AMBIENT = (48.0, 40.0, 34.0, 30.0, 27.0, 25.0, 23.0)IEC60268_16_ANNEX_M_MEASURED_MTF = ( (0.982, 0.952, 0.960, 0.969, 0.979, 0.983, 0.994), (0.966, 0.928, 0.941, 0.954, 0.969, 0.976, 0.992), (0.945, 0.897, 0.914, 0.933, 0.955, 0.965, 0.989), (0.919, 0.862, 0.881, 0.908, 0.939, 0.952, 0.984), (0.884, 0.819, 0.836, 0.873, 0.915, 0.932, 0.978), (0.850, 0.784, 0.793, 0.838, 0.890, 0.911, 0.971), (0.815, 0.750, 0.749, 0.799, 0.862, 0.888, 0.961), (0.772, 0.715, 0.716, 0.760, 0.832, 0.863, 0.950), (0.740, 0.678, 0.691, 0.730, 0.800, 0.836, 0.938), (0.724, 0.623, 0.665, 0.721, 0.772, 0.811, 0.926), (0.713, 0.553, 0.643, 0.708, 0.745, 0.785, 0.913), (0.669, 0.515, 0.611, 0.664, 0.720, 0.764, 0.901), (0.590, 0.479, 0.545, 0.603, 0.693, 0.748, 0.890), (0.553, 0.442, 0.513, 0.602, 0.678, 0.736, 0.881),)
# Step 2: remove background noise, masking and threshold factors. The two# "adjustment" rows are reciprocals of the corresponding transfer factors,# which is how the annex writes a correction it is undoing.IEC60268_16_ANNEX_M_MEASURED_SNR = (29.90, 37.90, 40.20, 38.20, 35.20, 31.20, 27.20)IEC60268_16_ANNEX_M_MEASURED_NOISE_TRANSFER = ( 0.999, 1.000, 1.000, 1.000, 1.000, 0.999, 0.998,)IEC60268_16_ANNEX_M_MEASURED_NOISE_ADJUSTMENT = ( 1.001, 1.000, 1.000, 1.000, 1.000, 1.001, 1.002,)IEC60268_16_ANNEX_M_MEASURED_COMBINED_LEVEL = ( 77.90, 77.90, 74.20, 68.20, 62.20, 56.20, 50.21,)IEC60268_16_ANNEX_M_MEASURED_MASKING_DB = ( None, -20.8, -20.8, -22.7, -25.7, -33.9, -36.9,)IEC60268_16_ANNEX_M_MEASURED_INTENSITY = (61.7, 61.7, 26.3, 6.61, 1.66, 0.417, 0.105)IEC60268_16_ANNEX_M_MEASURED_MASKING_MILLI = ( None, 8.22, 8.22, 5.37, 2.69, 0.407, 0.204,)IEC60268_16_ANNEX_M_MEASURED_INTENSITY_MASKING = ( 0.0, 508_000.0, 507_000.0, 141_000.0, 17_800.0, 676.0, 85.2,)IEC60268_16_ANNEX_M_MEASURED_MASKING_THRESHOLD_ADJUSTMENT = ( 1.001, 1.008, 1.019, 1.021, 1.011, 1.002, 1.001,)IEC60268_16_ANNEX_M_MEASURED_COMBINED_ADJUSTMENT = ( 1.002, 1.008, 1.019, 1.022, 1.011, 1.002, 1.003,)#: Adjusted MTF matrix without noise, masking and threshold (step 2 output).IEC60268_16_ANNEX_M_SOURCE_MTF = ( (0.983, 0.960, 0.978, 0.990, 0.990, 0.986, 0.997), (0.968, 0.936, 0.959, 0.974, 0.980, 0.979, 0.995), (0.947, 0.904, 0.931, 0.953, 0.966, 0.968, 0.992), (0.920, 0.869, 0.898, 0.927, 0.949, 0.955, 0.987), (0.886, 0.826, 0.852, 0.892, 0.925, 0.935, 0.981), (0.851, 0.791, 0.808, 0.856, 0.900, 0.914, 0.974), (0.816, 0.756, 0.764, 0.816, 0.871, 0.891, 0.964), (0.773, 0.721, 0.730, 0.776, 0.841, 0.866, 0.953), (0.741, 0.684, 0.705, 0.745, 0.809, 0.838, 0.941), (0.726, 0.628, 0.678, 0.736, 0.780, 0.812, 0.929), (0.714, 0.557, 0.656, 0.723, 0.753, 0.786, 0.916), (0.670, 0.520, 0.623, 0.678, 0.728, 0.765, 0.904), (0.591, 0.483, 0.556, 0.615, 0.701, 0.749, 0.893), (0.554, 0.446, 0.523, 0.614, 0.685, 0.737, 0.884),)
#: Absolute speech reception threshold ART_k, printed once per step with the#: same values (Table A.2 of the same edition), and the intensity it becomes.#: The step 3 print of the 250 Hz cell reads 500 where step 2 reads 501; both#: are roundings of 10^2,7 = 501,19, at three and at two significant figures.IEC60268_16_ANNEX_M_ART_DB = (46.0, 27.0, 12.0, 6.5, 7.5, 8.0, 12.0)IEC60268_16_ANNEX_M_INTENSITY_THRESHOLD = ( 40_000.0, 501.0, 15.8, 4.5, 5.6, 6.3, 15.8,)
# Step 3: adjust for operational speech and occupancy-noise levels. The annex# prints these two as transfer factors, not as reciprocals, because here the# correction is being applied rather than undone.IEC60268_16_ANNEX_M_OPERATIONAL_LEVEL = (82.9, 82.9, 79.2, 73.2, 67.2, 61.2, 55.2)IEC60268_16_ANNEX_M_OPERATIONAL_AMBIENT = (55.5, 47.5, 41.5, 37.5, 34.5, 32.5, 30.5)IEC60268_16_ANNEX_M_OPERATIONAL_SNR = (27.40, 35.40, 37.70, 35.70, 32.70, 28.70, 24.70)IEC60268_16_ANNEX_M_OPERATIONAL_NOISE_TRANSFER = ( 0.998, 1.000, 1.000, 1.000, 0.999, 0.999, 0.997,)IEC60268_16_ANNEX_M_OPERATIONAL_COMBINED_LEVEL = ( 82.9, 82.9, 79.2, 73.2, 67.2, 61.2, 55.2,)IEC60268_16_ANNEX_M_OPERATIONAL_MASKING_DB = ( None, -18.3, -18.3, -20.2, -23.2, -26.2, -34.4,)IEC60268_16_ANNEX_M_OPERATIONAL_INTENSITY = ( 195.0, 195.0, 83.2, 20.9, 5.25, 1.32, 0.332,)IEC60268_16_ANNEX_M_OPERATIONAL_MASKING_MILLI = ( None, 14.6, 14.6, 9.55, 4.79, 2.40, 0.363,)#: I_am,k of step 3. The 250 Hz cell is printed 2 850 000 where the quantity#: it names is 2 858 804; see docs/ERRATA.md, "IEC 60268-16:2011, Table M.1,#: step 3 I_am,k at 250 Hz".IEC60268_16_ANNEX_M_OPERATIONAL_INTENSITY_MASKING = ( 0.0, 2_850_000.0, 2_850_000.0, 795_000.0, 100_000.0, 12_600.0, 480.0,)IEC60268_16_ANNEX_M_OPERATIONAL_MASKING_THRESHOLD_TRANSFER = ( 1.000, 0.986, 0.967, 0.963, 0.981, 0.991, 0.999,)IEC60268_16_ANNEX_M_OPERATIONAL_COMBINED_ADJUSTMENT = ( 0.998, 0.985, 0.967, 0.963, 0.981, 0.989, 0.995,)#: Adjusted MTF matrix for operational levels, masking and threshold.IEC60268_16_ANNEX_M_OPERATIONAL_MTF = ( (0.981, 0.946, 0.946, 0.953, 0.971, 0.975, 0.992), (0.966, 0.922, 0.927, 0.938, 0.961, 0.968, 0.990), (0.945, 0.891, 0.900, 0.918, 0.947, 0.957, 0.987), (0.919, 0.856, 0.868, 0.893, 0.931, 0.944, 0.982), (0.884, 0.814, 0.823, 0.859, 0.907, 0.925, 0.976), (0.850, 0.779, 0.781, 0.824, 0.882, 0.904, 0.969), (0.814, 0.745, 0.738, 0.786, 0.855, 0.881, 0.959), (0.772, 0.710, 0.706, 0.747, 0.825, 0.856, 0.948), (0.739, 0.674, 0.681, 0.718, 0.793, 0.829, 0.936), (0.724, 0.619, 0.656, 0.709, 0.765, 0.804, 0.924), (0.713, 0.549, 0.634, 0.696, 0.739, 0.778, 0.911), (0.668, 0.512, 0.602, 0.653, 0.714, 0.757, 0.900), (0.589, 0.476, 0.537, 0.593, 0.687, 0.741, 0.889), (0.553, 0.439, 0.505, 0.592, 0.672, 0.729, 0.880),)
# Step 4: process the MTF matrix to yield the STI (4a effective SNRs, 4b the# +/-15 dB clamp, 4c the transmission indices and the band MTIs). The printed# 4b and 4c matrices are deliberately not transcribed: the annex derives them# by rounding the 4a print and clamping it, a display chain, while clauses# A.5.4 to A.5.5 define them from the unrounded SNRs, so they are not oracles# for a library that never rounds mid-chain. The 4a matrix, the band MTIs and# the STI below are what the computation is checked against.IEC60268_16_ANNEX_M_EFFECTIVE_SNR = ( (17.21, 12.44, 12.42, 13.09, 15.21, 15.93, 21.01), (14.55, 10.73, 11.04, 11.83, 13.90, 14.83, 20.02), (12.34, 9.13, 9.56, 10.47, 12.52, 13.50, 18.86), (10.52, 7.74, 8.17, 9.22, 11.31, 12.30, 17.41), (8.82, 6.41, 6.69, 7.84, 9.91, 10.88, 16.13), (7.52, 5.47, 5.52, 6.71, 8.76, 9.73, 14.98), (6.42, 4.66, 4.51, 5.64, 7.70, 8.69, 13.72), (5.29, 3.89, 3.80, 4.71, 6.73, 7.75, 12.64), (4.53, 3.16, 3.30, 4.06, 5.84, 6.87, 11.68), (4.19, 2.11, 2.79, 3.87, 5.14, 6.12, 10.87), (3.95, 0.85, 2.38, 3.60, 4.51, 5.44, 10.13), (3.04, 0.21, 1.80, 2.74, 3.97, 4.94, 9.52), (1.57, -0.42, 0.65, 1.63, 3.42, 4.57, 9.02), (0.92, -1.06, 0.10, 1.61, 3.12, 4.31, 8.64),)IEC60268_16_ANNEX_M_MTI = (0.73, 0.66, 0.67, 0.71, 0.77, 0.80, 0.92)IEC60268_16_ANNEX_M_STI = 0.76