[READ-ONLY] Mirror of https://github.com/jmrplens/phonometry. Standards-conformant acoustics library for Python: measurement and metrology, docs.jmrp.io/phonometry
phonometry docs api-reference.md

← Documentation index

API Reference #

All core functionality can be imported directly from the phonometry package.

Name Type Description (Inputs) Usage Snippet (Outputs)
octavefilter function High-level analysis.
• x: Signal array
• fs: Sample rate [Hz]
• fraction: 1, 3, etc. (Default: 1)
• order: Filter order (Default: 6)
• limits: [f_min, f_max] (Default: [12, 20000])
• filter_type: 'butter', 'cheby1', 'cheby2', 'ellip', 'bessel' (Default: 'butter')
• sigbands: Return time signals (Default: False)
• detrend: Remove DC offset (Default: True)
• calibration_factor: Sensitivity multiplier (Default: 1.0)
• dbfs: Output in dBFS instead of dB SPL (Default: False)
• mode: 'rms' or 'peak' (Default: 'rms')
• nominal: IEC 61260-1 nominal labels (Default: False)
• show: Plot response (Default: False)
• plot_file: Path to save plot (Default: None)
• ripple: Passband ripple [dB] (for cheby1/ellip)
• attenuation: Stopband atten. [dB] (Default: 72; for cheby2/ellip — cheby2 needs >= 70 dB for class 1)
spl, freq = octavefilter(x, fs, ...)
• spl: levels [dB]
• freq: frequencies [Hz]

With sigbands=True:
spl, freq, xb = octavefilter(x, fs, sigbands=True)
• xb: List of filtered signals (one per band)

Calibrated usage:
spl, f = octavefilter(x, fs, calibration_factor=0.05)
OctaveFilterBank class Efficient bank implementation.
• fs: Sample rate [Hz]
• fraction: 1, 3, etc.
• order: Filter order
• limits: [f_min, f_max] (Default: [12, 20000])
• filter_type: Architecture name
• show: Plot response (Default: False)
• plot_file: Path to save the plot (Default: None)
• calibration_factor: Sensitivity multiplier
• dbfs: Use dBFS (Default: False)
• stateful: Carry filter state between calls (Default: False)
• steady_ic: Steady-state initial conditions (Default: False)
• resample: Multirate decimation (Default: True)
• ripple: Passband ripple [dB]
• attenuation: Stopband attenuation [dB] (Default: 72; cheby2 needs >= 70 dB for class 1)
bank = OctaveFilterBank(fs=48000, fraction=3, order=6, filter_type='butter')
spl, f = bank.filter(x, sigbands=False, mode='rms', detrend=True, zero_phase=False)

• bank: Instance of the filter bank
• bank.freq / bank.freq_d / bank.freq_u / bank.sos: computed properties
OctaveFilterBank.spectrogram method Band levels over time.
• x: Signal array (1D or 2D)
• window_time: Window length [s] (Default: 0.125)
• overlap: Fraction in [0, 1) (Default: 0.5)
• mode: 'rms' or 'peak'
• zero_phase: Group-delay-free frames (Default: False)
levels, freq, times = bank.spectrogram(x)

• levels: (bands, frames) or (channels, bands, frames)
• times: window centers [s]
weighting_filter function Acoustic weighting.
• x: Signal array
• fs: Sample rate [Hz]
• curve: 'A', 'C', 'G' (ISO 7196 infrasound) or 'Z' (Default: 'A')
• high_accuracy: IEC class 1 HF accuracy via internal oversampling (Default: True)
y = weighting_filter(x, fs, curve='A')

• y: weighted signal
WeightingFilter class Reusable weighting filter.
• fs: Sample rate [Hz]
• curve: 'A', 'C', 'G' or 'Z'
• stateful: Block processing (Default: False)
• steady_ic: Steady-state initial conditions (Default: False)
• high_accuracy: Defaults to True except stateful
wf = WeightingFilter(fs, 'A')
y = wf.filter(x)
time_weighting function Energy capture.
• x: Raw signal array (squared internally; time is the last axis)
• fs: Sample rate [Hz]
• mode: 'fast', 'slow', or 'impulse'
• initial_state: None, 'zero', 'first', scalar, or array (Default: None)
env = time_weighting(x, fs, mode='fast')

• env: energy envelope (Mean Square), same shape as x
TimeWeighting class Stateful time weighting.
• fs: Sample rate [Hz]
• mode: 'fast', 'slow', 'impulse' (Default: 'fast')
tw = TimeWeighting(fs, mode='fast')
env = tw.process(block) per block
tw.reset() to start over
leq function Equivalent level (Leq).
• x: Signal array (1D or 2D)
• calibration_factor: Sensitivity multiplier (Default: 1.0)
• dbfs: Output in dBFS (Default: False)
level = leq(x, calibration_factor=s)

• level: Scalar (1D) or per-channel array (2D)
laeq function A-weighted Leq (LAeq).
• x: Signal array (1D or 2D)
• fs: Sample rate [Hz]
• calibration_factor / dbfs: as leq
level = laeq(x, fs, calibration_factor=s)

• level: Scalar (1D) or per-channel array (2D)
ln_levels function Statistical levels (LN).
• x: Signal array (1D or 2D)
• fs: Sample rate [Hz]
• n: Exceedance percentiles (Default: (10, 50, 90))
• mode: 'fast', 'slow', 'impulse' (Default: 'fast')
• weighting: 'A', 'C', 'G', 'Z' or None (Default: None)
• calibration_factor / dbfs: as leq
stats = ln_levels(x, fs, n=(10, 50, 90), weighting='A')

• stats: Dict {10: L10, 50: L50, 90: L90}
lc_peak function C-weighted peak (LCpeak).
• x: Signal array (1D or 2D)
• fs: Sample rate [Hz]
• calibration_factor: as leq
• dbfs: 0 dBFS = full-scale peak (amplitude 1.0), unlike the RMS reference of leq
• oversample: HF inter-sample peak recovery (Default: 8; 1 = on-grid, under-reads up to ~1.15 dB at 48 kHz)
peak = lc_peak(x, fs)

• IEC 61672-1 §5.13; verified against Table 5
sel function Sound exposure level (SEL/LAE).
• x: Whole-event signal (1D or 2D)
• fs: Sample rate [Hz]
• weighting: 'A', 'C', 'G', 'Z' or None (Default: None)
• calibration_factor / dbfs: as leq
lae = sel(x, fs, weighting='A')

• Event level normalized to 1 s
sound_exposure function A-weighted exposure E (IEC 61252).
• x: Signal (1D or 2D)
• fs: Sample rate [Hz]
• duration_hours: exposure period represented (Default: recording length)
• calibration_factor
E = sound_exposure(x, fs, duration_hours=8)

• E: Pa²·h
lex_8h function Daily exposure LEX,8h / LEP,d.
• Same params as sound_exposure
lex = lex_8h(x, fs, duration_hours=4)

• Normalized 8 h level [dB]
loudness_zwicker function Zwicker loudness (ISO 532-1:2017).
• x: Calibrated signal in Pa (1D)
• fs: Sample rate [Hz]
• field: 'free' or 'diffuse' (Default: 'free')
• stationary: Clause 5 stationary method (Default: False)
• calibration_factor: Digital units to Pa (Default: 1.0)
res = loudness_zwicker(x, fs)

• ZwickerLoudness; time-varying runs add N5/N10 and the 500 Hz N(t) trace
loudness_zwicker_from_spectrum function Stationary loudness from band levels.
• levels: 28 one-third-octave levels, 25 Hz-12.5 kHz [dB SPL]
• field: 'free' or 'diffuse' (Default: 'free')
res = loudness_zwicker_from_spectrum(levels)

• res.loudness [sone], res.loudness_level [phon]
ZwickerLoudness dataclass Loudness result.
• loudness: N [sone]
• loudness_level: LN [phon]
• specific: N′(z), 240 bins of 0.1 Bark
• n5 / n10: percentile loudness (time-varying only)
• time / loudness_vs_time: 500 Hz trace
res.loudness, res.n5

• Time-varying fields are None for stationary results
sharpness_din function Sharpness in acum (DIN 45692).
• x: Signal (1D)
• fs: Sample rate [Hz]
• field: 'free' or 'diffuse' (Default: 'free')
• method: 'din', 'aures' or 'bismarck' (Default: 'din')
• calibration_factor: Digital units to Pa (Default: 1.0)
s = sharpness_din(x, fs)

• s: sharpness [acum]
sharpness_din_from_specific function Sharpness from a specific-loudness pattern.
• specific: N′(z), 240 values at 0.1 Bark (e.g. ZwickerLoudness.specific)
• method: 'din', 'aures' or 'bismarck' (Default: 'din')
s = sharpness_din_from_specific(res.specific)

• s: sharpness [acum]
equal_loudness_contour function ISO 226:2023 equal-loudness contour.
• phon: Loudness level, 20-90 phon
freqs, spl = equal_loudness_contour(40.0)

• SPL at the 29 preferred frequencies
loudness_level function Loudness level of a pure tone (phon).
• spl: Tone SPL [dB]
• frequency: One of the 29 Table 1 frequencies [Hz]
phon = loudness_level(73.0, 63.0)
hearing_threshold function Threshold of hearing (ISO 226 Table 1).
• (no parameters)
freqs, tf = hearing_threshold()
tone_to_noise_ratio function Tone-to-noise ratio (ECMA-418-1 §11).
• x: Signal (1D)
• fs: Sample rate [Hz]
• tone_freq: Tone to assess [Hz] (Default: highest peak)
• resolution_hz: FFT bin spacing (Default: 1.0)
r = tone_to_noise_ratio(x, fs)

• ToneAssessment(frequency, ratio_db, criterion_db, prominent)
prominence_ratio function Prominence ratio (ECMA-418-1 §12).
• Same params as tone_to_noise_ratio
r = prominence_ratio(x, fs, tone_freq=1000)

• ToneAssessment(...)
ToneAssessment dataclass Tone prominence verdict.
• frequency: Assessed tone [Hz]
• ratio_db: TNR or PR [dB]
• criterion_db: Prominence limit at that frequency [dB]
• prominent: bool
r = tone_to_noise_ratio(x, fs)
if r.prominent: ...
sti_from_impulse_response function Full STI, indirect method (IEC 60268-16 Ed. 5).
• ir: Impulse response (1D)
• fs: Sample rate [Hz] (>= 22500)
• snr: SNR [dB], scalar or 7 bands (Default: None)
• level: 7 speech band levels [dB SPL]; enables masking + reception threshold (Default: None)
• ambient: 7 noise band levels [dB SPL]; requires level
res = sti_from_impulse_response(ir, fs, snr=25.0)

• STIResult with mtf (7×14)
stipa function STIPA direct method (Annex B).
• x: Recorded STIPA signal (1D), 15-25 s
• fs: Sample rate [Hz] (>= 22500)
• reference: Measured source signal instead of the nominal m = 0.55 (Default: None)
• level / ambient: as sti_from_impulse_response
• warns (UserWarning) if the recording is < 15 s (STI biased low)
res = stipa(recording, fs)

• STIResult with mtf (7×2)
stipa_signal function STIPA test-signal generator (A.4/A.6.1).
• fs: Sample rate [Hz] (>= 22500)
• seconds: Duration [s] (Default: 18.0)
• level_db: RMS level [dB SPL] (Default: None → RMS 0.1)
• seed: Pink-noise seed (Default: None)
sig = stipa_signal(48000, seconds=18.0)

• 1D test signal, Ed. 5 male spectrum
STIResult dataclass STI result.
• sti: 0 to 1
• mti: band indices (7,)
• mtf: corrected m values (7×14 or 7×2)
• band_levels: levels used or None
• rating: Annex F letter 'A+'…'U'
res = stipa(x, fs)
print(res.sti, res.rating)
sound_intensity function p-p sound intensity (IEC 61043).
• p1, p2: Microphone signals [Pa], equal length
• fs: Sample rate [Hz]
• spacing: Microphone separation Δr [m]
• rho: Air density (Default: 1.204)
• c: Speed of sound (Default: 343.0)
• fraction: None, 1 or 3 (Default: None)
• limits: [f_min, f_max] (Default: [12, 20000])
• bias_correct: undo finite-difference under-read of band/broadband totals near max_valid_frequency (Default: False)
res = sound_intensity(p1, p2, fs, spacing=0.012, fraction=3)

• IntensityResult
IntensityResult dataclass Intensity result.
• Per band (with fraction): frequency, intensity [W/m²], intensity_level, pressure_level, pressure_intensity_index, direction (±1), bias_correction
• Broadband: total_* counterparts
• max_valid_frequency: 0.1·c/Δr
res.total_intensity_level
res.total_direction
field_indicators function ISO 9614-1 Annex A field indicators.
• pressure_levels: Lpi per position [dB]
• normal_intensity: Signed Ini per position [W/m²]
fi = field_indicators(lp, i_n)

• FieldIndicators(f2, f3, f4)
dynamic_capability_index function Dynamic capability Ld (ISO 9614-1 §3.12).
• pressure_residual_intensity_index: δpI0 [dB]
• bias_error_factor: K [dB] (Default: 10.0)
ld = dynamic_capability_index(18.0)

• Adequate when Ld > F2 (criterion 1)
CalibrationWarning warning class Unreliable calibration recording.
Emitted by calculate_sensitivity — with fs given and validate=True — when the tone is unstable (IEC 60942 limit) or too short
warnings.simplefilter("error", CalibrationWarning)
lden function Day-evening-night level (ISO 1996-1 §3.6.4).
• lday/levening/lnight: LAeq per period [dB]
• hours: Period durations (Default: (12, 4, 8))
l = lden(63.2, 58.1, 51.4)
ldn function Day-night level (ISO 1996-1 §3.6.5).
• lday/lnight: LAeq per period [dB]
• hours: Default (15, 9)
l = ldn(63.2, 51.4)
composite_rating_level function Whole-day composite rating (ISO 1996-1 §6.5).
• periods: list of (level_db, hours, adjustment_db) summing 24 h
r = composite_rating_level([(63, 12, 0), (58, 4, 5), (51, 8, 10)])
linkwitz_riley function Audio crossover.
• x: Signal array
• fs: Sample rate [Hz]
• freq: Crossover frequency [Hz]
• order: Any even number (Default: 4)
lo, hi = linkwitz_riley(x, fs, freq=1000, order=4)

• lo: Low-pass filtered signal
• hi: High-pass filtered signal
calculate_sensitivity function SPL Calibration.
• ref_signal: Calibration signal
• target_spl: Level of calibrator (Default: 94.0)
• ref_pressure: Reference pressure (Default: 20e-6)
• narrowband: coherent Goertzel tone estimate that rejects broadband hum/noise (needs fs; Default: False)
s = calculate_sensitivity(ref_signal, target_spl=94.0)

• s: Float (multiplier for pressure)
verify_filter_class function IEC 61260-1:2014 class check.
• bank: an OctaveFilterBank
• num_points: frequency grid points per band (Default: 32768)
result = verify_filter_class(bank)

• result["overall_class"]: 1, 2 or None
• result["bands"]: per-band class and margins [dB]
getansifrequencies function ANSI Frequency generator.
• fraction: 1, 3, etc. (Required)
• limits: [f_min, f_max] (Default: [12, 20000])
f_cen, f_low, f_high, labels = getansifrequencies(fraction=3)

• f_cen: List of center frequencies [Hz]
• f_low: List of lower edges [Hz]
• f_high: List of upper edges [Hz]
• labels: IEC nominal frequency labels
normalizedfreq function Standard IEC Frequencies.
• fraction: 1 or 3
freqs = normalizedfreq(fraction=3)

• freqs: List of standard center frequencies [Hz]
sweep_signal function ESS excitation (ISO 18233 Annex B).
• fs: Sample rate [Hz]
• f1: Start frequency [Hz]
• f2: Stop frequency [Hz] (≤ fs/2)
• seconds: Duration [s]
• amplitude: Peak (Default: 1.0)
• fade: Half-Hann fraction (Default: 0.01)
s = sweep_signal(48000, 20, 20000, 3.0)

• 1D exponential sine sweep
inverse_filter function Farina inverse filter for an ESS.
• Same parameters as sweep_signal
inv = inverse_filter(48000, 20, 20000, 3.0)

• Time-reversed, +6 dB/oct compensated sweep
impulse_response function Sweep deconvolution (ISO 18233 B.5).
• recorded: Recorded response (1D)
• reference: Emitted sweep (1D)
• fs: Sample rate [Hz]
• method: 'spectral' (Default) or 'farina'
• f_range: (f1, f2) for 'farina'
• regularization: Tikhonov term (Default: 1e-6)
• length: causal samples (Default: len(recorded))
• return_full: keep distortion tail (Default: False)
ir = impulse_response(rec, sweep, fs)

• 1D impulse response
mls_signal function Maximum-length sequence (ISO 18233 Annex A).
• order: Register length N, 2-20
mls = mls_signal(16)

• Bipolar sequence, length 2**N − 1
mls_impulse_response function IR from a periodic MLS.
• recorded: Response spanning whole MLS periods (1D)
• mls: Excitation sequence
• length: IR samples (Default: 2**N − 1)
ir = mls_impulse_response(rec, mls)

• Circular cross-correlation / averaging
decay_curve function Schroeder decay curve (ISO 3382-1 5.3.3).
• ir: Impulse response (1D)
• fs: Sample rate [Hz]
• band: Band centre [Hz] (Default: None → broadband)
• fraction: 1 or 3 (Default: 1)
• zero_phase: forward-backward band filtering, halves the 125 Hz short-T bias (Default: False)
dc = decay_curve(ir, fs) → DecayCurve
time, level = dc still unpacks (time [s], level [dB], 0 dB at t=0)
dc.plot() draws the decay + EDT/T20/T30 fits
room_parameters function Room acoustics (ISO 3382-1/2).
• ir: Impulse response (1D)
• fs: Sample rate [Hz]
• limits: (f_min, f_max) or None (Default: (125, 4000))
• fraction: 1 or 3 (Default: 1)
• zero_phase: forward-backward octave filtering, halves the 125 Hz short-T T30 bias (Default: False)
res = room_parameters(ir, fs)

• RoomAcousticsResult per band
RoomAcousticsResult dataclass Per-band room parameters.
• frequency [Hz]
• edt, t20, t30 [s]
• c50, c80 [dB], d50, ts [s]
• dynamic_range [dB]
• edt_valid/t20_valid/t30_valid
• curvature [%]
res.t30, res.c80, res.t30_valid

• Arrays with one entry per band
open_plan_metrics function Open-plan office metrics (ISO 3382-3).
• positions_m: Source distances [m] (≥ 4)
• spl_a_speech: A-weighted speech level per position [dB]
• sti_values: STI per position
m = open_plan_metrics(r, lp, sti)

• OpenPlanResult
OpenPlanResult dataclass Open-plan single numbers.
• d2s: Spatial decay rate [dB/doubling]
• lp_as_4m: Speech level at 4 m [dB]
• rd: Distraction distance [m]
• rp: Privacy distance [m]
m.d2s, m.rd, m.rp

• nan when undefined
airborne_insulation function Field airborne insulation (ISO 16283-1).
• l1/l2: Source/receiving levels [dB], 1D or (positions, bands)
• t2: Receiving-room T per band [s]
• area: Partition S [m²] (for R')
• volume: Receiving V [m³] (for R')
• t0: Reference T0 [s] (Default: 0.5)
ins = airborne_insulation(l1, l2, t2, area=10, volume=50)

• AirborneInsulationResult
weighted_rating function Single-number rating + C/Ctr (ISO 717-1).
• values_by_band: 16 thirds or 5 octaves [dB]
• bands: 'third-octave', 'octave' or None
w = weighted_rating(R)

• WeightedRatingResult (Rw, C, Ctr)
energy_average_level function Energy-average level (ISO 16283-1 (9)).
• levels: Levels [dB] to average
• axis: Averaging axis (Default: -1)
L = energy_average_level([60, 66])

• 10 lg( mean(10^(Li/10)) )
AirborneInsulationResult dataclass Field insulation per band.
• d: Level difference D [dB]
• dnt: Standardized DnT [dB]
• r_prime: Apparent R' [dB] or None
res.d, res.dnt, res.r_prime
WeightedRatingResult dataclass Weighted rating result.
• rating: Rw/DnT,w … [dB], int
• c: Spectrum term C, int
• ctr: Spectrum term Ctr, int
• unfavourable_sum: [dB]
• band_centers: Measured-curve centres [Hz] or None
• measured: Measured band values [dB] or None
• shifted_reference: Shifted Table 3 reference [dB] or None
w.rating, w.c, w.ctr
impact_insulation function Field impact insulation (ISO 16283-2).
• li: Impact SPL [dB], 1D or (positions, bands)
• t2: Receiving-room T per band [s]
• volume: Receiving V [m³] (for L'n)
• t0: Reference T0 [s] (Default: 0.5)
imp = impact_insulation(li, t2, volume=50)

• ImpactInsulationResult (l_n_t, l_n)
weighted_impact_rating function Single-number impact rating + CI (ISO 717-2).
• values_by_band: 16 thirds (100-3150 Hz) or 5 octaves (125-2000 Hz) [dB]
• bands: 'third-octave', 'octave' or None
r = weighted_impact_rating(imp.l_n_t)

• ImpactRatingResult (Ln,w, CI); octave rating carries the -5 dB rule
ImpactInsulationResult dataclass Impact insulation per band.
• l_n_t: Standardized L'nT [dB]
• l_n: Normalized L'n [dB] or None
imp.l_n_t, imp.l_n
ImpactRatingResult dataclass Weighted impact rating.
• rating: Ln,w/L'n,w/L'nT,w [dB], int
• ci: Spectrum term CI, int
• unfavourable_sum: [dB]
• band_centers: Measured-curve centres [Hz] or None
• measured: Measured impact levels [dB] or None
• shifted_reference: Shifted impact reference [dB] or None
r.rating, r.ci
sound_power_pressure function Sound power from surface pressure (ISO 3744/3746).
• levels_positions: (NM, NB) SPL [dB]
• surface: 'hemisphere' / 'box'
• radius [m] or dimensions+distance [m]
• reflecting_planes: 1/2/3 (Default: 1)
• background_levels: for K1
• frequencies [Hz]: for LWA
• reverberation_time+room_volume / absorption_area / mean_absorption_coefficient+room_surface: for K2
• grade: 'engineering' (Default) / 'survey'
• omc_uncertainty [dB] (Default: 0)
res = sound_power_pressure(levels, 'hemisphere', radius=1.5, frequencies=f)

• SoundPowerResult
measurement_positions function Hemisphere mic coordinates (ISO 3744 Annex B).
• surface: 'hemisphere'
• radius [m]
• reflecting_planes: 1/2/3
• tones: Table B.1 vs B.2 (Default: True)
• grade: 'engineering'/'survey'
xyz = measurement_positions('hemisphere', radius=1.5)

• (N, 3) coordinates [m]
background_noise_correction function Background correction K1 (ISO 3744 Eq. 16).
• source_levels [dB]
• background_levels [dB]
• grade: 'engineering'/'survey'
k1 = background_noise_correction(src, bg)

• K1 per band [dB]
environmental_correction function Environmental correction K2 (ISO 3744 Eq. A.2).
• surface_area S [m²]
• absorption_area A, or reverberation_time+room_volume, or mean_absorption_coefficient+room_surface
k2 = environmental_correction(14.1, reverberation_time=0.6, room_volume=300)

• K2 [dB]
SoundPowerResult dataclass Surface-pressure sound power.
• sound_power_level [dB]
• surface_pressure_level, mean_pressure_level [dB]
• background_correction, environmental_correction [dB]
• directivity_index [dB] (NM, NB)
• surface_area [m²]
• sound_power_level_a [dB]
• uncertainty [dB]
• grade
res.sound_power_level, res.sound_power_level_a
sound_power_reverberation function Reverberation-room LW, direct (ISO 3741).
• levels: mean room SPL [dB] (1D or (NM, NB))
• t60 [s]
• volume V [m³]
• surface_area S [m²]
• frequencies [Hz] (required)
• background_levels: for K1
• temperature [°C] (Default: 23)
• static_pressure [kPa] (Default: 101.325)
rev = sound_power_reverberation(lp, t60, 200, 220, f)

• ReverberationSoundPowerResult
sound_power_comparison function Reverberation-room LW, comparison (ISO 3741).
• levels, levels_ref: room SPL [dB]
• lw_ref: reference-source LW [dB]
• frequencies [Hz]
• background_levels, background_levels_ref
• temperature, static_pressure
cmp = sound_power_comparison(lp, lp_ref, lw_ref)

• ReverberationSoundPowerResult (method='comparison')
ReverberationSoundPowerResult dataclass Reverberation-room sound power.
• frequencies [Hz] (or None)
• sound_power_level [dB]
• mean_pressure_level [dB]
• absorption_area [m²]
• waterhouse_correction [dB]
• background_correction, c1, c2 [dB]
• speed_of_sound [m/s]
• sound_power_level_a [dB]
• method
rev.sound_power_level, rev.waterhouse_correction
sound_power_intensity function Sound power by intensity scanning (ISO 9614-2).
• normal_intensity: (N_seg, N_bands) [W/m²]
• areas: segment Si [m²]
• normal_intensity_2: 2nd sweep (criterion 3)
• pressure_levels: for FpI
• pressure_residual_index: δpI0 [dB]
• frequencies [Hz]
• band_type: 'third' (Default)/'octave'
• grade: 'engineering'/'survey'
• repeatability_limit: override s
ir = sound_power_intensity(scan1, areas, frequencies=f, band_type='octave')

• SoundPowerIntensityResult
SoundPowerIntensityResult dataclass Scanning sound power.
• partial_power, partial_power_level
• sound_power, sound_power_level [dB] (NaN where negative_band)
• negative_band: per-band bool (True where P ≤ 0)
• surface_pressure_intensity_index (FpI)
• negative_partial_power_index (F+/-)
• repeatability, dynamic_capability_index (Ld)
• achieved_grade
• surface_area, sound_power_level_a, grade
ir.sound_power_level, ir.achieved_grade
absorption_area function Equivalent absorption area (ISO 354 Eq. 5/7).
• t60: T [s]
• volume V [m³]
• temperature [°C] (Default: 20)
• speed_of_sound [m/s] (overrides temperature)
• m: air attenuation [1/m] (Default: 0)
A = absorption_area(t60, volume=200)

• A [m²]
absorption_coefficient function Sound absorption coefficient (ISO 354 Eq. 9).
• t1, t2: empty / with-specimen T [s]
• volume V [m³]
• sample_area S [m²]
• temperature1/temperature2 [°C]
• speed_of_sound1/2, m1/m2
a = absorption_coefficient(t1, t2, 200, 10.8)

• α_s (unclamped, may exceed 1)
attenuation_from_alpha function ISO 9613-1 α → m (ISO 354 8.1.2.1).
• alpha: attenuation [dB/m]
m = attenuation_from_alpha(0.01)

• m = α/(10 lg e) [1/m]
SoundPowerWarning warning class ISO 3744/3746/3741/9614-2 qualification issue.
Emitted when the background margin is below the criterion, K2 exceeds the validity limit, a band's power is negative, or the room fails qualification; levels are then upper bounds
warnings.simplefilter('error', SoundPowerWarning)
AbsorptionWarning warning class ISO 354 advisory.
Emitted for a room below 150 m³, a sample area outside 10-12 m², an out-of-range temperature, or a non-physical α_s ≤ 0; the result still returns
warnings.simplefilter('error', AbsorptionWarning)
.plot() method One-line canonical figure on every result object (soft matplotlib dependency).
Available on ZwickerLoudness, STIResult, RoomAcousticsResult, DecayCurve, WeightedRatingResult, ImpactRatingResult, SoundPowerResult, ReverberationSoundPowerResult, SoundPowerIntensityResult and IntensityResult.
• ax: existing Axes, or None to build a fresh figure (Default: None)
• returns the Matplotlib Axes (an array of Axes for multi-panel figures); never calls plt.show()
• needs matplotlib (pip install phonometry[plot])
res.plot()
decay_curve(ir, fs).plot()

Notes #

  • zero_phase=True (in OctaveFilterBank.filter and spectrogram) filters forward-backward (sosfiltfilt): no group delay, doubled effective attenuation, offline analysis only. Incompatible with stateful=True. The passband also narrows, lowering the measured broadband band level by ~0.2 to 0.3 dB per band (a pure in-band tone is unaffected); prefer forward filtering when the absolute band SPL must match single-pass conventions, and reserve zero-phase for when the temporal envelope matters (e.g. reverberation decay).
  • mode='peak' includes the filter's onset transient; a tone that starts abruptly can overshoot by ~1 dB. See Calibration and dBFS.
  • octavefilter() caches filter bank designs internally (32 entries), so repeated calls with the same parameters skip the design phase. For explicit control use OctaveFilterBank.